Nondestructive measurement of the grid ratio using a single image.

A S Pasciak1, A Kyle Jones.   

Abstract

The antiscatter grid is an essential part of modern radiographic systems. Since the introduction of the antiscatter grid, however, there have been few methods proposed for acceptance testing and verification of manufacturer-supplied grid specifications. The grid ratio (r) is an important parameter describing the antiscatter grid because it affects many other grid quality metrics, such as the contrast improvement ratio (K), primary transmission (Tp), and scatter transmission (Ts). Also, the grid ratio in large part determines the primary clinical use of the grid. To this end, the authors present a technique for the nondestructive measurement of the grid ratio of antiscatter grids. They derived an equation that can be used to calculate the grid ratio from a single off-focus flat field image by exploiting the relationship between grid cutoff and off-focus distance. The calculation can be performed by hand or with included analysis software. They calculated the grid ratios of several different grids throughout the institution, and afterward they destructively measured the grid ratio of a nominal r8 grid previously evaluated with the method. They also studied the sensitivity of the method to technical factors and choice of parameters. With one exception, the results for the grids found in the institution were in agreement with the manufacturer's specifications and international standards. The nondestructive evaluation of the r8 grid indicated a ratio of 7.3, while the destructive measurement indicated a ratio of 7.53 +/- 0.28. Repeated evaluations of the same grid yielded consistent results. The technique provides the medical physicist with a new tool for quantitative evaluation of the grid ratio, an important grid performance criterion. The method is robust and repeatable when appropriate choices of technical factors and other parameters are made.

Mesh:

Year:  2009        PMID: 19928103      PMCID: PMC4034420          DOI: 10.1118/1.3191245

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Quality and choice of Potter Bucky grids. I. A new method for the unambiguous determination of the quality of a grid.

Authors:  J G BONENKAMP; W H BOLDINGH
Journal:  Acta radiol       Date:  1959-06       Impact factor: 1.990

2.  Quality and choice of Potter Bucky grids. II. Application of the criterion of quality to various types of grids.

Authors:  J G BOENENKAMP; W H BOLDINGH
Journal:  Acta radiol       Date:  1959-08       Impact factor: 1.990

3.  Quality and choice of Potter Bucky grids. III. The choice of Bucky grid.

Authors:  J G BONENKAMP; W H GOLDINGH
Journal:  Acta radiol       Date:  1959-09       Impact factor: 1.990

4.  [Graphic determination of primary radiation losses due to incorrect centration & movement of antidiffusing screens].

Authors:  W H BOLDINGH
Journal:  Fortschr Geb Rontgenstr Nuklearmed       Date:  1958-08

5.  The spectrum and intensity of extra-focal (off-focus) radiation.

Authors:  R Birch
Journal:  Br J Radiol       Date:  1976-11       Impact factor: 3.039

6.  Quantifying the effect of off-focal radiation on the output of kilovoltage x-ray systems.

Authors:  E S M Ali; D W O Rogers
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

7.  Characteristics of extrafocal radiation and its potential significance in pediatric radiology.

Authors:  S R Thomas; J E Freshcorn; K B Krugh; G C Henry; J G Kereiakes; R A Kaufman
Journal:  Radiology       Date:  1983-03       Impact factor: 11.105

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.