Minimizing superficial thermal injury using bilateral cryogen spray cooling during laser reshaping of composite cartilage grafts.

Cheng-Jen Chang1, Sally M H Cheng, Lynn L Chiu, Brian J F Wong, Keen Ting.   

Abstract

Composite cartilage grafts were excised from New Zealand rabbit ears. Flat composite grafts (of cartilage and overlying skin graft on both surfaces) were obtained from each ear and cut into a rectangle measuring 50 mm by 25 mm (x by y) with an average thickness of approximately 1.3 mm (z), skin included. Specimens were manually deformed with a jig and maintained in this new position during laser illumination. The composite cartilage grafts were illuminated on the concave surface with an Nd:YAG laser (1,064 nm, 3 mm spot) at 10 W, 20 W, 30 W, 40 W, 50 W. Cryogen spray cooling (CSC) was applied to both exterior (convex) and interior (concave) surfaces of the tissue to reduce thermal injury to the grafts. CSC was delivered: (1) in controlled applications (cryogen released when surface reached 40 degrees C, and (2) receiving only laser at above wattage, no CSC [representing the control group]. The specimens were maintained in a deformation for 15 minutes after illumination and serially examined for 14 days. The control group with no CSC caused injury to all specimens, ranging from minor to full thickness epidermal thermal injury. Although most levels of laser and CSC yielded a high degree of reshaping over an acute time period, after 14 days specimens exposed to 30 W, 40 W, 50 W retained shape better than those treated at 10 W and 20 W. The specimens exposed to 50 W with controlled CSC retained its new shape to the highest degree over all others, and thermal injury was minimal. In conclusion, combinations of laser and CSC parameters were effective and practical for the reshaping of composite cartilage grafts.

Entities:  

Mesh:

Year:  2008        PMID: 18727025      PMCID: PMC4122116          DOI: 10.1002/lsm.20652

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  20 in total

Review 1.  Laser reshaping of cartilage.

Authors:  E Sobol; A Sviridov; A Omel'chenko; V Bagratashvili; M Kitai; S E Harding; N Jones; K Jumel; M Mertig; W Pompe; Y Ovchinnikov; A Shekhter; V Svistushkin
Journal:  Biotechnol Genet Eng Rev       Date:  2000

2.  Laser-mediated cartilage reshaping with feedback-controlled cryogen spray cooling: biophysical properties and viability.

Authors:  A M Karamzadeh; A Rasouli; B S Tanenbaum; T E Milner; J S Nelson; B J Wong
Journal:  Lasers Surg Med       Date:  2001       Impact factor: 4.025

3.  [Otoplasty using the CO2 laser].

Authors:  H Stark
Journal:  Laryngorhinootologie       Date:  1991-11       Impact factor: 1.057

4.  Cryogen spray cooling and pulsed dye laser treatment of cutaneous hemangiomas.

Authors:  C J Chang; K M Kelly; J S Nelson
Journal:  Ann Plast Surg       Date:  2001-06       Impact factor: 1.539

5.  In vitro ear cartilage shaping with carbon dioxide laser: an experimental study.

Authors:  G A Velegrakis; C E Papadakis; A A Nikolidakis; E P Prokopakis; M E Volitakis; I Naoumidi; E S Helidonis
Journal:  Ann Otol Rhinol Laryngol       Date:  2000-12       Impact factor: 1.547

Review 6.  Active skin cooling in conjunction with laser dermatologic surgery.

Authors:  J S Nelson; B Majaron; K M Kelly
Journal:  Semin Cutan Med Surg       Date:  2000-12

7.  Wound healing and soft tissue effects of CO2, contact Nd: YAG and combined CO2-Nd: YAG laser beams on rabbit trachea.

Authors:  J Laranne; A Lagerstedt; J Pukander; I Rantala
Journal:  Acta Otolaryngol       Date:  1997-11       Impact factor: 1.494

8.  Epidermal protection with cryogen spray cooling during high fluence pulsed dye laser irradiation: an ex vivo study.

Authors:  J W Tunnell; J S Nelson; J H Torres; B Anvari
Journal:  Lasers Surg Med       Date:  2000       Impact factor: 4.025

9.  A prospective randomised study of laser reshaping of cartilage in vivo.

Authors:  N Jones; A Sviridov; E Sobol; A Omelchenko; J Lowe
Journal:  Lasers Med Sci       Date:  2001       Impact factor: 3.161

10.  Cryogen spray cooling for spatially selective photocoagulation of hemangiomas: a new methodology with preliminary clinical reports.

Authors:  C J Chang; B Anvari; J S Nelson
Journal:  Plast Reconstr Surg       Date:  1998-08       Impact factor: 4.730

View more
  6 in total

1.  Preliminary investigations on therapy thresholds for laser dosimetry, cryogen spray cooling duration, and treatment cycles for laser cartilage reshaping in the New Zealand white rabbit auricle.

Authors:  Cara A Chlebicki; Dmitry E Protsenko; Brian J Wong
Journal:  Lasers Med Sci       Date:  2013-11-08       Impact factor: 3.161

2.  The effects of laser irradiation of cartilage on chondrocyte gene expression and the collagen matrix.

Authors:  Paul K Holden; Chao Li; Victor Da Costa; Chung-Ho Sun; Susan V Bryant; David M Gardiner; Brian J F Wong
Journal:  Lasers Surg Med       Date:  2009-09       Impact factor: 4.025

3.  Continuous cooling system in conjunction with laser surgery for ear reshaping.

Authors:  Yen-Chang Hsiao; Kuen Ting; Yun-Liang Su; Cheng-Jen Chang
Journal:  Lasers Med Sci       Date:  2019-07-01       Impact factor: 3.161

4.  In vivo laser cartilage reshaping with carbon dioxide spray cooling in a rabbit ear model: a pilot study.

Authors:  Edward C Kuan; Ashley A Hamamoto; Victor Sun; Tony Nguyen; Cyrus T Manuel; Dmitry E Protsenko; Brian J F Wong; J Stuart Nelson; Wangcun Jia
Journal:  Lasers Surg Med       Date:  2014-11-18       Impact factor: 4.025

5.  Minimally invasive ear reshaping with a 1450-nm diode laser using cryogen spray cooling in New Zealand white rabbits.

Authors:  Paul K Holden; Cara Chlebicki; Brian J F Wong
Journal:  Arch Facial Plast Surg       Date:  2009 Nov-Dec

6.  Ex vivo investigations of laser auricular cartilage reshaping with carbon dioxide spray cooling in a rabbit model.

Authors:  Edward C Wu; Victor Sun; Cyrus T Manuel; Dmitriy E Protsenko; Wangcun Jia; J Stuart Nelson; Brian J F Wong
Journal:  Lasers Med Sci       Date:  2013-01-10       Impact factor: 3.161

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.