Literature DB >> 18832976

Regional variation in the refractive-index of the bovine and human cornea.

Balamurali Vasudevan1, Trefford L Simpson, Jacob G Sivak.   

Abstract

PURPOSE: Given the refractive importance of the human cornea, surprisingly little attention has been directed to the study of local variation in corneal refractive-index. This in vitro and in vivo study measures the refractive-index of different portions of the bovine and human cornea.
METHODS: Fifty fresh bovine corneas (obtained from an abattoir) and 10 human subjects were used for the study. The refractive-index of the central, nasal, and temporal corneal epithelium was measured with a bench-top Abbe refractometer in the case of bovine corneas and with a hand-held refractometer with humans.
RESULTS: The mean (+/-standard deviation) refractive-indices of the central, nasal, and temporal bovine corneal epithelium were 1.3760 (+/-0.003), 1.3757 (+/-0.002), and 1.3746 (+/-0.002), respectively. Refractive-indices of the anterior and posterior bovine corneal stroma were 1.3731 (+/-0.002) and 1.3708 (+/-0.004), respectively. The mean (+/-standard deviation) refractive-index in the central, nasal, and temporal periphery of the human cornea epithelium were 1.3970 (+/-0.001), 1.3946 (+/-0.001), and 1.3940 (+/-0.001), respectively.
CONCLUSION: There are small local differences in the refractive-index of the bovine and human corneal epithelium and the refractive-index of the epithelium is higher than that of the anterior and posterior stroma of the bovine cornea.

Entities:  

Mesh:

Year:  2008        PMID: 18832976     DOI: 10.1097/OPX.0b013e3181886fa5

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  7 in total

1.  Brillouin optical microscopy for corneal biomechanics.

Authors:  Giuliano Scarcelli; Roberto Pineda; Seok Hyun Yun
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-01-20       Impact factor: 4.799

2.  Vertical and horizontal corneal epithelial thickness profiles determined by ultrahigh resolution optical coherence tomography.

Authors:  Chixin Du; Jianhua Wang; Lele Cui; Meixiao Shen; Yimin Yuan
Journal:  Cornea       Date:  2012-09       Impact factor: 2.651

3.  Cornea characterization using a combined multiphoton microscopy and optical coherence tomography system.

Authors:  Tom Lai; Shuo Tang
Journal:  Biomed Opt Express       Date:  2014-04-14       Impact factor: 3.732

4.  Optical side-effects of fs-laser treatment in refractive surgery investigated by means of a model eye.

Authors:  Roland Ackermann; Robert Kammel; Marina Merker; Andreas Kamm; Andreas Tünnermann; Stefan Nolte
Journal:  Biomed Opt Express       Date:  2013-01-10       Impact factor: 3.732

5.  Relationship between vessel diameter and depth measurements within the limbus using ultra-high resolution optical coherence tomography.

Authors:  Emmanuel Alabi; Natalie Hutchings; Kostadinka Bizheva; Trefford Simpson
Journal:  J Optom       Date:  2017-06-17

6.  New algorithm for corneal densitometry assessment based on anterior segment optical coherence tomography.

Authors:  Xiao Yu Wang; Jorge Peraza-Nieves; Tian Qiao Zhang; Anil Rahul Rachwani; Irene Blanco-Domínguez; Carlos Rocha de Lossada; Afredo Manuel Adán-Civiera
Journal:  Eye (Lond)       Date:  2021-08-02       Impact factor: 4.456

7.  Effect of Cataract Surgery on the Refractive Index of the Cornea Estimated by Optical Pachymetry.

Authors:  Larysa Tutchenko; Sudi Patel; Olha Horak; Volodymyr Sanin; Serhii Kosuba
Journal:  Cornea       Date:  2018-11       Impact factor: 2.651

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.