Literature DB >> 1884475

Diagnostic accuracy of thallium-201 myocardial perfusion imaging.

G A Beller1.   

Abstract

Myocardial thallium-201 (Tl-201) imaging performed in conjunction with exercise stress has enhanced the accuracy of detecting coronary artery disease among patients with chest pain. Sensitivity and specificity of qualitative visual Tl-201 scintigraphy for detection of coronary artery disease average 84% and 87%, respectively. Quantitative analysis of planar Tl-201 scintigrams has yielded sensitivity and specificity in the 90% range. Single photon emission computed tomographic imaging is associated with even higher sensitivity but with specificity in the 82-85% range. Perfusion defects representing ischemia can now be distinguished from scar by demonstration of delayed Tl-201 redistribution or enhanced uptake after reinjection of a second dose of Tl-201. Stenoses of the left circumflex coronary artery are less easily detected than lesions of the right and left anterior descending coronary arteries. False-positive Tl-201 perfusion defects may occur as a result of attenuation artifacts, most often caused by overlying breast tissue or by a high left hemidiaphragm. Patient motion during acquisition of single photon emission computed tomographic images results in artifactual defects on reconstruction. Abnormal Tl-201 uptake has been noted in patients with 1) left bundle branch block and normal coronary arteries, 2) hypertrophic cardiomyopathy, and 3) progressive systemic sclerosis.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1884475

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  8 in total

1.  Attenuation smear: a 'paradoxical' increase in counts due to attenuation artifact.

Authors:  C L Hansen; M Kramer
Journal:  Int J Card Imaging       Date:  2000-12

2.  Prognostic value of adenosine stress cardiovascular magnetic resonance and dobutamine stress echocardiography in patients with low-risk chest pain.

Authors:  Gregory Hartlage; Matthew Janik; Athanasios Anadiotis; Emir Veledar; John Oshinski; Dimitrios Kremastinos; Arthur Stillman; Stamatios Lerakis
Journal:  Int J Cardiovasc Imaging       Date:  2011-05-12       Impact factor: 2.357

3.  Enhanced accuracy of defect detection by myocardial single-photon emission computed tomography with attenuation correction with gadolinium 153 line sources: evaluation with a cardiac phantom.

Authors:  Z X He; M D Scarlett; J J Mahmarian; M S Verani
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

4.  Assessment of the severity of coronary artery stenosis by the ratio of the regional washout rate determined by adenosine triphosphate stress Tl-201 SPECT.

Authors:  H Teragawa; T Yamagata; M Kato; M Hiraga; H Matsuura; G Kajiyama
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

5.  Lower accuracy of TI-201 SPECT in women is not improved by size-based normal databases or Wiener filtering.

Authors:  C L Hansen; M Kramer; A Rastogi
Journal:  J Nucl Cardiol       Date:  1999 Mar-Apr       Impact factor: 5.952

6.  Incremental diagnostic value of dipyridamole echocardiography and exercise thallium 201 scintigraphy in the assessment of presence and extent of coronary artery disease.

Authors:  V Di Bello; E Gori; C R Bellina; O Parodi; N Molea; G Santoro; G Mariani; U Conti; E Magagnini; P Marzullo
Journal:  J Nucl Cardiol       Date:  1994 Jul-Aug       Impact factor: 5.952

7.  Prognostic value of myocardial hypoperfusion indexes in patients with suspected or known coronary artery disease.

Authors:  M Petretta; A Cuocolo; A Carpinelli; E Nicolai; G Valva; V Bianchi; L Salemme; M Salvatore; D Bonaduce
Journal:  J Nucl Cardiol       Date:  1994 Jul-Aug       Impact factor: 5.952

8.  Prognostic value of adenosine stress cardiovascular magnetic resonance in patients with low-risk chest pain.

Authors:  Stamatios Lerakis; Dalton S McLean; Athanasios V Anadiotis; Matthew Janik; John N Oshinski; Nikolaos Alexopoulos; Elisa Zaragoza-Macias; Emir Veledar; Arthur E Stillman
Journal:  J Cardiovasc Magn Reson       Date:  2009-09-21       Impact factor: 5.364

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.