Literature DB >> 18842754

Endovascular coiling of cerebral aneurysms using "bioactive" or coated-coil technologies: a systematic review of the literature.

P M White1, J Raymond.   

Abstract

SUMMARY: Second-generation coils have been available since 2002. We wanted to assess their performance and appraise available evidence. Therefore we performed a systematic review of the literature from 2002 to 2007. There were 27 studies with a total of 2390 patients that met pre-specified inclusion criteria. All studies were classed as having a high risk of bias. There were no randomized trials and for most studies results were not independently assessed and follow-up periods were short (mean 7 months). There were large differences in demographic and aneurysm characteristics, making comparisons between coil cohorts difficult. Procedure-related morbidity and mortality were similar for all coil types. Hemorrhagic events during follow-up were few, in the range of 1%/year for all coil types. The available literature is of poor quality and clinical series provide very little evidence in favor of second-generation coils. Positive randomized trial results are needed to justify routine clinical use. This systematic review illustrates the failure of the industry, the regulatory authorities, and the neurointerventional community combined to provide a reliable and prudent approach to the introduction of new devices.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18842754     DOI: 10.3174/ajnr.A1324

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  16 in total

Review 1.  Review of 2 decades of aneurysm-recurrence literature, part 1: reducing recurrence after endovascular coiling.

Authors:  E Crobeddu; G Lanzino; D F Kallmes; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

2.  GREAT-a randomized aneurysm trial. Design of a randomized controlled multicenter study comparing HydroSoft/HydroFrame and bare platinum coils for endovascular aneurysm treatment.

Authors:  Christian Taschner; René Chapot; Vincent Costalat; Patrick Courthéoux; Xavier Barreau; Jerome Berge; Laurent Pierot; Kryzsztof Kadziolka; Betty Jean; Raphael Blanc; Alessandra Biondi; Hervé Brunel; Sophie Gallas; Ansgar Berlis; Denis Herbreteau; Joachim Berkefeld; Christoph Groden; Horst Urbach; Samer El Shikh; Erika Graf; Alain Bonafé
Journal:  Neuroradiology       Date:  2015-02-28       Impact factor: 2.804

3.  Endovascular treatment of intracranial aneurysms with flow-diverter stents: preliminary single-centre experience.

Authors:  Emanuele Malatesta; Nunzio Paolo Nuzzi; Ignazio Divenuto; Rita Fossaceca; Mariangela Lombardi; Paolo Cerini; Giuseppe Guzzardi; Alessandro Stecco; Cosma Andreula; Alessandro Carriero
Journal:  Radiol Med       Date:  2013-06-26       Impact factor: 3.469

4.  Evaluation of the characteristics of various types of coils for the embolization of intracranial aneurysms with an optical pressure sensor system.

Authors:  Noriaki Matsubara; Shigeru Miyachi; Yoshitaka Nagano; Tomotaka Ohshima; Osamu Hososhima; Takashi Izumi; Arihito Tsurumi; Toshihiko Wakabayashi; Akihito Sano; Hideo Fujimoto
Journal:  Neuroradiology       Date:  2010-06-03       Impact factor: 2.804

5.  The Orbit Galaxy XTRASOFT Coils: A Multicenter Study of Coil Safety and Efficacy in Both Ruptured and Unruptured Cerebral Aneurysms.

Authors:  Ahmad Khaldi; Kyle M Fargen; Ben Waldau; Adnan H Siddiqui; Brian L Hoh; William Mack; Jeffrey Carpenter; Erol Veznedaroglu; J Mocco
Journal:  J Vasc Interv Neurol       Date:  2012-06

6.  Embolization of intracranial aneurysms with HydroSoft coils: results of the Korean multicenter study.

Authors:  J H Park; H-S Kang; M H Han; P Jeon; D-S Yoo; T H Lee
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-15       Impact factor: 3.825

Review 7.  Endovascular treatment of ruptured intracranial aneurysms.

Authors:  Michael T Froehler
Journal:  Curr Neurol Neurosci Rep       Date:  2013-02       Impact factor: 5.081

8.  HydroCoils, occlusion rates, and outcomes: a large single-center study.

Authors:  A M O'Hare; N F Fanning; J P Ti; R Dunne; P R Brennan; J M Thornton
Journal:  AJNR Am J Neuroradiol       Date:  2010-08-12       Impact factor: 3.825

9.  Quantification of recurrence volumes after endovascular treatment of cerebral aneurysm as surrogate endpoint for treatment stability.

Authors:  Thorsten Ries; Karl Wegscheider; Asmus Wulff; Kristin Radelfahr; Dennis Säring; Nils Daniel Forkert; Jens Fiehler
Journal:  Neuroradiology       Date:  2010-09-17       Impact factor: 2.804

10.  Patients prone to recurrence after endovascular treatment: periprocedural results of the PRET randomized trial on large and recurrent aneurysms.

Authors:  J Raymond; R Klink; M Chagnon; S L Barnwell; A J Evans; J Mocco; B L Hoh; A S Turk; R D Turner; H Desal; D Fiorella; S Bracard; A Weill; F Guilbert; D Roy
Journal:  AJNR Am J Neuroradiol       Date:  2014-06-19       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.