Literature DB >> 17650554

Technical requirements, biophysical considerations and protocol optimization with magnetic resonance angiography using blood-pool agents.

Martin Rohrer1, Liesbeth Geerts-Ossevoort, Gerhard Laub.   

Abstract

In order to maximize the potential benefits of contrast-enhanced magnetic resonance angiography, careful attention must be paid to the choice of hardware, data acquisition and processing, and to the choice of contrast agent. Typically, contrast-enhanced magnetic resonance angiography uses parallel-imaging techniques, which shorten the acquisition time, enhance spatial resolution and reduce artefacts. The timing of data acquisition is crucial for maximal enhancement of the arteries: for optimal arterial depiction, the centre of k-space should be acquired at the time of peak concentration of contrast agent in the arterial bed being investigated, and a number of k-space acquisition techniques are available to achieve this. SENSE or GRAPPA techniques can be used to facilitate parallel-imaging reconstruction of either the image data or k-space data, respectively. Gadolinium contrast agents shorten the proton relaxation times (most importantly T1) of blood, thereby increasing the signal-to-noise ratio and enhancing differentiation between blood vessels and other tissues. The blood-pool (intravascular) contrast agent gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is reversibly protein-bound in human plasma. This results in a marked increase in relaxivity, and hence a strong T1 shortening effect compared with other gadolinium-based contrast agents. Furthermore, the blood retention time of gadofosveset trisodium is substantially prolonged compared with conventional contrast agents. As a result, gadofosveset trisodium permits both first-pass and steady-state imaging.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17650554

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  2 in total

1.  A noncontrast-enhanced pulse sequence optimized to visualize human peripheral vessels.

Authors:  Kjell-Inge Gjesdal; Tryggve Storaas; Jonn-Terje Geitung
Journal:  Eur Radiol       Date:  2008-08-15       Impact factor: 5.315

2.  Diagnostic accuracy of contrast-enhanced MR angiography in severe carotid stenosis: meta-analysis with metaregression of different techniques.

Authors:  Jan Menke
Journal:  Eur Radiol       Date:  2009-04-28       Impact factor: 5.315

  2 in total