Abstract

BACKGROUND: Scapholunate advanced collapse wrist deformity is a common pattern of degenerative arthrosis of the wrist. This study prospectively evaluated a series of patients who underwent four-corner fusion using a circular plate internal fixation technique.
METHODS: Patients with symptomatic stage II scapholunate advanced collapse wrist deformity were treated with scaphoid excision and four-corner fusion using the Spider Limited Wrist Fusion Plate (KMI, San Diego, Calif.). Patients were prospectively evaluated at 6 months and 1 year using a standard study protocol with radiographs, functional tests, and an outcomes questionnaire. Outcomes were compared with those of historical series from the literature.
RESULTS: Eleven patients were enrolled and 10 patients completed their 1-year follow-up. Grip strength, lateral pinch strength, and Jebsen-Taylor test scores at 1 year were not significantly different from preoperative values. Mean active range of motion was 87 degrees preoperatively and 74 degrees at 1-year follow-up (p = 0.19). The Michigan Hand Outcomes Questionnaire showed no significant improvement in function, activities of daily living, work, pain, or patient satisfaction. The mean pain scores decreased from 54 preoperatively to 42 1-year postoperatively (p = 0.30), indicating persistent wrist discomfort. Three patients had broken screws: one was asymptomatic, one required 3 months of strict wrist immobilization, and one was reoperated for symptomatic nonunion.
CONCLUSIONS: Four-corner fusion using the first-generation Spider plate technique has the advantage of earlier mobility and more patient comfort from absence of protruding Kirschner wires; however, patients continued to have disabling pain, functional limitations, work impairment, and low satisfaction scores postoperatively. Although limited by a small patient sample, this series presents outcomes data that may be useful in counseling patients who are contemplating four-corner fusion using this internal fixation device. Further investigation is necessary to evaluate the biomechanical properties of the Spider plate. The data suggest that better implants should be designed to avoid implant failure, which occurred in three of the 11 patients in this series.

Entities:  

Mesh:

Year:  2006        PMID: 16874215     DOI: 10.1097/01.prs.0000227737.90007.5d

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  14 in total

1.  Proximal migration of hardware in patients undergoing midcarpal fusion with headless compression screws.

Authors:  Grant D Shifflett; Edward A Athanasian; Steve K Lee; Andrew J Weiland; Scott W Wolfe
Journal:  J Wrist Surg       Date:  2014-11

2.  Reliability of the 8 Week Time Point for Single Assessment of Midcarpal Fusion by CT Scan.

Authors:  Mark Henry
Journal:  J Hand Microsurg       Date:  2011-02-16

3.  Clinical research in hand surgery.

Authors:  Kevin C Chung
Journal:  J Hand Surg Am       Date:  2010-01       Impact factor: 2.230

4.  High fusion rates with circular plate fixation for four-corner arthrodesis of the wrist.

Authors:  Ben Bedford; S Steven Yang
Journal:  Clin Orthop Relat Res       Date:  2010-01       Impact factor: 4.176

5.  Internal headless compression screw method for 4-corner fusion.

Authors:  Mark Henry
Journal:  J Hand Microsurg       Date:  2009-07-10

6.  Scapholunate advanced collapse (SLAC) and scaphoid nonunion advanced collapse (SNAC) wrist arthritis.

Authors:  Chirag M Shah; Peter J Stern
Journal:  Curr Rev Musculoskelet Med       Date:  2013-03

7.  Effectiveness of four-corner arthrodesis with use of a locked dorsal circular plate.

Authors:  Matthias Luegmair; Patrick Houvet
Journal:  Clin Orthop Relat Res       Date:  2012-03-20       Impact factor: 4.176

8.  Development of a brief, 12-item version of the Michigan Hand Questionnaire.

Authors:  Jennifer F Waljee; H Myra Kim; Patricia B Burns; Kevin C Chung
Journal:  Plast Reconstr Surg       Date:  2011-07       Impact factor: 4.730

9.  Non-union scaphoid: Four-corner fusion of the wrist.

Authors:  Ravi K Gupta; Dalvir S Chauhan; Harmeet Singh
Journal:  Indian J Orthop       Date:  2010-04       Impact factor: 1.251

10.  Scaphoid excision and limited wrist fusion: a comparison of K-wire and circular plate fixation.

Authors:  Jeffrey A Rodgers; Gary Holt; Edward P Finnerty; Blake Miller
Journal:  Hand (N Y)       Date:  2008-04-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.