Literature DB >> 18824785

Shading correction algorithm for improvement of cone-beam CT images in radiotherapy.

T E Marchant1, C J Moore, C G Rowbottom, R I MacKay, P C Williams.   

Abstract

Cone-beam CT (CBCT) images have recently become an established modality for treatment verification in radiotherapy. However, identification of soft-tissue structures and the calculation of dose distributions based on CBCT images is often obstructed by image artefacts and poor consistency of density calibration. A robust method for voxel-by-voxel enhancement of CBCT images using a priori knowledge from the planning CT scan has been developed and implemented. CBCT scans were enhanced using a low spatial frequency grey scale shading function generated with the aid of a planning CT scan from the same patient. This circumvents the need for exact correspondence between CBCT and CT and the process is robust to the appearance of unshared features such as gas pockets. Enhancement was validated using patient CBCT images. CT numbers in regions of fat and muscle tissue in the processed CBCT were both within 1% of the values in the planning CT, as opposed to 10-20% different for the original CBCT. Visual assessment of processed CBCT images showed improvement in soft-tissue visibility, although some cases of artefact introduction were observed.

Entities:  

Mesh:

Year:  2008        PMID: 18824785     DOI: 10.1088/0031-9155/53/20/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  20 in total

1.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Joint CT/CBCT deformable registration and CBCT enhancement for cancer radiotherapy.

Authors:  Yifei Lou; Tianye Niu; Xun Jia; Patricio A Vela; Lei Zhu; Allen R Tannenbaum
Journal:  Med Image Anal       Date:  2013-02-04       Impact factor: 8.545

3.  Dosimetric and volumetric effects in clinical target volume and organs at risk during postprostatectomy radiotherapy.

Authors:  Ahmed Gawish; Ahmed Ali Chughtai; Michael J Eble
Journal:  Strahlenther Onkol       Date:  2018-10-17       Impact factor: 3.621

4.  An evaluation of techniques for dose calculation on cone beam computed tomography.

Authors:  Valentina Giacometti; Raymond B King; Christina E Agnew; Denise M Irvine; Suneil Jain; Alan R Hounsell; Conor K McGarry
Journal:  Br J Radiol       Date:  2019-02-26       Impact factor: 3.039

5.  Dosimetric study on learning-based cone-beam CT correction in adaptive radiation therapy.

Authors:  Tonghe Wang; Yang Lei; Nivedh Manohar; Sibo Tian; Ashesh B Jani; Hui-Kuo Shu; Kristin Higgins; Anees Dhabaan; Pretesh Patel; Xiangyang Tang; Tian Liu; Walter J Curran; Xiaofeng Yang
Journal:  Med Dosim       Date:  2019-04-01       Impact factor: 1.482

6.  Clinical evaluation of soft tissue organ boundary visualization on cone-beam computed tomographic imaging.

Authors:  Elisabeth Weiss; Jian Wu; William Sleeman; Joshua Bryant; Priya Mitra; Michael Myers; Tatjana Ivanova; Nitai Mukhopadhyay; Viswanathan Ramakrishnan; Martin Murphy; Jeffrey Williamson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-09       Impact factor: 7.038

7.  Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

Authors:  Alexander Maslowski; Adam Wang; Mingshan Sun; Todd Wareing; Ian Davis; Josh Star-Lack
Journal:  Med Phys       Date:  2018-04-06       Impact factor: 4.071

8.  Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: first patient studies.

Authors:  Tianye Niu; Ahmad Al-Basheer; Lei Zhu
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

9.  Cone Beam Computed Tomography Image Quality Improvement Using a Deep Convolutional Neural Network.

Authors:  Satoshi Kida; Takahiro Nakamoto; Masahiro Nakano; Kanabu Nawa; Akihiro Haga; Jun'ichi Kotoku; Hideomi Yamashita; Keiichi Nakagawa
Journal:  Cureus       Date:  2018-04-29

10.  The effect of on-line position correction on the dose distribution in focal radiotherapy for bladder cancer.

Authors:  Dominique C van Rooijen; Jeroen B van de Kamer; René Pool; Maarten C C M Hulshof; Caro C E Koning; Arjan Bel
Journal:  Radiat Oncol       Date:  2009-09-24       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.