Literature DB >> 18922423

Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions.

Giorgio Della Rocca1, Maria Gabriella Costa, Paolo Chiarandini, Gaia Bertossi, Manuela Lugano, Livia Pompei, Cecilia Coccia, Mauricio Sainz-Barriga, Paolo Pietropaoli.   

Abstract

OBJECTIVE: This study aimed to compare continuous cardiac output (CCO) obtained using the arterial pulse wave (APCO) measurement with a simultaneous measurement of the intermittent cardiac output (ICO) and CCO obtained with a pulmonary artery catheter (PAC) in liver transplant patients.
DESIGN: A prospective, single-center evaluation.
SETTING: A university hospital intensive care unit. PATIENTS: Eighteen patients after liver transplantation.
INTERVENTIONS: Pulmonary artery catheters were placed in all patients, and ICO and CCO were determined using thermodilution. APCO measurements were made with the Vigileo System (Edwards Lifesciences, Irvine, CA).
MEASUREMENTS AND MAIN RESULTS: The authors obtained 126 data pairs of ICO and APCO and 864 pairs of CCO and APCO. ICO data were collected after intensive care unit admission and every 8 hours until the 48th postoperative hour. CCO and APCO data were collected every hour from admission until the 48th postoperative hour. Bias and precision were 0.95 +/- 1.41 L/min for ICO versus APCO and 1.29 +/- 1.28 L/min for CCO and APCO. Bias and precision for cardiac output (CO) data pairs less than 8 L/min were 0.32 +/- 1.14 L/min between ICO and APCO and 0.71 +/- 0.98 L/min between CCO and APCO. For CO data pairs higher than 8 L/min, bias and precision were 1.79 +/- 1.54 L/min between ICO and APCO and 2.25 +/- 1.14 L/min between CCO and APCO.
CONCLUSIONS: APCO enables the assessment of CO with clinically acceptable bias and precision. At higher CO levels, APCO underestimates PAC measurements and it is not as reliable as thermodilution in hyperdynamic liver transplant patients.

Entities:  

Mesh:

Year:  2008        PMID: 18922423     DOI: 10.1053/j.jvca.2008.02.021

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  14 in total

1.  Can the "FloTrac" really track flow in septic patients?

Authors:  Xavier Monnet; Daniel Lahner
Journal:  Intensive Care Med       Date:  2010-12-10       Impact factor: 17.440

2.  Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution.

Authors:  Matthew Lee; Laurence Weinberg; Brett Pearce; Nicholas Scurrah; David A Story; Param Pillai; Peter R McCall; Larry P McNicol; Philip J Peyton
Journal:  J Clin Monit Comput       Date:  2016-02-16       Impact factor: 2.502

Review 3.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

Review 4.  Hemodynamic monitoring during liver transplantation: A state of the art review.

Authors:  Mona Rezai Rudnick; Lorenzo De Marchi; Jeffrey S Plotkin
Journal:  World J Hepatol       Date:  2015-06-08

5.  Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo.

Authors:  Sophie Marqué; Antoine Gros; Loic Chimot; Arnaud Gacouin; Sylvain Lavoué; Christophe Camus; Yves Le Tulzo
Journal:  J Clin Monit Comput       Date:  2013-01-30       Impact factor: 2.502

6.  Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock.

Authors:  Cornelis Slagt; Marcel A de Leeuw; Jan Beute; Emmy Rijnsburger; Martijn Hoeksema; Jan W R Mulder; Ignacio Malagon; A B Johan Groeneveld
Journal:  J Clin Monit Comput       Date:  2012-11-15       Impact factor: 2.502

7.  Influence of tidal volume for stroke volume variation to predict fluid responsiveness in patients undergoing one-lung ventilation.

Authors:  Koichi Suehiro; Ryu Okutani
Journal:  J Anesth       Date:  2011-07-09       Impact factor: 2.078

8.  Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients.

Authors:  Daniel De Backer; Gernot Marx; Andrew Tan; Christopher Junker; Marc Van Nuffelen; Lars Hüter; Willy Ching; Frédéric Michard; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2010-12-10       Impact factor: 17.440

9.  Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices.

Authors:  Xavier Monnet; Nadia Anguel; Brice Naudin; Julien Jabot; Christian Richard; Jean-Louis Teboul
Journal:  Crit Care       Date:  2010-06-10       Impact factor: 9.097

10.  Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo-derived cardiac output measurements: a prospective comparison study.

Authors:  Savvas Eleftheriadis; Zisis Galatoudis; Vasilios Didilis; Ioannis Bougioukas; Julika Schön; Hermann Heinze; Klaus-Ulrich Berger; Matthias Heringlake
Journal:  Crit Care       Date:  2009-11-09       Impact factor: 9.097

View more