Literature DB >> 18756009

Comparison of electrical and magnetic stimulations to assess quadriceps muscle function.

Samuel Verges1, Nicola A Maffiuletti, Hugo Kerherve, Nicolas Decorte, Bernard Wuyam, Guillaume Y Millet.   

Abstract

This study aimed to 1) compare electrical and magnetic stimulations for quadriceps muscle function assessment, and 2) ascertain whether the ratios of the second twitch elicited by supramaximal electrical and magnetic femoral nerve stimulation at 10 and 100 Hz (T2(10:100)) and the total twitch force elicited by the same types of stimulations (Fpaired(10:100)) are equivalent to the standard low- to high-frequency force ratio associated with submaximal electrical tetanic stimulations (Ftet(10:100)). Quadriceps force and vastus lateralis EMG were recorded at rest (n = 21 subjects), immediately after, and 30 min after a 30-min downhill run (n = 10) when 1) supramaximal electrical nerve stimulation (ENS), 2) magnetic nerve stimulation (MNS) and 3) submaximal electrical muscle stimulation (EMS) were delivered in random order at 1 (single stimulation), 10, and 100 Hz (paired stimulations). Ten- and 100-Hz 500-ms tetani were also evoked with EMS to determine Ftet(10:100). Before exercise, contractile properties with single and paired stimulations were similar for ENS and MNS (all intraclass correlation coefficients k > 0.90), but smaller for EMS (P < 0.001). M-wave characteristics were also similar for ENS and MNS (all k > 0.90). After exercise, changes in all parameters did not differ between methods. With fatigue, the changes in Ftet(10:100) were inconsistently correlated with the changes in T2(10:100) (r(2) = 0.24-0.73, P = 0.002-0.15) but better correlated with the changes in Fpaired(10:100) (immediately after exercise: r(2) = 0.80-0.83, P < 0.001; 30 min after exercise: r(2) = 0.46-0.82, P = 0.001-0.03). We conclude that ENS and MNS provide similar quadriceps muscle function assessment, while Fpaired(10:100) is a better index than T2(10:100) of low- to high-frequency fatigue of the quadriceps in vivo.

Entities:  

Mesh:

Year:  2008        PMID: 18756009     DOI: 10.1152/japplphysiol.01051.2007

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  37 in total

1.  Magnetic versus electrical stimulation in the interpolation twitch technique of elbow flexors.

Authors:  Sofia I Lampropoulou; Alexander V Nowicky; Louise Marston
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

2.  Comparison of electrical nerve stimulation, electrical muscle stimulation and magnetic nerve stimulation to assess the neuromuscular function of the plantar flexor muscles.

Authors:  Daria Neyroud; John Temesi; Guillaume Y Millet; Samuel Verges; Nicola A Maffiuletti; Bengt Kayser; Nicolas Place
Journal:  Eur J Appl Physiol       Date:  2015-02-15       Impact factor: 3.078

Review 3.  The effect of blood flow occlusion during acute low-intensity isometric elbow flexion exercise.

Authors:  David B Copithorne; Charles L Rice
Journal:  Eur J Appl Physiol       Date:  2019-02-08       Impact factor: 3.078

4.  Fatigue after short (100-m), medium (200-m) and long (400-m) treadmill sprints.

Authors:  K Tomazin; J B Morin; V Strojnik; A Podpecan; G Y Millet
Journal:  Eur J Appl Physiol       Date:  2011-07-07       Impact factor: 3.078

5.  The development of peripheral fatigue and short-term recovery during self-paced high-intensity exercise.

Authors:  Christian Froyd; Guillaume Y Millet; Timothy D Noakes
Journal:  J Physiol       Date:  2012-12-10       Impact factor: 5.182

6.  New device for nonvolitional evaluation of quadriceps force in ventilated patients.

Authors:  Franco Laghi; Najeeb Khan; Thimothy Schnell; Dinas Aleksonis; Kendra Hammond; Hameeda Shaikh; Eileen Collins; Amal Jubran; Martin J Tobin
Journal:  Muscle Nerve       Date:  2017-12-11       Impact factor: 3.217

7.  Corticospinal excitability is altered similarly following concentric and eccentric maximal contractions.

Authors:  Pierre Clos; Yoann Garnier; Alain Martin; Romuald Lepers
Journal:  Eur J Appl Physiol       Date:  2020-04-28       Impact factor: 3.078

8.  Neuromuscular and perceptual responses during repeated cycling sprints-usefulness of a "hypoxic to normoxic" recovery approach.

Authors:  Jacky Soo; François Billaut; David J Bishop; Ryan J Christian; Olivier Girard
Journal:  Eur J Appl Physiol       Date:  2020-02-21       Impact factor: 3.078

9.  High-intensity exhaustive exercise reduces long-interval intracortical inhibition.

Authors:  Thomas J O'Leary; Johnny Collett; Martyn G Morris
Journal:  Exp Brain Res       Date:  2018-08-25       Impact factor: 1.972

10.  Sex differences in central and peripheral mechanisms of fatigue in cyclists.

Authors:  Beth W Glace; Ian J Kremenic; Malachy P McHugh
Journal:  Eur J Appl Physiol       Date:  2012-10-23       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.