Literature DB >> 18653687

Complete intracranial arterial and venous blood flow evaluation with 4D flow MR imaging.

M D Hope1, D D Purcell, T A Hope, C von Morze, D B Vigneron, M T Alley, W P Dillon.   

Abstract

SUMMARY: Time-resolved, 3D velocity-encoded MR imaging (4D Flow) allows for the acquisition of dynamic, multidirectional data on blood flow and has recently been used for the evaluation of intracranial arterial flow. Using a 3T system with optimization of both temporal resolution and k-space subsampling with a combination of parallel imaging and cut-corner acquisition, we present the clinical assessment of a patient with an arteriovenous malformation by providing complete intracranial arterial and venous coverage in a reasonable scan time.

Entities:  

Mesh:

Year:  2008        PMID: 18653687     DOI: 10.3174/ajnr.A1138

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  24 in total

1.  Automatic labeling of cerebral arteries in magnetic resonance angiography.

Authors:  Tora Dunås; Anders Wåhlin; Khalid Ambarki; Laleh Zarrinkoob; Richard Birgander; Jan Malm; Anders Eklund
Journal:  MAGMA       Date:  2015-12-08       Impact factor: 2.310

2.  Fast 4D flow MRI re-emerges as a potential clinical tool for neuroradiology.

Authors:  P Turski; M Edjlali; C Oppenheim
Journal:  AJNR Am J Neuroradiol       Date:  2013-06-27       Impact factor: 3.825

3.  Nonenhanced ECG-gated time-resolved 4D steady-state free precession (SSFP) MR angiography (MRA) for assessment of cerebral collateral flow: comparison with digital subtraction angiography (DSA).

Authors:  Rotem Shlomo Lanzman; Patric Kröpil; Peter Schmitt; Xiaoming Bi; Michael Gliem; Falk R Miese; Daniel Hänggi; Marcel Kamp; Axel Scherer; Bernd Turowski; Dirk Blondin
Journal:  Eur Radiol       Date:  2011-01-12       Impact factor: 5.315

4.  In vivo analysis of physiological 3D blood flow of cerebral veins.

Authors:  Florian Schuchardt; Laure Schroeder; Constantin Anastasopoulos; Michael Markl; Jochen Bäuerle; Anja Hennemuth; Johann Drexl; José M Valdueza; Irina Mader; Andreas Harloff
Journal:  Eur Radiol       Date:  2015-02-01       Impact factor: 5.315

5.  Evaluation of 4D vascular flow and tissue perfusion in cerebral arteriovenous malformations: influence of Spetzler-Martin grade, clinical presentation, and AVM risk factors.

Authors:  C Wu; S A Ansari; A R Honarmand; P Vakil; M C Hurley; B R Bendok; J Carr; T J Carroll; M Markl
Journal:  AJNR Am J Neuroradiol       Date:  2015-02-26       Impact factor: 3.825

6.  Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI.

Authors:  Stephan Meckel; Lorenz Leitner; Leo H Bonati; Francesco Santini; Tilman Schubert; Aurelien F Stalder; Philippe Lyrer; Michael Markl; Stephan G Wetzel
Journal:  Neuroradiology       Date:  2012-11-10       Impact factor: 2.804

7.  Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms.

Authors:  Jing Liu; Louise Koskas; Farshid Faraji; Evan Kao; Yan Wang; Henrik Haraldsson; Sarah Kefayati; Chengcheng Zhu; Sinyeob Ahn; Gerhard Laub; David Saloner
Journal:  MAGMA       Date:  2017-08-07       Impact factor: 2.310

8.  Accelerated analysis of three-dimensional blood flow of the thoracic aorta in stroke patients.

Authors:  Thomas Wehrum; Miriam Kams; Laure Schroeder; Johann Drexl; Anja Hennemuth; Andreas Harloff
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-15       Impact factor: 2.357

9.  Influence of eddy current, Maxwell and gradient field corrections on 3D flow visualization of 3D CINE PC-MRI data.

Authors:  Ramona Lorenz; Jelena Bock; Jeff Snyder; Jan G Korvink; Bernd A Jung; Michael Markl
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

10.  Measuring pulsatile flow in cerebral arteries using 4D phase-contrast MR imaging.

Authors:  A Wåhlin; K Ambarki; R Birgander; O Wieben; K M Johnson; J Malm; A Eklund
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-14       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.