HYPOTHESIS: To study variations in human cochlea anatomy with potential implications for cochlear implantation surgery.
BACKGROUND: A comprehension of the anatomic variations of the human cochlea is essential for understanding the degree of surgical trauma induced by inserting various electrode arrays in cochlear implantation surgery. Variations in anatomy may also limit the potential for performing hearing preservation.
METHODS: We studied 73 archival, nonselected, adult, corrosion casts of human inner ears. Anatomic reference points were constructed from photographic reproductions taken at different angles, and various dimensions were assessed using planimetry. Anatomic variants with particular clinical/surgical interests were pinpointed.
RESULTS: Results showed that the human cochlea is individually shaped, varying greatly in dimensions ("fingerprint"). The outer cochlear wall length ranged from 38.6 to 45.6 mm with a mean length of 42.0 mm. The first turn represented 53% of the total length and ranged from 20.3 to 24.3 mm. The number of quadrants varied from slightly more than 8 to 12. The facial nerve canal ran in close proximity to the upper first turn explaining facial nerve excitement during stimulation of electrodes in this region in some instances. The internal diameter (height) of the cochlear tube in the first turn varied broadly (1.6-2.6 mm), occasionally with limited space for conventional implants.
CONCLUSION: The human cochlea exhibits extensive anatomic variations. These variations will influence the location of cochlear implant arrays and affect the potential of hearing preservation surgery. Our results may explain the surgeon's difficulties sometimes to insert electrode arrays even in so-called "normal" cochleae.

Entities:  

Mesh:

Year:  2009        PMID: 18833017     DOI: 10.1097/MAO.0b013e31818a08e8

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  65 in total

1.  Variability of the mental representation of the cochlear anatomy during cochlear implantation.

Authors:  Renato Torres; Guillaume Kazmitcheff; Daniele Bernardeschi; Daniele De Seta; Jean Loup Bensimon; Evelyne Ferrary; Olivier Sterkers; Yann Nguyen
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-09-01       Impact factor: 2.503

2.  Evaluation of a high-resolution patient-specific model of the electrically stimulated cochlea.

Authors:  Ahmet Cakir; Robert T Dwyer; Jack H Noble
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-14

3.  Automatic Cochlear Duct Length Estimation for Selection of Cochlear Implant Electrode Arrays.

Authors:  Alejandro Rivas; Ahmet Cakir; Jacob B Hunter; Robert F Labadie; M Geraldine Zuniga; George B Wanna; Benoit M Dawant; Jack H Noble
Journal:  Otol Neurotol       Date:  2017-03       Impact factor: 2.311

Review 4.  Soft cochlear implantation: rationale for the surgical approach.

Authors:  David R Friedland; Christina Runge-Samuelson
Journal:  Trends Amplif       Date:  2009-06

5.  Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes.

Authors:  George B Wanna; Jack H Noble; Matthew L Carlson; René H Gifford; Mary S Dietrich; David S Haynes; Benoit M Dawant; Robert F Labadie
Journal:  Laryngoscope       Date:  2014-05-30       Impact factor: 3.325

6.  Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT).

Authors:  C Güldner; S Wiegand; R Weiss; S Bien; A Sesterhenn; A Teymoortash; I Diogo
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-07-30       Impact factor: 2.503

7.  Human Inner-ear Malformation Types Captured in 3D.

Authors:  Anandhan Dhanasingh; Aarno Dietz; Claude Jolly; Peter Roland
Journal:  J Int Adv Otol       Date:  2019-04       Impact factor: 1.017

8.  Evaluation of Rigid Cochlear Models for Measuring Cochlear Implant Electrode Position.

Authors:  Ahmet Cakir; Robert F Labadie; M Geraldine Zuniga; Benoit M Dawant; Jack H Noble
Journal:  Otol Neurotol       Date:  2016-12       Impact factor: 2.311

9.  Ganglion cell and 'dendrite' populations in electric acoustic stimulation ears.

Authors:  Helge Rask-Andersen; Wei Liu; Fred Linthicum
Journal:  Adv Otorhinolaryngol       Date:  2009-11-25

10.  Effect of Scala Tympani Height on Insertion Depth of Straight Cochlear Implant Electrodes.

Authors:  William G Morrel; Jourdan T Holder; Benoit M Dawant; Jack H Noble; Robert F Labadie
Journal:  Otolaryngol Head Neck Surg       Date:  2020-02-25       Impact factor: 3.497

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.