Literature DB >> 15040967

Reliability of ultrasonography for the cervical multifidus muscle in asymptomatic and symptomatic subjects.

Eythor Kristjansson1.   

Abstract

A test-retest and inter-tester study was designed to assess the reliability of ultrasonography to depict the size of the cervical multifidus muscle in asymptomatic and symptomatic subjects. Ten asymptomatic women (range 19-48 years) and 10 women with chronic whiplash associated disorder (WAD), grade II, (range 19-49 years), matched for height and weight participated. The women were imaged by ultrasonography on two separate occasions by two different testers. On each occasion the cross-sectional area (CSA), and the transverse versus the anterior-posterior dimensions (shape ratio) at the C4 level were measured. The repeated measurements of the CSA were plotted against their means to reveal the limit of agreement. Good agreement was found for the asymptomatic group measurements and the intra-tester agreement for the symptomatic group. The inter-tester agreement for the symptomatic group was questionable. The size of the multifidus muscle was significantly reduced in the symptomatic group ( P<0.05 ). The results indicate that loss of clarity of the fascial layer between the semispinalis cervicis muscle and the cervical multifidus muscle may be a diagnostic sign of muscle atrophy. Ultrasonography can be used to precisely measure the size of the cervical multifidus muscle at the C4-level in asymptomatic young female subjects; it is also reliable for symptomatic subjects if the same tester performs the measurements. Additional criteria are recommended to improve the inter-tester agreement for symptomatic subjects.

Entities:  

Mesh:

Year:  2004        PMID: 15040967     DOI: 10.1016/S1356-689X(03)00059-6

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  21 in total

1.  Recruitment of motor units in two fascicles of the semispinalis cervicis muscle.

Authors:  Jochen Schomacher; Jakob Lund Dideriksen; Dario Farina; Deborah Falla
Journal:  J Neurophysiol       Date:  2012-03-07       Impact factor: 2.714

2.  Ultrasonographic measurement of neck muscle recruitment: a preliminary investigation.

Authors:  Fabianna M R Jesus; Paulo H Ferreira; Manuela L Ferreira
Journal:  J Man Manip Ther       Date:  2008

3.  Reliability of a measurement method for the cross-sectional area of the longus colli using real-time ultrasound imaging.

Authors:  Cliona O'Riordan; Pepijn Van De Ven; John Nelson; Karen McCreesh; Amanda Clifford
Journal:  Ultrasound       Date:  2016-07-13

4.  Echo-intensity, fatty infiltration, and morphology ultrasound imaging assessment in healthy and whiplash associated disorders populations: an observational study.

Authors:  Juan Antonio Valera-Calero; Asis Al-Buqain-Ortega; José Luis Arias-Buría; César Fernández-de-Las-Peñas; Umut Varol; Ricardo Ortega-Santiago
Journal:  Eur Spine J       Date:  2021-07-04       Impact factor: 3.134

5.  THE COMPARISON OF THE LUMBAR MULTIFIDUS MUSCLES FUNCTION BETWEEN GYMNASTIC ATHLETES WITH SWAY-BACK POSTURE AND NORMAL POSTURE.

Authors:  Elnaz Mahdavie; Asghar Rezasoltani; Leila Simorgh
Journal:  Int J Sports Phys Ther       Date:  2017-08

6.  Efficacy of superficial cervical plexus block versus cervical retrolaminar block both combined with auriculotemporal nerve block in parotid surgeries.

Authors:  Ghada S Mohammed; Alaa M Mazy; Nahla S El-Ebahnasawy; Mohammed N Mohammed
Journal:  Ann Med Surg (Lond)       Date:  2022-03-02

7.  Estimation of musculotendon kinematics under controlled tendon indentation.

Authors:  Matthieu K Chardon; Yasin Y Dhaher; Nina I Suresh; Giselle Jaramillo; W Zev Rymer
Journal:  J Biomech       Date:  2015-08-07       Impact factor: 2.712

8.  Sex Differences in Ultrasound-Based Muscle Size and Mechanical Properties of the Cervical-Flexor and -Extensor Muscles.

Authors:  Takashi Nagai; Nathan D Schilaty; David A Krause; Eric M Crowley; Timothy E Hewett
Journal:  J Athl Train       Date:  2020-01-22       Impact factor: 2.860

9.  Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study.

Authors:  Leila Rahnama; Asghar Rezasoltani; Minoo Khalkhali-Zavieh; Behnam Rahnama; Farhang Noori-Kochi
Journal:  Braz J Phys Ther       Date:  2015-09-01       Impact factor: 3.377

10.  ULTRASONOGRAPHIC ASSESSMENT OF NECK MUSCULAR SIZE AND RANGE OF MOTION IN RUGBY PLAYERS.

Authors:  Walter Hemelryck; Josselin Calistri; Virginie Papadopoulou; Sigrid Theunissen; Christian Dugardeyn; Costantino Balestra
Journal:  Int J Sports Phys Ther       Date:  2018-02
View more