Literature DB >> 18790125

Twenty years of interface development for capillary electrophoresis-electrospray ionization-mass spectrometry.

E Jane Maxwell1, David D Y Chen.   

Abstract

Capillary electrophoresis-electrospray ionization-mass spectrometry has the potential to become a preferred tool for the analysis of biological mixtures and other complex samples. The development of improved interfaces in the past twenty years has been critical in demonstrating the feasibility of this technique. However, a compromise still exists between interfaces that give optimal performance and those that are practical for commercial applications. The first section of this review focuses on the technological advances in CE-ESI-MS as they relate to the key interface features for both sheath-flow and sheathless systems: delivery of the sheath liquid, shaping of the emitter tip, formation of electrical contact, and practicality in terms of ease of use and lifetime. In the second section, we review the fundamental processes that affect interface performance. Because of the complex natures of both capillary electrophoresis and electrospray ionization, flow rate, arrangement of the electrical circuit, electrochemistry, tip geometry and location of electrical contact must all be carefully managed in the design of a successful interface.

Year:  2008        PMID: 18790125     DOI: 10.1016/j.aca.2008.06.034

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  33 in total

1.  Comparing and combining capillary electrophoresis electrospray ionization mass spectrometry and nano-liquid chromatography electrospray ionization mass spectrometry for the characterization of post-translationally modified histones.

Authors:  Bettina Sarg; Klaus Faserl; Leopold Kremser; Bernhard Halfinger; Roberto Sebastiano; Herbert H Lindner
Journal:  Mol Cell Proteomics       Date:  2013-05-29       Impact factor: 5.911

Review 2.  Recent advances in coupling capillary electrophoresis-based separation techniques to ESI and MALDI-MS.

Authors:  Xuefei Zhong; Zichuan Zhang; Shan Jiang; Lingjun Li
Journal:  Electrophoresis       Date:  2013-12-05       Impact factor: 3.535

3.  Ultrasensitive and fast bottom-up analysis of femtogram amounts of complex proteome digests.

Authors:  Liangliang Sun; Guijie Zhu; Yimeng Zhao; Xiaojing Yan; Si Mou; Norman J Dovichi
Journal:  Angew Chem Int Ed Engl       Date:  2013-10-31       Impact factor: 15.336

4.  Baking a mass-spectrometry data PIE with McMC and simulated annealing: predicting protein post-translational modifications from integrated top-down and bottom-up data.

Authors:  Stuart R Jefferys; Morgan C Giddings
Journal:  Bioinformatics       Date:  2011-03-15       Impact factor: 6.937

5.  Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection.

Authors:  Roza Wojcik; Yihan Li; Michael J Maccoss; Norman J Dovichi
Journal:  Talanta       Date:  2011-11-29       Impact factor: 6.057

6.  Third-generation electrokinetically pumped sheath-flow nanospray interface with improved stability and sensitivity for automated capillary zone electrophoresis-mass spectrometry analysis of complex proteome digests.

Authors:  Liangliang Sun; Guijie Zhu; Zhenbin Zhang; Si Mou; Norman J Dovichi
Journal:  J Proteome Res       Date:  2015-03-27       Impact factor: 4.466

7.  High speed capillary zone electrophoresis-mass spectrometry via an electrokinetically pumped sheath flow interface for rapid analysis of amino acids and a protein digest.

Authors:  Nicole M Schiavone; Scott A Sarver; Liangliang Sun; Roza Wojcik; Norman J Dovichi
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2015-04-09       Impact factor: 3.205

8.  Capillary electrophoresis with electrospray ionization mass spectrometric detection for single-cell metabolomics.

Authors:  Theodore Lapainis; Stanislav S Rubakhin; Jonathan V Sweedler
Journal:  Anal Chem       Date:  2009-07-15       Impact factor: 6.986

9.  CZE-ESI-MS/MS system for analysis of subnanogram amounts of tryptic digests of a cellular homogenate.

Authors:  Liangliang Sun; Guijie Zhu; Yihan Li; Roza Wojcik; Ping Yang; Norman J Dovichi
Journal:  Proteomics       Date:  2012-08-29       Impact factor: 3.984

10.  Capillary zone electrophoresis-multiple reaction monitoring from 100 pg of RAW 264.7 cell lysate digest.

Authors:  Liangliang Sun; Yihan Li; Matthew M Champion; Guijie Zhu; Roza Wojcik; Norman J Dovichi
Journal:  Analyst       Date:  2013-06-07       Impact factor: 4.616

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.