We report the clinical and radiological outcome at ten years of 104 primary total hip replacements (100 patients) using the Metasul metal-on-metal bearing. Of these, 52 had a cemented Stuehmer-Weber polyethylene acetabular component with a Metasul bearing and 52 had an uncemented Allofit acetabular component with a Metasul liner. A total of 15 patients (16 hips) died before their follow-up at ten years and three were lost to follow-up. The study group therefore comprised 82 patients (85 hips). The mean Oxford score at ten years was 20.7 (12 to 42). Six of 85 hips required revision surgery. One was performed because of infection, one for aseptic loosening of the acetabular component and four because of unexplained pain. Histological examination showed an aseptic lymphocytic vasculitis associated lesion-type tissue response in two of these. Continued follow-up is advocated in order to monitor the long-term performance of the Metasul bearing and tissue responses to metal debris.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18827235     DOI: 10.1302/0301-620X.90B10.20378

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  26 in total

1.  Cup loosening after cemented Metasul® total hip replacement: a retrieval analysis.

Authors:  Christophe Nich; Moussa Hamadouche
Journal:  Int Orthop       Date:  2010-06-11       Impact factor: 3.075

Review 2.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  Changes in serum chromium levels over 12 years after Metasul metal-on-metal total hip arthroplasty.

Authors:  Katsuhiko Maezawa; Masahiko Nozawa; Takahito Yuasa; Munehiko Sugimoto; Kazuo Kaneko
Journal:  J Orthop       Date:  2018-02-28

Review 4.  Revision arthroplasty: an update.

Authors:  D Williams; A Taylor; P McLardy-Smith
Journal:  Skeletal Radiol       Date:  2009-11       Impact factor: 2.199

5.  Cemented metal-on-metal total hip replacement with 28-mm head: prospective, long-term, clinical, radiological and metal ions data.

Authors:  Ibrahim A Malek; Sheethal Prasad Patange Subba Rao; Narendra Kumar Rath; U N Mallya
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-12-19

6.  A painful soft tissue mass secondary to impingement of a metal on polyethylene bearing total hip arthroplasty.

Authors:  Griffiths-Jones William; Williams Daniel
Journal:  BMJ Case Rep       Date:  2014-05-20

7.  Minimum ten-year results of a 28-mm metal-on-metal bearing in cementless total hip arthroplasty in patients fifty years of age and younger.

Authors:  Moritz M Innmann; Tobias Gotterbarm; Jan Philippe Kretzer; Christian Merle; Volker Ewerbeck; Stefan Weiss; Peter R Aldinger; Marcus R Streit
Journal:  Int Orthop       Date:  2013-12-20       Impact factor: 3.075

8.  [Complications of metal-on-metal tribological pairing].

Authors:  M Stiehler; F Zobel; F Hannemann; J Schmitt; J Lützner; S Kirschner; K-P Günther; A Hartmann
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

9.  Adverse Reactions to Metal on Metal Are Not Exclusive to Large Heads in Total Hip Arthroplasty.

Authors:  Adolph V Lombardi; Keith R Berend; Joanne B Adams; Keri L Satterwhite
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

10.  Risk of impingement and third-body abrasion with 28-mm metal-on-metal bearings.

Authors:  Ian C Clarke; Jean-Yves Lazennec; Adrien Brusson; Christina Savisaar; John G Bowsher; Michelle Burgett; Thomas K Donaldson
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.