Literature DB >> 18826158

Development and optimization of T2 weighted methods with reduced RF power deposition (Hyperecho-TSE) for magnetic resonance imaging.

Matthias Weigel1, Juergen Hennig.   

Abstract

Turbo or fast spin echo (TSE/FSE) techniques with variable flip angles have the potential to overcome specific absorption rate (SAR) limitations. Such Hyperecho-TSE sequences allow for high resolution imaging with full signal-to-noise ratio (SNR) compared to standard TSE methods. Initially, a short overview of the two basic hyperecho schemes is given. Subsequently, the manuscript focuses on the flexible hyperecho approach "TRAPS" (smooth transitions between pseudo steady states). Basic criteria for flip angle ramp selection are illustrated. Further prerequisites to establish hyperecho methods in a clinical environment such as an automatic ramp selection are discussed. A summary of the introduced framework for contrast characterization and adaptation for conventional and Hyperecho-TSE sequences is presented Finally, recent developments in hyperecho imaging are provided

Mesh:

Substances:

Year:  2008        PMID: 18826158     DOI: 10.1016/j.zemedi.2008.01.008

Source DB:  PubMed          Journal:  Z Med Phys        ISSN: 0939-3889            Impact factor:   4.820


  4 in total

1.  Possibilities and limitations for high resolution small animal MRI on a clinical whole-body 3T scanner.

Authors:  Karl-Heinz Herrmann; Silvio Schmidt; Alexandra Kretz; Ronny Haenold; Ines Krumbein; Martin Metzler; Christian Gaser; Otto W Witte; Jürgen R Reichenbach
Journal:  MAGMA       Date:  2011-10-22       Impact factor: 2.310

2.  Radiofrequency heating and magnetically induced displacement of dental magnetic attachments during 3.0 T MRI.

Authors:  K Miyata; M Hasegawa; Y Abe; T Tabuchi; T Namiki; T Ishigami
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

3.  T2 quantification in brain using 3D fast spin-echo imaging with long echo trains.

Authors:  Jeff Snyder; Kelly C McPhee; Alan H Wilman
Journal:  Magn Reson Med       Date:  2021-12-11       Impact factor: 3.737

4.  Imaging multiple sclerosis pathology at 160 μm isotropic resolution by human whole-brain ex vivo magnetic resonance imaging at 3 T.

Authors:  Matthias Weigel; Peter Dechent; Riccardo Galbusera; Erik Bahn; Govind Nair; Po-Jui Lu; Ludwig Kappos; Wolfgang Brück; Christine Stadelmann; Cristina Granziera
Journal:  Sci Rep       Date:  2021-07-29       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.