Literature DB >> 1611749

Mechanical considerations in using tensioned wires in a transosseous external fixation system.

J Aronson1, J H Harp.   

Abstract

Factors that affect wire tension were examined using external mechanical testing units as well as in-line load cells. The circular external fixator with wires supported at each end exhibits a self-stiffening effect such that wire stiffness increases with wire deflection. Mechanical slippage between wire and fixation bolt is the primary reason for loss of wire tension. Slippage can be avoided by adequate torque on the fixation nut (20 N.m). Guidelines are presented for proper and safe tensioning techniques to achieve clinically indicated tensions without risk of breakage.

Entities:  

Mesh:

Year:  1992        PMID: 1611749

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  Analytical modelling of Kirschner wires in Ilizarov circular external fixator as pretensioned slender beams.

Authors:  A R Zamani; S O Oyadiji
Journal:  J R Soc Interface       Date:  2009-03-06       Impact factor: 4.118

2.  Towards a solution of the wires' slippage problem of the Ilizarov external fixator.

Authors:  C Bairaktari; G Athanassiou; E Panagiotopoulos; D Deligianni
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-08-20

Review 3.  External fixators: looking beyond the hardware maze.

Authors:  Kimia Khalatbari Kani; Jack A Porrino; Felix S Chew
Journal:  Skeletal Radiol       Date:  2019-09-12       Impact factor: 2.199

4.  A one-wire method for anatomic reduction of tibial fractures with Ilizarov frame.

Authors:  Giovanni Lovisetti; Lorenzo Bettella
Journal:  Clin Orthop Relat Res       Date:  2008-09-27       Impact factor: 4.176

5.  Biomechanical Analysis of the Behaviour at the Metaphyseal-Diaphyseal Junction of Complex Tibial Plateau Fractures Using Two Circular Fixator Configurations.

Authors:  Gracielle S Cardoso; Renato Amorim; Francisco M Penha; Françoá J Horn; Carlos Rm Roesler; Jefferson Lb Marques
Journal:  Strategies Trauma Limb Reconstr       Date:  2020 Sep-Dec

6.  Direct and indirect loading of the Ilizarov external fixator: the effect on the interfragmentary movements and compressive loads.

Authors:  Jan Gessmann; Hinnerk Baecker; Birger Jettkant; Gert Muhr; Dominik Seybold
Journal:  Strategies Trauma Limb Reconstr       Date:  2011-02-11

7.  The use of twin-ring Ilizarov external fixator constructs: application and biomechanical proof-of principle with possible clinical indications.

Authors:  Theodoros B Grivas; Evangelos A Magnissalis
Journal:  J Orthop Surg Res       Date:  2011-08-11       Impact factor: 2.359

8.  The influence of a weight-bearing platform on the mechanical behavior of two Ilizarov ring fixators: tensioned wires vs. half-pins.

Authors:  Jan Gessmann; Mustafa Citak; Birger Jettkant; Thomas A Schildhauer; Dominik Seybold
Journal:  J Orthop Surg Res       Date:  2011-12-12       Impact factor: 2.359

9.  Influence of Different Connecting Rod Configurations on the Stability of the Ilizarov/TSF Frame: A Biomechanical Study.

Authors:  Gerhard Thiart; Christopher Herbert; Sudesh Sivarasu; Saadiq Gasant; Maritz Laubscher
Journal:  Strategies Trauma Limb Reconstr       Date:  2020 Jan-Apr
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.