Literature DB >> 25724881

GREAT-a randomized aneurysm trial. Design of a randomized controlled multicenter study comparing HydroSoft/HydroFrame and bare platinum coils for endovascular aneurysm treatment.

Christian Taschner1, René Chapot, Vincent Costalat, Patrick Courthéoux, Xavier Barreau, Jerome Berge, Laurent Pierot, Kryzsztof Kadziolka, Betty Jean, Raphael Blanc, Alessandra Biondi, Hervé Brunel, Sophie Gallas, Ansgar Berlis, Denis Herbreteau, Joachim Berkefeld, Christoph Groden, Horst Urbach, Samer El Shikh, Erika Graf, Alain Bonafé.   

Abstract

The effectiveness of a hybrid hydrogel platinum detachable coil (HydroCoil; MicroVention Inc., Tustin, CA) for endovascular aneurysm treatment has been proven in a recently published RCT. Due to technical restrictions (coil stiffness, time restriction for placement), the HydroSoft coil as well as a corresponding 3D framing coil, the HydroFrame coil (MicroVention Inc., Tustin, CA), a class of new softer coils containing less hydrogel and swelling more slowly than the HydroCoil, have been developed and brought to clinical practice. The present study aims to compare the effectiveness of endovascular aneurysm treatment with coil embolization between patients allocated HydroSoft/HydroFrame versus bare platinum coiling. GREAT is a randomized, controlled, multicentre trial in patients bearing cerebral aneurysms to be treated by coil embolization. Eligible patients were randomized to either coil embolization with HydroSoft/HydroFrame coils (>50 % of administered coil length), or bare platinum coils. Inclusion criteria were as follows: age 18-75, ruptured aneurysm (WFNS 1-3) and unruptured aneurysm with a diameter between 4 and 12 mm. Anatomy such that endovascular coil occlusion deemed possible and willingness of the neurointerventionalist to use either HydroSoft/HydroFrame or bare platinum coils. Exclusion criteria were as follows: aneurysms previously treated by coiling or clipping. Primary endpoint is a composite of major aneurysm recurrence on follow-up angiography and poor clinical outcome (modified Rankin scale 3 or higher), both assessed at 18 months post treatment. Risk differences for poor outcomes will be estimated in a modified intention-to-treat analysis stratified by rupture status (DRKS-ID: DRKS00003132).

Entities:  

Mesh:

Year:  2015        PMID: 25724881     DOI: 10.1007/s00234-015-1501-0

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  16 in total

1.  HydroSoft coil versus HydroCoil for endovascular aneurysm occlusion study: a single center experience.

Authors:  Xin-Bin Guo; Yi-Mu Fan; Jian-Ning Zhang
Journal:  Eur J Radiol       Date:  2010-05-26       Impact factor: 3.528

Review 2.  Endovascular coiling of cerebral aneurysms using "bioactive" or coated-coil technologies: a systematic review of the literature.

Authors:  P M White; J Raymond
Journal:  AJNR Am J Neuroradiol       Date:  2008-10-08       Impact factor: 3.825

3.  Interobserver agreement for the assessment of handicap in stroke patients.

Authors:  J C van Swieten; P J Koudstaal; M C Visser; H J Schouten; J van Gijn
Journal:  Stroke       Date:  1988-05       Impact factor: 7.914

4.  Hydrogel-coated coils versus bare platinum coils for the endovascular treatment of intracranial aneurysms (HELPS): a randomised controlled trial.

Authors:  Philip M White; Stephanie C Lewis; Anil Gholkar; Robin J Sellar; Hans Nahser; Christophe Cognard; Lynn Forrester; Joanna M Wardlaw
Journal:  Lancet       Date:  2011-05-14       Impact factor: 79.321

5.  Embolization of intracranial aneurysms with HydroSoft coils: results of the Korean multicenter study.

Authors:  J H Park; H-S Kang; M H Han; P Jeon; D-S Yoo; T H Lee
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-15       Impact factor: 3.825

6.  Endovascular treatment of unruptured aneurysms.

Authors:  D Roy; G Milot; J Raymond
Journal:  Stroke       Date:  2001-09       Impact factor: 7.914

7.  Long-term angiographic and histological results of a new hydrogel-containing filling coil in experimental rabbit aneurysms.

