Literature DB >> 18714228

Muscular outputs during dynamic bench press under stable versus unstable conditions.

Sentaro Koshida1, Yukio Urabe, Koji Miyashita, Kanzunori Iwai, Aya Kagimori.   

Abstract

Previous studies have suggested that resistance training exercise under unstable conditions decreases the isometric force output, yet little is known about its influence on muscular outputs during dynamic movement. The objective of this study was to investigate the effect of an unstable condition on power, force, and velocity outputs during the bench press. Twenty male collegiate athletes (mean age, 21.3 +/- 1.5 years; mean height, 167.7 +/- 7.7 cm; mean weight, 75.9 +/- 17.5 kg) participated in this study. Each subject attempted 3 sets of single bench presses with 50% of 1 repetition maximum (1RM) under a stable condition with a flat bench and an unstable condition with a Swiss ball. Acceleration data were obtained with an accelerometer attached to the center of a barbell shaft, and peak outputs of power, force, and velocity were computed. Although significant loss of the peak outputs was found under the unstable condition (p < 0.017), their reduction rates remained relatively low, approximately 6% for force and 10% for power and velocity outputs, compared with previous findings. Such small reduction rates of muscular outputs may not compromise the training effect. Prospective studies are necessary to confirm whether the resistance training under an unstable condition permits the improvement of dynamic performance and trunk stability.

Mesh:

Year:  2008        PMID: 18714228     DOI: 10.1519/JSC.0b013e31817b03a1

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  11 in total

1.  The effectiveness of resistance training using unstable surfaces and devices for rehabilitation.

Authors:  David Behm; Juan Carlos Colado
Journal:  Int J Sports Phys Ther       Date:  2012-04

2.  Electromyographic analysis of trunk-muscle activity during stable, unstable and unilateral bridging exercises in healthy individuals.

Authors:  F M Feldwieser; L Sheeran; A Meana-Esteban; V Sparkes
Journal:  Eur Spine J       Date:  2012-03-15       Impact factor: 3.134

3.  Using bench press load to predict upper body exercise loads in physically active individuals.

Authors:  Del P Wong; Kwan-Lung Ngo; Michael A Tse; Andrew W Smith
Journal:  J Sports Sci Med       Date:  2013-03-01       Impact factor: 2.988

4.  Effects of instability versus traditional resistance training on strength, power and velocity in untrained men.

Authors:  José Luis Maté-Muñoz; Antonio J Antón Monroy; Pablo Jodra Jiménez; Manuel V Garnacho-Castaño
Journal:  J Sports Sci Med       Date:  2014-09-01       Impact factor: 2.988

Review 5.  Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review.

Authors:  Valentina Camomilla; Elena Bergamini; Silvia Fantozzi; Giuseppe Vannozzi
Journal:  Sensors (Basel)       Date:  2018-03-15       Impact factor: 3.576

6.  Alterations of Muscular Strength and Left and Right Limb Balance in Weightlifters after an 8-week Balance Training Program.

Authors:  Sung Hwun Kang; Cheol Woo Kim; Young Il Kim; Kwi Baek Kim; Sung Soo Lee; Ki Ok Shin
Journal:  J Phys Ther Sci       Date:  2013-08-20

Review 7.  Effects of Strength Training Using Unstable Surfaces on Strength, Power and Balance Performance Across the Lifespan: A Systematic Review and Meta-analysis.

Authors:  David G Behm; Thomas Muehlbauer; Armin Kibele; Urs Granacher
Journal:  Sports Med       Date:  2015-12       Impact factor: 11.136

8.  Force production during squats performed with a rotational resistance device under stable versus unstable conditions.

Authors:  Gerard Moras; Jairo Vázquez-Guerrero
Journal:  J Phys Ther Sci       Date:  2015-11-30

9.  Instability resistance training across the exercise continuum.

Authors:  David G Behm; Juan C Colado; Juan C Colado
Journal:  Sports Health       Date:  2013-11       Impact factor: 3.843

10.  Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads.

Authors:  Jairo Vázquez-Guerrero; Gerard Moras; Jennifer Baeza; Sergio Rodríguez-Jiménez
Journal:  PLoS One       Date:  2016-04-25       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.