Fracture force of tooth-tooth- and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments.

Carola Kolbeck1, Michael Behr, Martin Rosentritt, Gerhard Handel.   

Abstract

OBJECTIVES: Tooth-coloured customised implant abutments and full ceramic supraconstructions thereon can be made of zirconia by computer-aided manufacturing (CAM). The aim of this study was to examine the potential limits of zirconia three-unit fixed partial dentures made on customised zirconia implant abutments in implant-tooth supported cases.
MATERIAL AND METHODS: Rigidly mounted implants (XiVE-S diameter 3.8 mm; length 11 mm; Friadent, Germany) were placed in PMMA-moulds pairwise with human molars at a distance of 10 mm in groups #1 and #2. Control group #3 consisted of two molars without implant involvement. Beforehand all molar roots were covered with polyether (Impregum: 3 M Espe, Germany) to simulate periodontal mobility. The abutments in #1 were individually fabricated from CerconBase and luted on experimental titanium bases (both: DeguDent, Germany). In #2, industrially prefabricated titanium abutments (Friadent) were used. All molar teeth were provided with a circumferential chamfer preparation. Three-unit fixed partial dentures were fabricated from CerconBase/CerconKiss in a CAM-process (Material/devices: DeguDent) for all test groups (n=8/group). All fixed partial dentures were cemented with RelyXUnicem (3 M Espe), thermomechanically loaded (TCML=1.2 x 10(6) x 50 N; 6000 x 5 degrees /55 degrees) and fracture tested in a Universal Test Machine (UTM 1446: Zwick, Germany).
RESULTS: None of the dentures failed during TCML, and the Cercon abutments showed no damage either to the bonding surface to titanium or to the ceramic itself. Two fixation screws in group #1 broke towards the end of TCML. Fracture test result (Median and 25-/75-Percentiles) were: #1 1190 (1046/2008), #2 991 (832/1402), #3 1331 (1224/1428).
CONCLUSIONS: All restoration alternatives showed sufficient fracture resistance for posterior regions.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18707604     DOI: 10.1111/j.1600-0501.2008.01551.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crowns.

Authors:  Frank P Nothdurft; Klaus E Doppler; Kurt J Erdelt; Andreas W Knauber; Peter R Pospiech
Journal:  Clin Oral Investig       Date:  2010-01-19       Impact factor: 3.573

2.  Load-bearing capacity of artificially aged zirconia fixed dental prostheses with heterogeneous abutment supports.

Authors:  Katia Sarafidou; Meike Stiesch; Marc Philipp Dittmer; Daniela Jörn; Lothar Borchers; Philipp Kohorst
Journal:  Clin Oral Investig       Date:  2011-05-24       Impact factor: 3.573

3.  Mechanical stability of angulated zirconia abutments supporting maxillary anterior single crowns on narrow-diameter implants.

Authors:  Ruiyang Ma; Ping Yu; Yuqiang Zhang; Chenyang Xie; Xin Tan; Jikui Sun; Haiyang Yu
Journal:  Clin Oral Investig       Date:  2022-09-26       Impact factor: 3.606

4.  Fracture behaviour of implant-implant- and implant-tooth-supported all-ceramic fixed dental prostheses utilising zirconium dioxide implant abutments.

Authors:  Frank Philipp Nothdurft; Sabine Merker; Peter Reinhard Pospiech
Journal:  Clin Oral Investig       Date:  2010-01-05       Impact factor: 3.573

5.  Fracture behavior of all-ceramic, implant-supported, and tooth-implant-supported fixed dental prostheses.

Authors:  Abdul Rahman Alkharrat; Marc Schmitter; Stefan Rues; Peter Rammelsberg
Journal:  Clin Oral Investig       Date:  2017-12-02       Impact factor: 3.573

Review 6.  The use of PEEK in digital prosthodontics: A narrative review.

Authors:  Ioannis Papathanasiou; Phophi Kamposiora; George Papavasiliou; Marco Ferrari
Journal:  BMC Oral Health       Date:  2020-08-02       Impact factor: 2.757

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.