Literature DB >> 18854579

Automated image analysis of cytokinesis-blocked micronuclei: an adapted protocol and a validated scoring procedure for biomonitoring.

Ilse Decordier1, Alexander Papine, Gina Plas, Sam Roesems, Kim Vande Loock, Jennifer Moreno-Palomo, Eduardo Cemeli, Diana Anderson, Aleksandra Fucic, Ricardo Marcos, Françoise Soussaline, Micheline Kirsch-Volders.   

Abstract

Micronuclei (MN) frequencies in peripheral blood lymphocytes have been used worldwide as a biomarker of chromosomal damage for genotoxicity testing and biomonitoring studies. Automation of MN analysis would provide faster and more reliable results with minimizing subjective MN identification. We developed an automated facility for the scoring of the in vitro MN cytokinesis-block assay for biomonitoring on Giemsa-stained slides, fulfilling the following criteria: applicable to the cytokinesis-block micronucleus methodology, discriminating between mono-, bi- and polynucleated cells, MN scoring according to HUMN scoring criteria, false-negative MN rate <10% and false-positive (FP) MN rate <1%. We first adapted the slide preparation protocol to obtain an optimal cell density and dispersion, which is important for image analysis. We developed specific algorithms starting from the cell as a detection unit. The whole detection and scoring process was separated into two distinct steps: in the first step, the cells and nuclei are detected; then, in the second step, the MN are searched for in the detected cells. Since the rate of FP MN obtained by the automatic analysis was in the range of 0.5-1.5%, an interactive visual validation step was introduced, which is not time consuming and allows quality control. Validation of the automated scoring procedure was undertaken by comparing the results of visual and automated scoring of micronucleated mono- and binucleated cells in human lymphocytes induced by two clastogens (ionizing radiation and methyl methane-sulphonate), two aneugens (nocodazole and carbendazim) and one apoptogen (staurosporine). Although the absolute MN frequencies obtained with automated scoring were lower as compared to those detected by visual scoring, a clear dose response for MNBN frequencies was observed with the automated scoring system, indicating that it is able to produce biologically relevant and reliable results. These observations, together with its ability to detect cells, nuclei and MN in accordance with the HUMN scoring criteria, confirm the usability of the automated MN analysis system for biomonitoring.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18854579     DOI: 10.1093/mutage/gen057

Source DB:  PubMed          Journal:  Mutagenesis        ISSN: 0267-8357            Impact factor:   3.000


  28 in total

Review 1.  Laser scanning cytometry for automation of the micronucleus assay.

Authors:  Zbigniew Darzynkiewicz; Piotr Smolewski; Elena Holden; Ed Luther; Mel Henriksen; Maxime François; Wayne Leifert; Michael Fenech
Journal:  Mutagenesis       Date:  2011-01       Impact factor: 3.000

Review 2.  Radiation signature on exposed cells: Relevance in dose estimation.

Authors:  Venkatachalam Perumal; Tamizh Selvan Gnana Sekaran; Venkateswarlu Raavi; Safa Abdul Syed Basheerudeen; Karthik Kanagaraj; Amith Roy Chowdhury; Solomon Fd Paul
Journal:  World J Radiol       Date:  2015-09-28

3.  American Ginseng Modifies Cs-Induced DNA Damage and Oxidative Stress in Human Lymphocytes.

Authors:  Tung-Kwang Lee; Kevin F O'Brien; Weidong Wang; Chao Sheng; Tao Wang; Roberta M Johnke; Ron R Allison
Journal:  Open Nucl Med J       Date:  2009-01-01

4.  Fast image analysis for the micronucleus assay in a fully automated high-throughput biodosimetry system.

Authors:  Oleksandra V Lyulko; Guy Garty; Gerhard Randers-Pehrson; Helen C Turner; Barbara Szolc; David J Brenner
Journal:  Radiat Res       Date:  2014-02-06       Impact factor: 2.841

Review 5.  Micronuclei in neonates and children: effects of environmental, genetic, demographic and disease variables.

Authors:  Nina Holland; Alexandra Fucic; Domenico Franco Merlo; Radim Sram; Micheline Kirsch-Volders
Journal:  Mutagenesis       Date:  2011-01       Impact factor: 3.000

6.  Maternal diet during pregnancy and micronuclei frequency in peripheral blood T lymphocytes in mothers and newborns (Rhea cohort, Crete).

Authors:  Cristina O'Callaghan-Gordo; Manolis Kogevinas; Marie Pedersen; Eleni Fthenou; Ana Espinosa; Xristina Tsiapa; Georgia Chalkiadaki; Vasiliki Daraki; Eirini Dermitzaki; Ilse Decordier; Peter B Farmer; Panagiotis Georgiadis; Vaggelis Georgiou; Soterios A Kyrtopoulos; Domenico Franco Merlo; Dora Romaguera; Theano Roumeliotaki; Katerina Sarri; Margareta Törnqvist; Kim Vande Loock; Hans von Stedingk; Jos Kleinjans; Micheline Kirsch-Volders; Leda Chatzi
Journal:  Eur J Nutr       Date:  2016-09-21       Impact factor: 5.614

7.  The RABIT: a rapid automated biodosimetry tool for radiological triage.

Authors:  Guy Garty; Youhua Chen; Alessio Salerno; Helen Turner; Jian Zhang; Oleksandra Lyulko; Antonella Bertucci; Yanping Xu; Hongliang Wang; Nabil Simaan; Gerhard Randers-Pehrson; Y Lawrence Yao; Sally A Amundson; David J Brenner
Journal:  Health Phys       Date:  2010-02       Impact factor: 1.316

8.  Assessment of biodosimetry methods for a mass-casualty radiological incident: medical response and management considerations.

Authors:  Julie M Sullivan; Pataje G S Prasanna; Marcy B Grace; Lynne K Wathen; Rodney L Wallace; John F Koerner; C Norman Coleman
Journal:  Health Phys       Date:  2013-12       Impact factor: 1.316

9.  The in vitro micronucleus assay using imaging flow cytometry and deep learning.

Authors:  Matthew A Rodrigues; Christine E Probst; Artiom Zayats; Bryan Davidson; Michael Riedel; Yang Li; Vidya Venkatachalam
Journal:  NPJ Syst Biol Appl       Date:  2021-05-18

10.  Seven benzimidazole pesticides combined at sub-threshold levels induce micronuclei in vitro.

Authors:  Sibylle Ermler; Martin Scholze; Andreas Kortenkamp
Journal:  Mutagenesis       Date:  2013-04-01       Impact factor: 3.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.