Literature DB >> 18784069

Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization.

M A Malik1, C H Maharaj, B H Harte, J G Laffey.   

Abstract

BACKGROUND: The purpose of this study was to evaluate the effectiveness of the Pentax AWS, Glidescope, and the Truview EVO2, in comparison with the Macintosh laryngoscope, when performing tracheal intubation in patients with neck immobilization using manual in-line axial cervical spine stabilization.
METHODS: One hundred and twenty consenting patients presenting for surgery requiring tracheal intubation were randomly assigned to undergo intubation using a Macintosh (n=30), Glidescope (n=30), Truview EVO2 (n=30), or AWS (n=30) laryngoscope. All patients were intubated by one of the three anaesthetists experienced in the use of each laryngoscope.
RESULTS: The Glidescope, AWS, and Truview EVO2 each reduced the intubation difficulty score (IDS), improved the Cormack and Lehane glottic view, and reduced the need for optimization manoeuvres, compared with the Macintosh. The mean IDS was significantly lower with the Glidescope and AWS compared with the Truview EVO2 device, and the IDS was lowest with the AWS. The duration of tracheal intubation attempts was significantly shorter with the Macintosh compared with the other devices. There were no differences in success rates between the devices tested. The AWS produced the least haemodynamic stimulation.
CONCLUSIONS: The Glidescope and AWS laryngoscopes required more time but reduced intubation difficulty and improved glottic view over the Macintosh laryngoscope more than the Truview EVO2 laryngoscope when used in patients undergoing cervical spine immobilization.

Entities:  

Mesh:

Year:  2008        PMID: 18784069     DOI: 10.1093/bja/aen231

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  64 in total

Review 1.  [Indirect laryngoscopy : Alternatives to securing the airway].

Authors:  R R Noppens; C Werner; T Piepho
Journal:  Anaesthesist       Date:  2010-02       Impact factor: 1.041

2.  [Polytrauma following a truck accident : How to save lives by guideline-oriented emergency care].

Authors:  M Kippnich; Y Jelting; C Markus; M Kredel; T Wurmb; P Kranke
Journal:  Anaesthesist       Date:  2017-09-27       Impact factor: 1.041

3.  A comparison of video laryngoscopy to direct laryngoscopy for the emergency intubation of trauma patients.

Authors:  Maria Michailidou; Terence O'Keeffe; Jarrod M Mosier; Randall S Friese; Bellal Joseph; Peter Rhee; John C Sakles
Journal:  World J Surg       Date:  2015-03       Impact factor: 3.352

4.  A Comparison of the Effects of Different Types of Laryngoscope on the Cervical Motions: Randomized Clinical Trial.

Authors:  Alkin Çolak; Elif Çopuroğlu; Ali Yılmaz; Sevtap Hekimoğlu Şahin; Nesrin Turan
Journal:  Balkan Med J       Date:  2015-04-01       Impact factor: 2.021

5.  Clinical evaluation of C-MAC videolaryngoscope with or without use of stylet for endotracheal intubation in patients with cervical spine immobilization.

Authors:  Nidhi Gupta; Girija Prasad Rath; Hemanshu Prabhakar
Journal:  J Anesth       Date:  2013-03-11       Impact factor: 2.078

6.  Evaluation of Truview evo2 Laryngoscope In Anticipated Difficult Intubation - A Comparison To Macintosh Laryngoscope.

Authors:  Ishwar Singh; Abhijit Khaund; Abhishek Gupta
Journal:  Indian J Anaesth       Date:  2009-04

7.  A comparison of the GlideScope video laryngoscope to the C-MAC video laryngoscope for intubation in the emergency department.

Authors:  Jarrod Mosier; Stephen Chiu; Asad E Patanwala; John C Sakles
Journal:  Ann Emerg Med       Date:  2013-01-30       Impact factor: 5.721

8.  A comparison of the C-MAC video laryngoscope to the Macintosh direct laryngoscope for intubation in the emergency department.

Authors:  John C Sakles; Jarrod Mosier; Stephen Chiu; Mari Cosentino; Leah Kalin
Journal:  Ann Emerg Med       Date:  2012-05-05       Impact factor: 5.721

9.  Predictors of difficult videolaryngoscopy with GlideScope® or C-MAC® with D-blade: secondary analysis from a large comparative videolaryngoscopy trial.

Authors:  M F Aziz; E O Bayman; M M Van Tienderen; M M Todd; A M Brambrink
Journal:  Br J Anaesth       Date:  2016-07       Impact factor: 9.166

10.  Comparison of hemodynamic responses to endotracheal intubation with the GlideScope video laryngoscope and Macintosh laryngoscope in patients undergoing cardiovascular surgery.

Authors:  Gökhan İnangil; Kadir Hakan Cansız; Fuat Gürbüz; Ömer Bakal; Fatma Merih Gökben; Hüseyin Şen
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-07-03       Impact factor: 0.332

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.