Literature DB >> 18675201

Effect of self-etchant pH on the shear bond strength of orthodontic brackets.

Adam W Ostby1, Samir E Bishara, Gerald E Denehy, John F Laffoon, John J Warren.   

Abstract

INTRODUCTION: Self-etching primers (SEPs) have been used successfully during bonding to reduce technique sensitivity while minimizing the etching of enamel. Although serving the same purpose, SEPs differ in acidity and aggressiveness. Thus, the purpose of this study was to determine whether the pH of SEPs affects the shear bond strength of orthodontic brackets.
METHODS: Forty-five molars were cleaned, mounted, and randomly divided into 3 groups with different SEPs: in group 1 (control), 15 orthodontic brackets were bonded to the teeth with Transbond Plus (3M Unitek, Monrovia, Calif) with a pH of about 1.0; in group 2, 15 brackets were bonded with Adper Prompt L-Pop (3M ESPE, St Paul, Minn) with a pH of 0.9 to 1.0; in group 3, 15 brackets were bonded with Clearfil S3 Bond (Kuraray America, New York, NY), with a pH of 2.7. All teeth were bonded with Transbond XT paste (3M Unitek). The teeth were debonded within half an hour after initial bonding by using a universal testing machine. The residual adhesive on each tooth was evaluated. ANOVA was used to compare the shear bond strength (SBS) of the 3 groups, and the chi-square test was used to compare the adhesive remnant index (ARI) scores for the 3 groups.
RESULTS: ANOVA indicated significant differences between the groups. The Duncan multiple range test indicated that Clearfil S3 Bond produced a significantly stronger mean SBS (6.5 +/- 1.9 MPa) than the Transbond Plus system (mean, 4.2 +/- 1.9 MPa). No significant differences were seen between the SBS of the brackets bonded with Adper (mean, 5.9 +/- 3.4 MPa) and the other 2 groups. The comparisons of the ARI scores between the 3 groups indicated that bracket failure mode was not significantly different.
CONCLUSIONS: The SEP with the highest pH (least acidic), Clearfil S3 Bond, bonded brackets successfully and with the strongest SBS; this suggests that the pH of the SEP is not the primary determinant of the SBS. The clinician should be aware that some SEPs can leave the enamel surface healthier after debonding.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18675201     DOI: 10.1016/j.ajodo.2006.07.039

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  11 in total

1.  Shear bond strengths of seven self-etching primers after thermo-cycling.

Authors:  L Brauchli; M Zeller; A Wichelhaus
Journal:  J Orofac Orthop       Date:  2011-10-06       Impact factor: 1.938

2.  Shear bond strength of orthodontic brackets bonded with a new self-adhering flowable resin composite.

Authors:  Cecilia Goracci; Mariam Margvelashvili; Agostino Giovannetti; Alessandro Vichi; Marco Ferrari
Journal:  Clin Oral Investig       Date:  2012-04-27       Impact factor: 3.573

3.  Influence of self-etch all-in-one adhesives on fissure sealant shear bond strength under contaminated enamel conditions.

Authors:  A Coelho; J P Canta; J N R Martins; S Arantes-Oliveira; P F Marques
Journal:  Eur Arch Paediatr Dent       Date:  2018-10-16

4.  Self-etch adhesives for the bonding of orthodontic brackets: faster, stronger, safer?

Authors:  Timea Lamper; Nicoleta Ilie; Karin C Huth; Ingrid Rudzki; Andrea Wichelhaus; Ekaterini Paschos
Journal:  Clin Oral Investig       Date:  2013-02-14       Impact factor: 3.573

5.  The effects of application time of a self-etching primer and debonding methods on bracket bond strength.

Authors:  Brandon C Parrish; Thomas R Katona; Serkis C Isikbay; Kelton T Stewart; Katherine S Kula
Journal:  Angle Orthod       Date:  2011-07-28       Impact factor: 2.079

6.  The Effect of Energy Densities on the Shear Bond Strength of Self-Adhering Flowable Composite to Er:YAG Pretreated Dentin.

Authors:  Paul Nahas; Toni Zeinoun; Zeina Majzoub; Karim Corbani; Samir Nammour
Journal:  Biomed Res Int       Date:  2016-10-17       Impact factor: 3.411

7.  Bracket bonding to polymethylmethacrylate-based materials for computer-aided design/manufacture of temporary restorations: Influence of mechanical treatment and chemical treatment with universal adhesives.

Authors:  Cecilia Goracci; Mutlu Özcan; Lorenzo Franchi; Giuseppe Di Bello; Chris Louca; Alessandro Vichi
Journal:  Korean J Orthod       Date:  2019-11-26       Impact factor: 1.372

8.  Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons.

Authors:  Ahmet Yalçın Güngör; Huseyin Alkis; Hakan Turkkahraman
Journal:  Korean J Orthod       Date:  2013-04-25       Impact factor: 1.372

9.  Comparison of Shear Bond Strength of New Self-etching Primer with Conventional Self-etching Primers: An In-vitro Study.

Authors:  Abhinay Sorake; Rohan Rai; Gautham Hegde; Ridhima Suneja; Naveena Kumar; Jibin Skaria
Journal:  J Int Oral Health       Date:  2015-07

10.  Shear bond strength and debonding characteristics of a new premixed self-etching with a reference total-etch adhesive.

Authors:  Michael Schauseil; Sonja Blöcher; Andreas Hellak; Matthias J Roggendorf; Steffen Stein; Heike Korbmacher-Steiner
Journal:  Head Face Med       Date:  2016-04-30       Impact factor: 2.151

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.