Abstract

BACKGROUND AND
PURPOSE: To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols.
MATERIALS AND METHODS: Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05.
RESULTS: The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens.
CONCLUSIONS: Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.

Mesh:

Year:  2008        PMID: 18854441     DOI: 10.3174/ajnr.A1327

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  7 in total

Review 1.  Multicentre imaging measurements for oncology and in the brain.

Authors:  P S Tofts; D J Collins
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Data analysis of low dose multislice helical CT scan in orbital trauma.

Authors:  Ji-Wei Wang; Chong Tang; Bo-Rong Pan
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

3.  Signal-to-noise ratio and dose to the lens of the eye for computed tomography examination of the brain using an automatic tube current modulation system.

Authors:  Supawitoo Sookpeng; Chitsanupong Butdee
Journal:  Emerg Radiol       Date:  2016-12-02

4.  Clinical evaluation of a dose monitoring software tool based on Monte Carlo Simulation in assessment of eye lens doses for cranial CT scans.

Authors:  Nika Guberina; Saravanabavaan Suntharalingam; Kai Naßenstein; Michael Forsting; Jens Theysohn; Axel Wetter; Adrian Ringelstein
Journal:  Neuroradiology       Date:  2016-07-20       Impact factor: 2.804

5.  Optimization of patient dose and image quality with z-axis dose modulation for computed tomography (CT) head in acute head trauma and stroke.

Authors:  T Thomas Zacharia; Sangam G Kanekar; Dan T Nguyen; Kevin Moser
Journal:  Emerg Radiol       Date:  2010-09-21

6.  Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging.

Authors:  Mathias Meyer; Holger Haubenreisser; Rainer Raupach; Bernhard Schmidt; Florian Lietzmann; Christianne Leidecker; Thomas Allmendinger; Thomas Flohr; Lothar R Schad; Stefan O Schoenberg; Thomas Henzler
Journal:  Eur Radiol       Date:  2014-09-08       Impact factor: 5.315

7.  MRI-based radiotherapy planning method using rigid image registration technique combined with outer body correction scheme: a feasibility study.

Authors:  Ki Mun Kang; Hoon Sik Choi; Bae Kwon Jeong; Jin Ho Song; In-Bong Ha; Yun Hee Lee; Chul Hang Kim; Hojin Jeong
Journal:  Oncotarget       Date:  2017-05-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.