Literature DB >> 1611729

The Rancho mounting technique for the Ilizarov method. A preliminary report.

S A Green1, N L Harris, D M Wall, J Ishkanian, H Marinow.   

Abstract

To improve implant tolerance and muscle function associated with circular external fixation, the authors substituted divergent titanium pins for the tensioned steel wires used to mount the Ilizarov apparatus on a limb. The first ten patients treated with half-pins were compared to the last ten patients managed with tensioned wires. While the conditions were not exactly comparable, the half-pin group showed improvement over the wire group in categories including time in fixation, implant-site sepsis, range of joint motion, pain medication requirements, and ambulatory capacity. Half-pin mountings require special techniques for a successful application.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1611729

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  Reconstruction of Large Diaphyseal Defects of the Femur and the Tibia with Autologous Bone.

Authors:  Charles E Dumont; Ulrich G Exner
Journal:  Eur J Trauma Emerg Surg       Date:  2009-01-19       Impact factor: 3.693

2.  Circular external fixation frames with divergent half pins: a pilot biomechanical study.

Authors:  Christopher Lenarz; Gary Bledsoe; J Tracy Watson
Journal:  Clin Orthop Relat Res       Date:  2008-09-18       Impact factor: 4.176

3.  A one-wire method for anatomic reduction of tibial fractures with Ilizarov frame.

Authors:  Giovanni Lovisetti; Lorenzo Bettella
Journal:  Clin Orthop Relat Res       Date:  2008-09-27       Impact factor: 4.176

4.  Ilizarov methodology for infected non union of the Tibia: Classic circular transfixion wire assembly vs. hybrid assembly.

Authors:  Ranjit Kr Baruah
Journal:  Indian J Orthop       Date:  2007-07       Impact factor: 1.251

5.  Descriptive report of antebrachial growth deformity correction in 17 dogs from 1999 to 2007, using hybrid linear-circular external fixator constructs.

Authors:  Colin W Sereda; Daniel D Lewis; Robert M Radasch; Charles W Bruce; Kristin A Kirkby
Journal:  Can Vet J       Date:  2009-07       Impact factor: 1.008

6.  The influence of a weight-bearing platform on the mechanical behavior of two Ilizarov ring fixators: tensioned wires vs. half-pins.

Authors:  Jan Gessmann; Mustafa Citak; Birger Jettkant; Thomas A Schildhauer; Dominik Seybold
Journal:  J Orthop Surg Res       Date:  2011-12-12       Impact factor: 2.359

7.  Stability at the half pin-frame interface on external fixation constructs.

Authors:  Alexios Dimitrios Iliadis; Parag Kumar Jaiswal; Jay Meswania; Gordon Blunn; David Goodier; Peter Calder
Journal:  Strategies Trauma Limb Reconstr       Date:  2016-10-13

8.  Treatment of infected non-unions with segmental defects with a rail fixation system.

Authors:  Srikanth Mudiganty; Arup Kumar Daolagupu; Arun Kumar Sipani; Satyendra Kumar Das; Arijit Dhar; Parag Jyoti Gogoi
Journal:  Strategies Trauma Limb Reconstr       Date:  2017-02-24

9.  Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis.

Authors:  Ashraf A Khanfour; Mohamed M El-Sayed
Journal:  Strategies Trauma Limb Reconstr       Date:  2014-07-29
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.