Literature DB >> 18669958

The anatomical tibial axis: reliable rotational orientation in knee replacement.

J P Cobb1, H Dixon, W Dandachli, F Iranpour.   

Abstract

The rotational alignment of the tibia is an unresolved issue in knee replacement. A poor functional outcome may be due to malrotation of the tibial component. Our aim was to find a reliable method for positioning the tibial component in knee replacement. CT scans of 19 knees were reconstructed in three dimensions and orientated vertically. An axial plane was identified 20 mm below the tibial spines. The centre of each tibial condyle was calculated from ten points taken round the condylar cortex. The tibial tubercle centre was also generated as the centre of the circle which best fitted eight points on the outside of the tubercle in an axial plane at the level of its most prominent point. The derived points were identified by three observers with errors of 0.6 mm to 1 mm. The medial and lateral tibial centres were constant features (radius 24 mm (SD 3), and 22 mm (SD 3), respectively). An anatomical axis was created perpendicular to the line joining these two points. The tubercle centre was found to be 20 mm (SD 7) lateral to the centre of the medial tibial condyle. Compared with this axis, an axis perpendicular to the posterior condylar axis was internally rotated by 6 degrees (SD 3). An axis based on the tibial tubercle and the tibial spines was also internally rotated by 5 degrees (sd 10). Alignment of the knee when based on this anatomical axis was more reliable than either the posterior surfaces or any axis involving the tubercle which was the least reliable landmark in the region.

Entities:  

Mesh:

Year:  2008        PMID: 18669958     DOI: 10.1302/0301-620X.90B8.19905

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  46 in total

1.  Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty.

Authors:  Dongwook Kim; Sang Cheol Seong; Myung Chul Lee; Sahnghoon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-06       Impact factor: 4.342

2.  Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty.

Authors:  Stephen M Howell; Justin Chen; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-05       Impact factor: 4.342

3.  Centre of the posterior cruciate ligament and the sulcus between tubercle spines are reliable landmarks for tibial component placement.

Authors:  Namık Sahin; Teoman Atıcı; Ünal Kurtoğlu; Ali Turgut; Güven Ozkaya; Yüksel Ozkan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-03       Impact factor: 4.342

4.  Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Alfonso Noriega-Fernandez; Jose Manuel Fernandez-Carreira; Jose Manuel Fernandez-Simon; Jimena Llorens de los Rios
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-26       Impact factor: 4.342

5.  Design rationale for customized TKA: a new idea or revisiting the past?

Authors:  Evan M Schwechter; Wolfgang Fitz
Journal:  Curr Rev Musculoskelet Med       Date:  2012-12

6.  Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error.

Authors:  Csaba Forster-Horvath; Valerie Kremo; Magdalena Müller-Gerbl; Andrej Maria Nowakowski
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

7.  Rotational alignment of the tibial component in total knee arthroplasty: the anterior tibial cortex is a reliable landmark.

Authors:  Andrea Baldini; Pier Francesco Indelli; Lapo DE Luca; Pierpaolo Cerulli Mariani; Massimiliano Marcucci
Journal:  Joints       Date:  2014-03-21

8.  Computational model-based probabilistic analysis of in vivo material properties for ligament stiffness using the laxity test and computed tomography.

Authors:  Kyoung-Tak Kang; Sung-Hwan Kim; Juhyun Son; Young Han Lee; Heoung-Jae Chun
Journal:  J Mater Sci Mater Med       Date:  2016-10-27       Impact factor: 3.896

9.  Patient-specific positioning guides do not consistently achieve the planned implant position in UKA.

Authors:  Justin A M J van Leeuwen; Stephan M Röhrl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-12       Impact factor: 4.342

10.  Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border.

Authors:  Jörg Lützner; Frank Krummenauer; Klaus-Peter Günther; Stephan Kirschner
Journal:  BMC Musculoskelet Disord       Date:  2010-03-25       Impact factor: 2.362