Chemical shift artifact: dependence on shape and orientation of the lipid-water interface.

R C Smith1, R C Lange, S M McCarthy.   

Abstract

On magnetic resonance images, chemical shift artifact (CSA) can be seen at a planar lipid-water interface oriented within the plane of the phase-encoding and section-select directions (ie, perpendicular to the frequency-encoding direction). Phantoms and a clinical case were used to demonstrate that when a lipid-water interface is curvilinear (eg, spherical) or planar but not oriented along the section-select direction, CSA may be absent or diminished. This effect can be seen at interfaces of normal structures (kidneys, bladder) as well as at interfaces with pathologic lesions such as lipid-containing dermoids. Not only is this effect dependent on section thickness, field of view, matrix size, and receiver bandwidth, but it is also strongly dependent on the orientation of the interface with respect to the section-select direction. Knowledge of the factors that can alter CSA is important since it is used to distinguish lipid-containing from nonlipid-containing structures of similar signal intensities.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1887036     DOI: 10.1148/radiology.181.1.1887036

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  Post-processing water-fat imaging technique for fat suppression in a low-field MR imaging system, evaluation in patients with rheumatoid arthritis.

Authors:  Kari Palosaari; Osmo Tervonen
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

2.  Body MRI artefacts: from image degradation to diagnostic utility.

Authors:  G Rescinito; C Sirlin; G Cittadini
Journal:  Radiol Med       Date:  2008-10-04       Impact factor: 3.469

3.  Intracranial Migration of Intravitreal Silicone Oil: A Case Report.

Authors:  H Kim; H S Hong; J Park; A L Lee
Journal:  Clin Neuroradiol       Date:  2015-02-27       Impact factor: 3.649

4.  Fat suppression in magnetic resonance imaging of the head and neck region: is the two-point DIXON technique superior to spectral fat suppression?

Authors:  Christina M Wendl; Johannes Eiglsperger; Lena-Marie Dendl; Harald Brodoefel; Karl-Michael Schebesch; Christian Stroszczynski; Claudia Fellner
Journal:  Br J Radiol       Date:  2018-02-23       Impact factor: 3.039

5.  MRI of silicone vitreous ocular implants with phantom correlation.

Authors:  C Bash; M Rothman; M Hamet; D Sorce; G Zoarski; F Mihara; Y Numaguchi
Journal:  Neuroradiology       Date:  1995-05       Impact factor: 2.804

6.  Improved fat suppression using multipeak reconstruction for IDEAL chemical shift fat-water separation: application with fast spin echo imaging.

Authors:  Richard Kijowski; Michael A Woods; Kenneth S Lee; Kuya Takimi; Huanzhou Yu; Ann Shimakawa; Jean H Brittain; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2009-02       Impact factor: 4.813

7.  Updates in MRI characterization of the thymus in myasthenic patients.

Authors:  G A Popa; E M Preda; C Scheau; C Vilciu; I G Lupescu
Journal:  J Med Life       Date:  2012-06-18

8.  QC-Automator: Deep Learning-Based Automated Quality Control for Diffusion MR Images.

Authors:  Zahra Riahi Samani; Jacob Antony Alappatt; Drew Parker; Abdol Aziz Ould Ismail; Ragini Verma
Journal:  Front Neurosci       Date:  2020-01-22       Impact factor: 4.677

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.