Literature DB >> 18825469

A one-wire method for anatomic reduction of tibial fractures with Ilizarov frame.

Giovanni Lovisetti1, Lorenzo Bettella.   

Abstract

UNLABELLED: Traditional external fixator techniques do not always correct minor residual malalignment. We asked whether using a one-wire method that corrects minor malalignment with an olive traction wire placed in the plane of the deformity allowed (1) uniform healing, (2) proper alignment, and (3) adequate reduction of fracture gaps. We retrospectively evaluated 72 patients in whom we used closed tibial fracture reduction using a circular external frame. We identified the plane of the residual deformity after alignment on a traction table using a C-arm. In this plane, the final correction was performed with traction through an olive wire. Satisfactory alignment (less than 3 degrees deviation from normal) was obtained in 68 of the 72 patients (94%), and satisfactory reduction (gaps less than 2 mm) attained in 51 (71%). In no case was the fracture site opened surgically. Four patients underwent additional alignment correction with conical washers outside the operating room but no other efforts were needed to obtain further reduction after the initial surgery. Fractures healed in an average of 20 weeks. We observed no major infections. The Ilizarov frame has been a valuable tool to achieve alignment and anatomic or near anatomic reduction of closed tibial fractures. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2008        PMID: 18825469      PMCID: PMC2628226          DOI: 10.1007/s11999-008-0517-8

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  10 in total

1.  Fracture reduction and deformity correction with the hexapod Ilizarov fixator.

Authors:  K Seide; D Wolter; H R Kortmann
Journal:  Clin Orthop Relat Res       Date:  1999-06       Impact factor: 4.176

2.  Mechanical considerations in using tensioned wires in a transosseous external fixation system.

Authors:  J Aronson; J H Harp
Journal:  Clin Orthop Relat Res       Date:  1992-07       Impact factor: 4.176

3.  The Rancho mounting technique for the Ilizarov method. A preliminary report.

Authors:  S A Green; N L Harris; D M Wall; J Ishkanian; H Marinow
Journal:  Clin Orthop Relat Res       Date:  1992-07       Impact factor: 4.176

4.  Factors affecting fracture healing after intramedullary nailing of the tibial diaphysis for closed and grade I open fractures.

Authors:  G I Drosos; M Bishay; I A Karnezis; A K Alegakis
Journal:  J Bone Joint Surg Br       Date:  2006-02

5.  Management of unstable open and closed tibial fractures using the Ilizarov method.

Authors:  H L Tucker; J C Kendra; T E Kinnebrew
Journal:  Clin Orthop Relat Res       Date:  1992-07       Impact factor: 4.176

6.  The care of pin sites with external fixation.

Authors:  R Davies; N Holt; S Nayagam
Journal:  J Bone Joint Surg Br       Date:  2005-05

7.  [Correction of deformities with conventional and hexapod frames--comparison of methods].

Authors:  R Rödl; B Leidinger; A Böhm; W Winkelmann
Journal:  Z Orthop Ihre Grenzgeb       Date:  2003 Jan-Feb

8.  Spiral and oblique fractures of distal one-third of tibia-fibula: treatment results with circular external fixator.

Authors:  Bahtiyar Demiralp; Ali Sabri Atesalp; Murat Bozkurt; Dogan Bek; Ersin Tasatan; Cagatay Ozturk; Mustafa Basbozkurt
Journal:  Ann Acad Med Singapore       Date:  2007-04       Impact factor: 2.473

9.  Spiral fractures of the shaft of the tibia. Initial displacement and stability of reduction.

Authors:  O M Böstman
Journal:  J Bone Joint Surg Br       Date:  1986-05

10.  Temporary distraction and compression of a diaphyseal osteotomy accelerates bone healing.

Authors:  Lutz Claes; Peter Augat; Sandra Schorlemmer; Christian Konrads; Anita Ignatius; Christian Ehrnthaller
Journal:  J Orthop Res       Date:  2008-06       Impact factor: 3.494

  10 in total
  1 in total

1.  The use of circular external fixators in the management of lower limb trauma in Dublin: a single surgeon's 20-year experience.

Authors:  B J O'Neill; C M Fox; A P Molloy; S O'hEireamhoin; D P Moore
Journal:  Ir J Med Sci       Date:  2014-12-28       Impact factor: 1.568

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.