Literature DB >> 18655986

Grading nuclear cataract opacity by densitometry and objective optical analysis.

Dolores Ortiz1, Jorge L Alió, Jose Ruiz-Colechá, Ulrike Oser.   

Abstract

PURPOSE: To evaluate the optical quality and densitometric characteristics in eyes with early stages of crystalline lens opacification.
SETTING: Vissum-Instituto de Oftalmológico de Alicante, Alicante, Spain.
METHODS: The study included 34 eyes of 24 consecutive patients with nuclear opacity (NO) between NO1 and NO3 on the Lens Opacities Classification System III, normal corneas, and no previous ocular surgery. Intraocular aberrations were obtained by subtraction between the total and corneal optical aberrations. Modulation transfer function (MTF) was measured using a double-pass device. Lens photography and density (optical density units, Scheimpflug photography) were also evaluated. The main outcome measures were (1) spatial frequencies at 0.5 MTF and the cutoff point and (2) intraocular total and lower- and higher-order aberrations (root mean square).
RESULTS: There was an increase in lens density with the cataract grade (mean 96.7 +/- 26.0 [SD], grade NO1; 125.1 +/- 25.9, grade NO2; 167.3 +/- 40.6, grade NO3). No statistically significant differences were found in intraocular higher aberrations between groups. Significant negative correlations were found between lens density and the spatial frequency at 0.5 MTF (r = -0.400, P = .026) or the cutoff MTF (r = -0.480, P = .006).
CONCLUSIONS: The optical quality of eyes degraded with increasing cataract grade due to morphological changes such as an increase in lens density. Scheimpflug photography and MTF analysis helped objectively characterize early to moderate grades of nuclear cataract.

Entities:  

Mesh:

Year:  2008        PMID: 18655986     DOI: 10.1016/j.jcrs.2008.04.022

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system.

Authors:  Ai-Lian Hu; Li-Ya Qiao; Ye Zhang; Xiao-Gu Cai; Lei Li; Xiu-Hua Wan
Journal:  Int J Ophthalmol       Date:  2015-10-18       Impact factor: 1.779

2.  Correlation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataracts.

Authors:  Fernando Faria-Correia; Bernardo Lopes; Tiago Monteiro; Nuno Franqueira; Renato Ambrósio
Journal:  Int Ophthalmol       Date:  2017-05-26       Impact factor: 2.031

3.  Repeatability and reproducibility of a double-pass optical quality analysis device.

Authors:  Chen-Chen Xu; Ting Xue; Qin-Mei Wang; Yi-Ni Zhou; Jin-Hai Huang; A-Yong Yu
Journal:  PLoS One       Date:  2015-02-03       Impact factor: 3.240

4.  Application of different Scheimpflug-based lens densitometry methods in phacodynamics prediction.

Authors:  Fernando Faria-Correia; Bernardo T Lopes; Isaac C Ramos; Tiago Monteiro; Nuno Franqueira; Renato Ambrósio
Journal:  Clin Ophthalmol       Date:  2016-04-06

5.  Assessment of Optical Quality at Different Contrast Levels in Pseudophakic Eyes.

Authors:  Chang Won Park; Hyojin Kim; Choun-Ki Joo
Journal:  J Ophthalmol       Date:  2016-01-28       Impact factor: 1.909

6.  Wavefront aberrations and retinal image quality in different lenticular opacity types and densities.

Authors:  Cheng-Zhe Wu; Hua Jin; Zhen-Nv Shen; Ying-Jun Li; Xun Cui
Journal:  Sci Rep       Date:  2017-11-10       Impact factor: 4.379

7.  Utility of the optical quality analysis system for decision-making in cataract surgery.

Authors:  Jin Sun Hwang; Yoon Pyo Lee; Seok Hyun Bae; Ha Kyoung Kim; Kayoung Yi; Young Joo Shin
Journal:  BMC Ophthalmol       Date:  2018-09-03       Impact factor: 2.209

8.  Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

Authors:  Mi Tian; Huamao Miao; Yang Shen; Jian Gao; Xiaofen Mo; Xingtao Zhou
Journal:  PLoS One       Date:  2015-11-04       Impact factor: 3.240

9.  Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique.

Authors:  Abu-Bakar Zafar; Richard C Chu; Miranda N Bishara; Mujtaba A Qazi; Ashraf M Mahmoud; Jay S Pepose
Journal:  Clin Ophthalmol       Date:  2020-05-26

10.  Using Optical Quality Analysis System for predicting surgical parameters in age-related cataract patients.

Authors:  Thibaud Garcin; Damien Grivet; Gilles Thuret; Philippe Gain
Journal:  PLoS One       Date:  2020-10-12       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.