Quantifying the effect of off-focal radiation on the output of kilovoltage x-ray systems.

E S M Ali1, D W O Rogers.   

Abstract

In a typical x-ray tube, off-focal radiation is mainly generated by the backscattered electrons that reenter the anode outside the focal spot. In this study, BEAMnrc (an EGSnrc user-code) is modified to simulate off-focal radiation. The modified BEAMnrc code is used to study the characteristics of electrons that backscatter from the anode, and to quantify their effect on the output of typical x-ray systems. Results show that the first generation backscatter coefficient is approximately 50% for tungsten anodes at diagnostic energies, and approximately 38% for molybdenum anodes at mammography energies. Second and higher generations of backscatter have a relatively minor contribution. At the patient plane, our simulation results are in excellent agreement with experimental measurements in the literature for the spectral shape of both the primary and the off-focal components, and also for the integral off-focal-to-primary ratio. The spectrum of the off-focal component at the patient plane is softer than the primary, which causes a slight softening in the overall spectrum. For typical x-ray systems, the off-focal component increases patient exposure (for a given number of incident primary electrons) by up to 11% and reduces the half-value layer and the effective energy of the average spectrum by up to 7% and 3%, respectively. The larger effects are for grounded cathode tubes, smaller interelectrode distance, higher tube voltage, lighter filtration, and less collimation. Simulation time increases by approximately 30% when the off-focal radiation is included, but the overall simulation time remains of the order of a few minutes. This study concludes that the off-focal radiation can have a non-negligible effect on the output parameters of x-ray systems and that it should be included in x-ray tube simulations for more realistic modeling of these systems.

Entities:  

Mesh:

Year:  2008        PMID: 18841868     DOI: 10.1118/1.2966348

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Nondestructive measurement of the grid ratio using a single image.

Authors:  A S Pasciak; A Kyle Jones
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

2.  Estimating scatter from sparsely measured primary signal.

Authors:  Gongting Wu; Christina R Inscoe; Jabari Calliste; Jing Shan; Yueh Z Lee; Otto Zhou; Jianping Lu
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-29

3.  Local filtration based scatter correction for cone-beam CT using primary modulation.

Authors:  Lei Zhu
Journal:  Med Phys       Date:  2016-11       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.