MRI safety of Med-El C40/C40+ cochlear implants.

E S Hochmair1.   

Abstract

Cochlear implants are an accepted means for the treatment of profound bilateral deafness. Magnetic resonance imaging (MRI) is gaining more and more importance as a diagnostic tool. It is therefore very likely that cochlear implant wearers will, at some point in their life, become MRI candidates. This makes a discussion of MRI safety of cochlear implants a most timely subject. With the C40/C40+ system as an example, all the major and potentially troublesome interactions are discussed, as well as the conditions for the safe conduct of MR examinations with cochlear implant wearers. For the C40/C40+ systems, safe MR imaging is possible with 0.2 Tesla, 1.0 Tesla and 1.5 Tesla scanners.

Entities:  

Year:  2001        PMID: 18792092     DOI: 10.1179/cim.2001.2.2.98

Source DB:  PubMed          Journal:  Cochlear Implants Int        ISSN: 1467-0100


  5 in total

1.  Magnetic resonance imaging with the Digisonic SP Neurelec cochlear implant.

Authors:  C Vincent; I Ruzza; F M Vaneecloo; F Dubrulle
Journal:  Eur Arch Otorhinolaryngol       Date:  2008-02-23       Impact factor: 2.503

Review 2.  [Magnetic resonance imaging in patients with magnetic hearing implants: overview and procedural management].

Authors:  S Nospes; W Mann; A Keilmann
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

3.  Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study.

Authors:  Franca Wagner; Wilhelm Wimmer; Lars Leidolt; Mattheus Vischer; Stefan Weder; Roland Wiest; Georgios Mantokoudis; Marco D Caversaccio
Journal:  PLoS One       Date:  2015-07-22       Impact factor: 3.240

4.  Two-phase survey on the frequency of use and safety of MRI for hearing implant recipients.

Authors:  Paul van de Heyning; Griet Mertens; Vedat Topsakal; Ruben de Brito; Wilhelm Wimmer; Marco D Caversaccio; Stefan Dazert; Stefan Volkenstein; Mario Zernotti; Lorne S Parnes; Hinrich Staecker; Iain A Bruce; Gunesh Rajan; Marcus Atlas; Peter Friedland; Piotr H Skarzynski; Serafima Sugarova; Vladislav Kuzovkov; Abdulrahman Hagr; Robert Mlynski; Joachim Schmutzhard; Shin-Ichi Usami; Luis Lassaletta; Javier Gavilán; Benoit Godey; Christopher H Raine; Rudolf Hagen; Georg M Sprinzl; Kevin Brown; Wolf-Dieter Baumgartner; Eva Karltorp
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-03-31       Impact factor: 2.503

Review 5.  Safety of active auditory implants in magnetic resonance imaging.

Authors:  Guy Fierens; Nina Standaert; Ronald Peeters; Christ Glorieux; Nicolas Verhaert
Journal:  J Otol       Date:  2021-01-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.