Literature DB >> 11430436

Laser-mediated cartilage reshaping with feedback-controlled cryogen spray cooling: biophysical properties and viability.

A M Karamzadeh1, A Rasouli, B S Tanenbaum, T E Milner, J S Nelson, B J Wong.   

Abstract

BACKGROUND AND
OBJECTIVE: Recent studies have indicated that chondrocyte viability decreases with prolonged or repeated laser irradiation. To optimize laser-mediated cartilage reshaping, the heating process must be finely controlled. In this study, we use high-power Nd:YAG laser irradiation (lambda = 1.32 microm) combined with cryogen spray cooling (CSC) in an attempt to reshape porcine septal cartilage while enhancing chondrocyte viability. STUDY DESIGN/
MATERIALS AND METHODS: Chondrocyte viability was determined after high-power (50 W/cm2) Nd:YAG-mediated cartilage reshaping with and without cryogen spray cooling (CSC) and correlated with dynamic measurements of tissue optical and thermal properties.
RESULTS: After 1.5 to 2.0 seconds of laser exposure, characteristic changes in diffuse reflectance (indicating the onset of accelerated stress relaxation) was observed in both laser only and laser with CSC specimens. After 2 seconds of laser exposure, specimens in both groups retained the curved shape for up to 14 days. After one laser exposure, chondrocyte viability was 94.35 +/- 6.1% with CSC and 68.77 +/- 20.1% (P < 0.05) without CSC. After two laser exposures, a similar trend was observed with CSC (70.18 +/- 16.44%) opposed to without CSC (28 +/- 45%; P < 0.05).
CONCLUSION: CSC during high-power laser irradiation allows rapid heating while minimizing extreme front surface temperature elevations and axial thermal gradients. Laser irradiation with CSC can be used to effectively reshape cartilage tissue with the additional advantage of increasing chondrocyte viability.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11430436     DOI: 10.1002/1096-9101(2001)28:1<1::AID-LSM1009>3.0.CO;2-B

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  3 in total

1.  Preliminary investigations on therapy thresholds for laser dosimetry, cryogen spray cooling duration, and treatment cycles for laser cartilage reshaping in the New Zealand white rabbit auricle.

Authors:  Cara A Chlebicki; Dmitry E Protsenko; Brian J Wong
Journal:  Lasers Med Sci       Date:  2013-11-08       Impact factor: 3.161

2.  Minimally invasive ear reshaping with a 1450-nm diode laser using cryogen spray cooling in New Zealand white rabbits.

Authors:  Paul K Holden; Cara Chlebicki; Brian J F Wong
Journal:  Arch Facial Plast Surg       Date:  2009 Nov-Dec

3.  Minimizing superficial thermal injury using bilateral cryogen spray cooling during laser reshaping of composite cartilage grafts.

Authors:  Cheng-Jen Chang; Sally M H Cheng; Lynn L Chiu; Brian J F Wong; Keen Ting
Journal:  Lasers Surg Med       Date:  2008-09       Impact factor: 4.025

  3 in total