Head holder for PET, CT, and MR studies.

V Bettinardi1, R Scardaoni, M C Gilardi, G Rizzo, D Perani, E Paulesu, G Striano, F Triulzi, F Fazio.   

Abstract

A new head holder for the fixation and repositioning of the patient head in PET, CT, and MR scanners has been designed and tested. With this device, a bidimensional correlation between functional and anatomical brain images can also be obtained. Head fixation and repositioning are achieved using the patient's dental morphology as an anatomical reference. With a dentistic material, a mold of the patient's teeth is obtained in a few minutes. The molding substance rests on a plastic support, fixed to the head holder. Each time the patient undergoes a new study, his/her personal mold is used, ensuring accurate head repositioning. External markers fixed on the head holder (made visible in lateral PET and CT projection images, midsaggital MR images, and also on the axial images) make it possible to record and recognize the angular orientation and the position of the brain in the three-dimensional space, to correlate images of the same patient obtained with different neuroimaging modalities, and to accurately reposition patients for follow-up studies. The head holder was tested on several subjects. Fixation and repositioning accuracy of within 2.5 mm were achieved in the three-dimensional space. Orientation accuracy was 1 degree.

Entities:  

Mesh:

Year:  1991        PMID: 1885820     DOI: 10.1097/00004728-199109000-00034

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  9 in total

1.  Quantification of fMRI artifact reduction by a novel plaster cast head holder.

Authors:  V Edward; C Windischberger; R Cunnington; M Erdler; R Lanzenberger; D Mayer; W Endl; R Beisteiner
Journal:  Hum Brain Mapp       Date:  2000-11       Impact factor: 5.038

Review 2.  A review of the automated detection of change in serial imaging studies of the brain.

Authors:  Julia Patriarche; Bradley Erickson
Journal:  J Digit Imaging       Date:  2004-06-29       Impact factor: 4.056

3.  Localization of grasp representations in humans by PET: 1. Observation versus execution.

Authors:  G Rizzolatti; L Fadiga; M Matelli; V Bettinardi; E Paulesu; D Perani; F Fazio
Journal:  Exp Brain Res       Date:  1996-09       Impact factor: 1.972

Review 4.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

Review 5.  Prospective motion correction in functional MRI.

Authors:  Maxim Zaitsev; Burak Akin; Pierre LeVan; Benjamin R Knowles
Journal:  Neuroimage       Date:  2016-11-11       Impact factor: 6.556

6.  External reference markers for the correction of head rotation in brain single-photon emission tomography.

Authors:  W D Leslie; A Borys; D McDonald; J O Dupont; A E Peterdy
Journal:  Eur J Nucl Med       Date:  1995-04

7.  A hybrid method of attenuation correction for positron emission tomography brain studies.

Authors:  V Bettinardi; M C Gilardi; S Cargnel; G Rizzo; M Teräs; G Striano; F Fazio
Journal:  Eur J Nucl Med       Date:  1994-12

8.  Behavioral interventions for reducing head motion during MRI scans in children.

Authors:  Deanna J Greene; Jonathan M Koller; Jacqueline M Hampton; Victoria Wesevich; Andrew N Van; Annie L Nguyen; Catherine R Hoyt; Lindsey McIntyre; Eric A Earl; Rachel L Klein; Joshua S Shimony; Steven E Petersen; Bradley L Schlaggar; Damien A Fair; Nico U F Dosenbach
Journal:  Neuroimage       Date:  2018-01-12       Impact factor: 6.556

9.  Active head motion reduction in magnetic resonance imaging using tactile feedback.

Authors:  Florian Krause; Caroline Benjamins; Judith Eck; Michael Lührs; Rick van Hoof; Rainer Goebel
Journal:  Hum Brain Mapp       Date:  2019-06-09       Impact factor: 5.038

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.