Literature DB >> 11764349

Cementless femoral revision arthroplasty of the hip: minimum 5 years followup.

J R Moreland1, M A Moreno.   

Abstract

Durable fixation of the femoral component to the bone in femoral revision arthroplasty of the hip is the main ingredient to a successful reconstruction. Because of poor durability of cemented fixation in revision, in 1984, one author began to use cementless fixation with extensively porous-coated chrome cobalt stems. The current authors report the durability of that fixation technique in 137 hips (134 patients) followed up 5 to 16 years. With a mean followup of 9.3 years, 10 (7%) of the stems have been removed. Five (4%) were removed for fixation problems and five (4%) were removed for infection. Using the radiographic criteria of Engh et al, 83% of the stems achieved bony ingrowth. No late failure of fixation was observed. Canal-filling prostheses were more likely to have bone ingrowth as were stems placed in femurs with lesser degrees of bone stock deficiency. Significant thigh pain was seen in 7% of bone ingrown stems, 16% of stable fibrous fixated stems, and 75% of unstable stems. Significant thigh pain in bone ingrown stems was observed more commonly in osteoporotic femurs and bone stock deficient femurs. Severe stress shielding correlated with preoperative osteoporosis and larger diameter stems but has not caused failure. Excellent durability of this fixation technique is evident.

Entities:  

Mesh:

Year:  2001        PMID: 11764349     DOI: 10.1097/00003086-200112000-00022

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  20 in total

1.  Distal locking stem for revision femoral loosening and peri-prosthetic fractures.

Authors:  Patrice Mertl; Remy Philippot; Philippe Rosset; Henri Migaud; Jacques Tabutin; Denis Van de Velde
Journal:  Int Orthop       Date:  2010-12-24       Impact factor: 3.075

2.  Are short fully coated stems adequate for "simple" femoral revisions?

Authors:  Matthew W Tetreault; Sanjai K Shukla; Paul H Yi; Scott M Sporer; Craig J Della Valle
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

3.  Femoral revision with an extensively hydroxyapatite-coated femoral component.

Authors:  Lawrence V Gulotta; Andreas Baldini; Kristin Foote; Stephen Lyman; Bryan J Nestor
Journal:  HSS J       Date:  2007-12-01

4.  Increase of cortical bone after a cementless long stem in periprosthetic fractures.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos; Rosário Madero
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

5.  Bone remodeling after a mean of 10 years in diaphyseal cortical defects repaired with femoral revision using bypass fixation of extensively porous-coated stems with high stiffness.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tanzo Sugimori; Toru Ichiseki; Tadami Matsumoto
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-01-04

Review 6.  Femoral revision with primary cementless stems: a systematic review of the literature.

Authors:  Luca Cavagnaro; Matteo Formica; Marco Basso; Andrea Zanirato; Stefano Divano; Lamberto Felli
Journal:  Musculoskelet Surg       Date:  2017-07-01

7.  Femoral revision surgery using a fully hydroxyapatite-coated stem: a cohort study of twenty two to twenty seven years.

Authors:  Olav Reikerås
Journal:  Int Orthop       Date:  2016-04-30       Impact factor: 3.075

8.  What is the long-term survival of impaction allografting of the femur?

Authors:  Kevin L Garvin; Beau S Konigsberg; Natalie D Ommen; Elizabeth R Lyden
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

9.  Extensively coated revision stems in proximally deficient femur: early results in 15 patients.

Authors:  S K S Marya; R Thukral
Journal:  Indian J Orthop       Date:  2008-07       Impact factor: 1.251

10.  Large femoral bone loss after hip revision using the uncemented proximally porous-coated Bi-Metric prosthesis: 22 hips followed for a mean of 6 years.

Authors:  Per Y Adolphson; Mats O F Salemyr; Olof G Sköldenberg; Henrik S G Bodén
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.