Literature DB >> 18700367

Influence of abutment material on stability of peri-implant tissues: a systematic review.

Tomas Linkevicius1, Peteris Apse.   

Abstract

PURPOSE: The aim of this systematic review was to evaluate available evidence for a difference in the stability of peri-implant tissues between titanium abutments versus gold alloy, zirconium oxide, or aluminum oxide abutments.
MATERIALS AND METHODS: Studies were identified by examining several electronic databases and major dental implant, prosthetic, and periodontal journals. To be selected for the preliminary article pool, the article must have been written in the English language and published from 1980 to March 2007. Articles were sorted based on the nature of the study. In vitro studies and literature reviews were excluded. The included articles were clinical, human histology, and animal studies. Case reports, case series, uncontrolled clinical trials, and clinical studies with teeth treated as a control were excluded from the final review.
RESULTS: The initial article pool included 40 articles of which 9 met the inclusion criteria: 3 animal studies, 2 human histological studies, and 4 randomized clinical trials. Soft tissue recession was not accurately measured in the included clinical studies. Assessment of peri-implant tissues around zirconium oxide and titanium abutments was described only in animal and human histologic studies. Due to differences in study types, timing of follow-ups, and outcome variables, meta-analysis could not be performed.
CONCLUSIONS: Included studies revealed that titanium abutments did not maintain a higher bone level in comparison to gold alloy, aluminum oxide, or zirconium oxide abutments. However, there is a lack of information about the clinical performance of zirconium oxide and gold alloy abutments as compared to titanium abutments.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18700367

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  21 in total

1.  Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crowns.

Authors:  Frank P Nothdurft; Klaus E Doppler; Kurt J Erdelt; Andreas W Knauber; Peter R Pospiech
Journal:  Clin Oral Investig       Date:  2010-01-19       Impact factor: 3.573

2.  Fracture behavior of zirconia implant abutments is influenced by superstructure-geometry.

Authors:  Frank P Nothdurft; Konrad Neumann; Andreas W Knauber
Journal:  Clin Oral Investig       Date:  2013-09-20       Impact factor: 3.573

3.  A pre-clinical murine model of oral implant osseointegration.

Authors:  S Mouraret; D J Hunter; C Bardet; J B Brunski; P Bouchard; J A Helms
Journal:  Bone       Date:  2013-07-23       Impact factor: 4.398

4.  Mechanical stability of angulated zirconia abutments supporting maxillary anterior single crowns on narrow-diameter implants.

Authors:  Ruiyang Ma; Ping Yu; Yuqiang Zhang; Chenyang Xie; Xin Tan; Jikui Sun; Haiyang Yu
Journal:  Clin Oral Investig       Date:  2022-09-26       Impact factor: 3.606

5.  Immediate definitive individualized abutments reduce peri-implant bone loss: a randomized controlled split-mouth study on 16 patients.

Authors:  M Erhan Çömlekoğlu; Nejat Nizam; Mine Dündar Çömlekoğlu
Journal:  Clin Oral Investig       Date:  2017-05-31       Impact factor: 3.573

6.  Fracture behaviour of implant-implant- and implant-tooth-supported all-ceramic fixed dental prostheses utilising zirconium dioxide implant abutments.

Authors:  Frank Philipp Nothdurft; Sabine Merker; Peter Reinhard Pospiech
Journal:  Clin Oral Investig       Date:  2010-01-05       Impact factor: 3.573

7.  Soft and Hard Tissue Management in Implant Therapy-Part II: Prosthetic Concepts.

Authors:  Paolo Francesco Manicone; Luca Raffaelli; Marjan Ghassemian; Antonio D'Addona
Journal:  Int J Biomater       Date:  2012-07-03

8.  Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis.

Authors:  Peter Gehrke; Astrid Tabellion; Carsten Fischer
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

9.  Interaction of titanium, zirconia and lithium disilicate with peri-implant soft tissue: study protocol for a randomized controlled trial.

Authors:  Katharina Kuhn; Heike Rudolph; Michael Graf; Matthias Moldan; Shaoxia Zhou; Martin Udart; Andrea Böhmler; Ralph G Luthardt
Journal:  Trials       Date:  2015-10-15       Impact factor: 2.279

10.  Peri-implant soft tissue management: Where are we?

Authors:  Neel Bhatavadekar
Journal:  J Indian Soc Periodontol       Date:  2012-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.