Literature DB >> 18692631

Durability of hand-sewn valves in the right ventricular outlet.

Graham R Nunn1, Jayme Bennetts, Ella Onikul.   

Abstract

OBJECTIVE: The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet.
METHODS: We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement.
RESULTS: A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained competent with regurgitant fractions of only 5% to 30% (magnetic resonance imaging angiography), and this has remained stable with time. The maximum follow-up for these valves is 5 years. No stenosis or peripheral emboli have been recognized, and no valves have been replaced to date.
CONCLUSION: Hand-sewn bileaflet polytetrafluoroethylene valves in the right ventricular outlet can reliably provide competence and maintain function in the medium term. Their shape and size allow placement in young children with a reasonable expectation that they will remain competent with growth of the native annulus and not require replacement. Their durability is superior to the pericardial and polytetrafluoroethylene monocusp valves in this series.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18692631     DOI: 10.1016/j.jtcvs.2008.02.063

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

1.  Perioperative care of children with tetralogy of fallot.

Authors:  Satish K Rajagopal; Ravi R Thiagarajan
Journal:  Curr Treat Options Cardiovasc Med       Date:  2011-10

2.  Short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of Fallot.

Authors:  Prashant Ramdas Wankhade; Neeraj Aggarwal; Reena Khantwal Joshi; Mridul Agarwal; Raja Joshi; Ashwani Mehta; Sibashankar Kar
Journal:  Ann Pediatr Cardiol       Date:  2019 Jan-Apr

3.  Trileaflet semilunar valve reconstruction: pulsatile in vitro evaluation.

Authors:  Lisa Carlson Hanse; Marcell J Tjørnild; Simon G Sørensen; Peter Johansen; Ignacio Lugones; Vibeke E Hjortdal
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-09-09

4.  Short-term outcome of Polytetrafluoroethylene Membrane Valve versus Transannular Pericardial patch Reconstruction of Right Ventricular Outflow Tract in Tetralogy of Fallot: a Randomized Controlled Trial.

Authors:  Sanjib Rawat; Vivek Jaswal; Shyam Kumar Singh Thingnam; Harkant Singh; Sachin Mahajan; Reuben Lamiaki Kynta; Goverdhan Dutt Puri; Manoj Kumar Rohit
Journal:  Braz J Cardiovasc Surg       Date:  2021-02-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.