Literature DB >> 18812757

Contact lens-induced corneal peripheral swelling differences with extended wear.

Raul Martin1, Victoria de Juan, Guadalupe Rodriguez, Soraya Fonseca, Sofia Martin.   

Abstract

PURPOSE: To compare central and peripheral corneal swelling with high-Dk (lotrafilcon A) and low-Dk (etafilcon A) contact lenses (CLs) during extended wear (EW).
METHODS: Corneal thickness was measured in 5 corneal locations (central, superior, inferior, nasal, and temporal) with Orbscan II pachymetry 1 week before the wearing of CLs and after 1 week of EW. High-Dk (lotrafilcon A) and low-Dk (etafilcon A) soft CLs were randomly fitted for EW in the right and left eyes of 20 subjects with normal ocular health. Orbscan was also performed before CL removal after 3 and 7 days of EW.
RESULTS: Lotrafilcon A induced a lower percentage of corneal swelling in all 5 corneal locations than etafilcon A (P < 0.05, paired t test). Lotrafilcon A swelling percentages were as follows: central (1.67% +/- 2.22%), superior (2.04% +/- 3.25%), inferior (1.38% +/- 1.74%), nasal (1.50% +/- 2.00%), and temporal (1.27% +/- 1.47%). Etafilcon A swelling percentages were as follows: central (4.98% +/- 3.07%), superior (6.62% +/- 8.39%), inferior (5.24% +/- 5.54%), nasal (3.41% +/- 3.14%), and temporal (4.46% +/- 3.32%). Differences between the central and peripheral corneal swelling during EW of both types of lenses were not significant (P > 0.05, repeated-measures analysis of variance).
CONCLUSIONS: Central and peripheral corneal thicknesses increase more with etafilcon A than with lotrafilcon A during EW, as measured by Orbscan pachymetry.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18812757     DOI: 10.1097/ICO.0b013e318172fc2c

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  5 in total

1.  Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT.

Authors:  David Kuerten; Niklas Plange; Eva Charlotte Koch; Antonis Koutsonas; Peter Walter; Matthias Fuest
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-04-21       Impact factor: 3.117

2.  Measurements of central corneal thickness and endothelial parameters with three different non-contact specular microscopy devices.

Authors:  Ozgur Cakici; Remzi Karadag; Huseyin Bayramlar; Efe Koyun
Journal:  Int Ophthalmol       Date:  2016-05-24       Impact factor: 2.031

3.  Comparison of the precision of the Topcon SP-3000P specular microscope and an ultrasound pachymeter.

Authors:  Turki M Almubrad; Uchechukwu L Osuagwu; Ibrahim Alabbadi; Kelechi C Ogbuehi
Journal:  Clin Ophthalmol       Date:  2011-06-24

4.  Central and midperipheral corneal thickness measured with Scheimpflug imaging and optical coherence tomography.

Authors:  Jinhai Huang; Xixia Ding; Giacomo Savini; Zhengxuan Jiang; Chao Pan; Yanjun Hua; Fan Wu; Yifan Feng; Ye Yu; Qinmei Wang
Journal:  PLoS One       Date:  2014-05-22       Impact factor: 3.240

5.  Evaluation of corneal optical properties in subjects wearing hydrogel etafilcon A contact lenses and the effect of administering mannitol-enriched sodium hyaluronate ophthalmic solution.

Authors:  Marco Lombardo; Marianna Rosati; Marco Pileri; Domenico Schiano-Lomoriello; Sebastiano Serrao
Journal:  Clin Ophthalmol       Date:  2014-11-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.