Literature DB >> 18758001

Monte Carlo simulation of RapidArc radiotherapy delivery.

K Bush1, R Townson, S Zavgorodni.   

Abstract

RapidArc radiotherapy technology from Varian Medical Systems is one of the most complex delivery systems currently available, and achieves an entire intensity-modulated radiation therapy (IMRT) treatment in a single gantry rotation about the patient. Three dynamic parameters can be continuously varied to create IMRT dose distributions-the speed of rotation, beam shaping aperture and delivery dose rate. Modeling of RapidArc technology was incorporated within the existing Vancouver Island Monte Carlo (VIMC) system (Zavgorodni et al 2007 Radiother. Oncol. 84 S49, 2008 Proc. 16th Int. Conf. on Medical Physics). This process was named VIMC-Arc and has become an efficient framework for the verification of RapidArc treatment plans. VIMC-Arc is a fully automated system that constructs the Monte Carlo (MC) beam and patient models from a standard RapidArc DICOM dataset, simulates radiation transport, collects the resulting dose and converts the dose into DICOM format for import back into the treatment planning system (TPS). VIMC-Arc accommodates multiple arc IMRT deliveries and models gantry rotation as a series of segments with dynamic MLC motion within each segment. Several verification RapidArc plans were generated by the Eclipse TPS on a water-equivalent cylindrical phantom and re-calculated using VIMC-Arc. This includes one 'typical' RapidArc plan, one plan for dual arc treatment and one plan with 'avoidance' sectors. One RapidArc plan was also calculated on a DICOM patient CT dataset. Statistical uncertainty of MC simulations was kept within 1%. VIMC-Arc produced dose distributions that matched very closely to those calculated by the anisotropic analytical algorithm (AAA) that is used in Eclipse. All plans also demonstrated better than 1% agreement of the dose at the isocenter. This demonstrates the capabilities of our new MC system to model all dosimetric features required for RapidArc dose calculations.

Entities:  

Mesh:

Year:  2008        PMID: 18758001     DOI: 10.1088/0031-9155/53/19/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Independent calculation of monitor units for VMAT and SPORT.

Authors:  Xin Chen; Karl Bush; Aiping Ding; Lei Xing
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

Review 2.  Monte Carlo systems used for treatment planning and dose verification.

Authors:  Lorenzo Brualla; Miguel Rodriguez; Antonio M Lallena
Journal:  Strahlenther Onkol       Date:  2016-11-25       Impact factor: 3.621

3.  Handling of uncertainty in medical data using machine learning and probability theory techniques: a review of 30 years (1991-2020).

Authors:  Roohallah Alizadehsani; Mohamad Roshanzamir; Sadiq Hussain; Abbas Khosravi; Afsaneh Koohestani; Mohammad Hossein Zangooei; Moloud Abdar; Adham Beykikhoshk; Afshin Shoeibi; Assef Zare; Maryam Panahiazar; Saeid Nahavandi; Dipti Srinivasan; Amir F Atiya; U Rajendra Acharya
Journal:  Ann Oper Res       Date:  2021-03-21       Impact factor: 4.820

4.  Assessing the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy.

Authors:  Juan Diego Azcona; Lei Xing; Xin Chen; Karl Bush; Ruijiang Li
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-04-01       Impact factor: 7.038

5.  The impact of dose calculation algorithms on partial and whole breast radiation treatment plans.

Authors:  Parminder S Basran; Sergei Zavgorodni; Tanya Berrang; Ivo A Olivotto; Wayne Beckham
Journal:  Radiat Oncol       Date:  2010-12-16       Impact factor: 3.481

6.  Single fraction radiosurgery using Rapid Arc for treatment of intracranial targets.

Authors:  Hendrik A Wolff; Daniela M Wagner; Hans Christiansen; Clemens F Hess; Hilke Vorwerk
Journal:  Radiat Oncol       Date:  2010-09-13       Impact factor: 3.481

7.  Two years experience with quality assurance protocol for patient related Rapid Arc treatment plan verification using a two dimensional ionization chamber array.

Authors:  Daniela Wagner; Hilke Vorwerk
Journal:  Radiat Oncol       Date:  2011-02-22       Impact factor: 3.481

8.  Independent absorbed-dose calculation using the Monte Carlo algorithm in volumetric modulated arc therapy.

Authors:  Akihiro Haga; Taiki Magome; Shigeharu Takenaka; Toshikazu Imae; Akira Sakumi; Akihiro Nomoto; Hiroshi Igaki; Kenshiro Shiraishi; Hideomi Yamashita; Kuni Ohtomo; Keiichi Nakagawa
Journal:  Radiat Oncol       Date:  2014-03-14       Impact factor: 3.481

9.  Critical appraisal of the accuracy of Acuros-XB and Anisotropic Analytical Algorithm compared to measurement and calculations with the compass system in the delivery of RapidArc clinical plans.

Authors:  Murugesan Kathirvel; Shanmuga Subramanian; Alessandro Clivio; Gandhi Arun; Antonella Fogliata; Giorgia Nicolini; Vellaiyan Subramani; Shanmugam Thirumalai Swamy; Eugenio Vanetti; Luca Cozzi
Journal:  Radiat Oncol       Date:  2013-06-11       Impact factor: 3.481

10.  Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans.

Authors:  Alanah M Bergman; Ermias Gete; Cheryl Duzenli; Tony Teke
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

View more