| Literature DB >> 18928568 |
Chantal H P de Koning1, Sylvia P van den Heuvel, J Bart Staal, Bouwien C M Smits-Engelsman, Erik J M Hendriks.
Abstract
BACKGROUND: Neck pain is a significant health problem in modern society. There is evidence to suggest that neck muscle strength is reduced in patients with neck pain. This article provides a critical analysis of the research literature on the clinimetric properties of tests to measure neck muscle strength or endurance in patients with non-specific neck pain, which can be used in daily practice.Entities:
Mesh:
Year: 2008 PMID: 18928568 PMCID: PMC2575213 DOI: 10.1186/1471-2474-9-142
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Checklist used for the assessment of clinimetric properties of the studies included in the review
| Clinimetric property | Definition | Criteria |
| Reproducibility | Degree to which repeated measurements in stable persons provide similar answers | K: nominal/ordinal data |
| Reliability | The extent to which patients can be distinguished from each other, despite measurement error | + Adequate design, method; intraobserver ICC > 0.85 or K > 0.41; interobserver ICC >0.70 or K>0.61 |
| Agreement | The ability to achieve the same value with repeated measurements | Limits of agreement, SEM or SDC are presented |
| Construct validity | The extent to which a test actually measures the concept or trait which is being measured | Pearson's R or Spearman Rho |
| Responsiveness | Ability of an instrument to detect important change over time in the concept being measured | Hypotheses were formulated and results are in agreement |
| Interpretability | The degree to which one can assign qualitative meaning to quantitative scores | Authors provided information on the interpretation of scores, MIC-defined Mean and SD scores before and after treatment |
* K = Kappa statistics; ICC = intraclass correlation coefficient, SEM = standard error of measurement, SDC = smallest detectable change, MIC = minimal important change, and SD = standard deviation
Summary of the quality assessment of the instruments
| Reliability | Agreement | Validity | Responsiveness | Interpretability | |
| Muscle endurance of short neck flexors | + | ? | ? | 0 | 0 |
| Manual muscle examination | ? | 0 | 0 | 0 | 0 |
| Craniocervical flexion test | - | ? | 0 | 0 | 0 |
| Dynamometer | ? | 0 | 0 | 0 | 0 |
| Timed weighted overhead test | ? | 0 | 0 | 0 | 0 |
| Cervical PILE test | + | ? | 0 | 0 | 0 |
+ Positive
? Doubtful
- Inadequate
0 No information