Authors:  M Killer; D Kallmes; R Jones; Y Ding; M Vestal; T Hauser; R Virmani; G Cruise
Journal:  Minim Invasive Neurosurg       Date:  2010-08-31

8.  Perioperative safety of Hydrosoft coils.

Authors:  Ben Waldau; Aquilla S Turk; Parham Yashar; Ahmad Khaldi; Raymond D Turner; M Imran Chaudry; Adnan H Siddiqui; Elad I Levy; Brian L Hoh; J Mocco
Journal:  J Neurointerv Surg       Date:  2011-09-13       Impact factor: 5.836

9.  Evaluation of the new HydroSoft coil in a canine model of bifurcation aneurysm. Laboratory investigation.

Authors:  Tomoyuki Tsumoto; Yasunari Niimi; Alejandro Berenstein
Journal:  J Neurosurg       Date:  2009-07       Impact factor: 5.115

10.  Mid-term outcome of intracranial aneurysms treated with HydroSoft coils compared to historical controls treated with bare platinum coils: a single-center experience.

Authors:  Jong Young Lee; Jeong Hwa Seo; Seung Jin Lee; Young Je Son; Young Dae Cho; Hyun-Seung Kang; Moon Hee Han
Journal:  Acta Neurochir (Wien)       Date:  2014-07-01       Impact factor: 2.216

View more
  4 in total

1.  GREAT-a randomized controlled trial comparing HydroSoft/HydroFrame and bare platinum coils for endovascular aneurysm treatment: procedural safety and core-lab-assessedangiographic results.

Authors:  Christian A Taschner; René Chapot; Vincent Costalat; Paolo Machi; Patrick Courthéoux; Xavier Barreau; Jérôme Berge; Laurent Pierot; Kryzsztof Kadziolka; Betty Jean; Raphaël Blanc; Alessandra Biondi; Hervé Brunel; Sophie Gallas; Ansgar Berlis; Denis Herbreteau; Joachim Berkefeld; Horst Urbach; Samer El Shikh; Jens Fiehler; Hubert Desal; Erika Graf; Alain Bonafé
Journal:  Neuroradiology       Date:  2016-04-30       Impact factor: 2.804

2.  Second-Generation Hydrogel Coils for the Endovascular Treatment of Intracranial Aneurysms: A Randomized Controlled Trial.

Authors:  Christian A Taschner; René Chapot; Vincent Costalat; Paolo Machi; Patrick Courthéoux; Xavier Barreau; Jérôme Berge; Laurent Pierot; Krzysztof Kadziolka; Betty Jean; Raphaël Blanc; Alessandra Biondi; Hervé Brunel; Sophie Gallas; Ansgar Berlis; Denis Herbreteau; Joachim Berkefeld; Horst Urbach; Samer Elsheikh; Jens Fiehler; Hubert Desal; Erika Graf; Alain Bonafé
Journal:  Stroke       Date:  2018-02-06       Impact factor: 7.914

3.  Hydrogel coils versus bare platinum coils for the endovascular treatment of intracranial aneurysms: a meta-analysis of randomized controlled trials.

Authors:  Tao Xue; Zhouqing Chen; Weiwei Lin; Jiayi Xu; Xuming Shen; Zhong Wang
Journal:  BMC Neurol       Date:  2018-10-05       Impact factor: 2.474

4.  Histological and Transmission Electron Microscopy Results after Embolization with HydroSoft/HydroFrame Coils in Experimental Swine Aneurysm.

Authors:  Seisuke Iseki; Yumiko Mitome-Mishima; Ikuko Ogino; Yasuo Suga; Kenji Yatomi; Senshu Nonaka; Nobukazu Miyamoto; Akihide Kondo; Munetaka Yamamoto; Hajime Arai; Hidenori Oishi
Journal:  Biomed Res Int       Date:  2019-12-05       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.