Literature DB >> 18853107

Comparison of peristaltic and Venturi pumps in bimanual microincisional cataract surgery.

Hande Karaguzel1, Aylin Karalezli, Bekir Sitki Aslan.   

Abstract

Comparison of peristaltic and Venturi pumps in bimanual microincision phacoemulsification on the success of the cataract surgery by using sleeveless phaco tip. Bimanual microincision phacoemulsification was done in 49 eyes using a 1.4-mm temporal clear corneal incision. A peristaltic pump was used in 23 eyes, and a Venturi pump was used in 26 eyes for phacoemulsification. Intraoperative complications, anterior chamber stability, and mean duration of surgery were recorded. Duration of surgery was shorter in the Venturi pump group. Anterior chamber stability could not be established in 17 eyes in the peristaltic pump group; it was established in all eyes in the Venturi pump group. Corneal burns were observed in two eyes in the peristaltic pump group and no eyes in the Venturi pump group. Use of a Venturi pump system and a vented gas-forced infusion system can significantly shorten surgery time and reduce risk of thermal burns.

Entities:  

Mesh:

Year:  2008        PMID: 18853107     DOI: 10.1007/s10792-008-9267-6

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  9 in total

1.  Phakonit: phacoemulsification through a 0.9 mm corneal incision.

Authors:  A Agarwal; A Agarwal; S Agarwal; P Narang; S Narang
Journal:  J Cataract Refract Surg       Date:  2001-10       Impact factor: 3.351

2.  Feasibility of ultrasound cataract surgery with a 1.4 mm incision.

Authors:  H Tsuneoka; T Shiba; Y Takahashi
Journal:  J Cataract Refract Surg       Date:  2001-06       Impact factor: 3.351

3.  Ultrasmall-incision bimanual phacoemulsification and AcrySof SA30AL implantation through a 2.2 mm incision.

Authors:  Hiroshi Tsuneoka; Ayako Hayama; Michiko Takahama
Journal:  J Cataract Refract Surg       Date:  2003-06       Impact factor: 3.351

4.  Anterior vented gas forced infusion system of the Accurus surgical system in phakonit.

Authors:  Arturo Pérez-Arteaga
Journal:  J Cataract Refract Surg       Date:  2004-04       Impact factor: 3.351

5.  Thermal effect on corneal incisions with different phacoemulsification ultrasonic tips.

Authors:  H Bissen-Miyajima; S Shimmura; K Tsubota
Journal:  J Cataract Refract Surg       Date:  1999-01       Impact factor: 3.351

6.  Clinical results of endocapsular phacoemulsification and complete in-the-bag intraocular lens fixation.

Authors:  T Hara; T Hara
Journal:  J Cataract Refract Surg       Date:  1987-05       Impact factor: 3.351

7.  Dodick photolysis for cataract surgery: early experience with the Q-switched neodymium: YAG laser in 100 consecutive patients.

Authors:  A J Kanellopoulos; J M Dodick; P Brauweiler; E Alzner
Journal:  Ophthalmology       Date:  1999-11       Impact factor: 12.079

8.  Preventing incision burn during phacoemulsification.

Authors:  R J Mackool
Journal:  J Cataract Refract Surg       Date:  1994-05       Impact factor: 3.351

9.  Ultrasonic phacoemulsification using a 1.4 mm incision: clinical results.

Authors:  Hiroshi Tsuneoka; Takuya Shiba; Yoko Takahashi
Journal:  J Cataract Refract Surg       Date:  2002-01       Impact factor: 3.351

  9 in total
  2 in total

1.  Long-Term Variations in Retinal Parameters after Uncomplicated Cataract Surgery.

Authors:  Maciej Gawęcki; Natalia Prądzyńska; Izabella Karska-Basta
Journal:  J Clin Med       Date:  2022-06-15       Impact factor: 4.964

2.  Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine.

Authors:  Wilson Takashi Hida; André Lins de Medeiros; André Gustavo de Araújo Rolim; Antonio Francisco Pimenta Motta; Danilo Varela Kniggendorf; Rodrigo Lafetá Franco de Queiroz; Mário Augusto Pereira Dias Chaves; Pedro Carlos Carricondo; Celso Takashi Nakano; Walton Nosé
Journal:  Clin Ophthalmol       Date:  2018-12-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.