Literature DB >> 15381620

Use of a diathermy system in thyroid surgery.

Andreas Kiriakopoulos1, Tsakayannis Dimitrios, Linos Dimitrios.   

Abstract

HYPOTHESIS: New hemostatic methods have been widely used in open and laparoscopic surgery. The LigaSure Precise diathermy system (Valleylab, Boulder, Colo) has been recently used in thyroid surgery. We hypothesized that its use could lead to reduced operative time and fewer complications compared with conventional knot tying in total or near-total thyroidectomy.
DESIGN: Prospective case-controlled study.
SETTING: Tertiary care private hospital. PATIENTS: Eighty patients underwent total or near-total thyroidectomy by 1 surgeon.
INTERVENTIONS: Forty patients underwent thyroidectomy with the conventional knot tying technique and 40 patients with the LigaSure diathermy system. MAIN OUTCOME MEASURES: Demographics, histopathological diagnosis, operative time, intraoperative blood loss, complications, and cost, using chi2 test and Wilcoxon rank sum test.
RESULTS: The study groups had similar demographic and histopathological characteristics. The mean +/- SD operative time was nonsignificantly reduced in the LigaSure group compared with the conventional knot tying group (84 +/- 6 vs 89 +/- 7 minutes, P = .60). The mean +/- SD intraoperative blood loss was less for the LigaSure group (30 +/- 5 vs 35 +/- 8 mL, P = .36). There was 1 case of transient recurrent laryngeal nerve palsy in the LigaSure group. One patient from this group and 2 patients from the other group exhibited transient hypocalcemia; permanent postoperative hypocalcemia was not encountered in either group. The cost of the LigaSure diathermy system was significantly greater than that of conventional knot tying.
CONCLUSION: Use of the LigaSure in thyroid surgery did not significantly reduce operative time, blood loss, or complication rates compared with conventional knot tying, but it increased operative cost.

Entities:  

Mesh:

Year:  2004        PMID: 15381620     DOI: 10.1001/archsurg.139.9.997

Source DB:  PubMed          Journal:  Arch Surg        ISSN: 0004-0010


  20 in total

1.  The use of "harmonic scalpel" versus "knot tying" for conventional "open" thyroidectomy: results of a prospective randomized study.

Authors:  Celestino Pio Lombardi; Marco Raffaelli; Americo Cicchetti; Marco Marchetti; Carmela De Crea; Rossella Di Bidino; Luigi Oragano; Rocco Bellantone
Journal:  Langenbecks Arch Surg       Date:  2008-07-15       Impact factor: 3.445

2.  Thyroid surgery with harmonic focus, ligasure precise and conventional technique: a retrospective case-matched study.

Authors:  A Bove; Ig Papanikolaou; G Bongarzoni; Pa Mattei; H Markogiannakis; M Chatzipetrou; V D'Addetta; Rm Di Renzo; M Fiordaliso; L Corbellini
Journal:  Hippokratia       Date:  2012-04       Impact factor: 0.471

3.  Bipolar thermofusion vessel sealing system (TVS) versus conventional vessel ligation (CVL) in thyroid surgery--results of a prospective study.

Authors:  Pier Francesco Alesina; Thomas Rolfs; Martin K Walz
Journal:  Langenbecks Arch Surg       Date:  2010-02       Impact factor: 3.445

4.  Thyroidectomy with LigaSure.

Authors:  Mile Ignjatović; Zoran Kostić
Journal:  Surg Today       Date:  2011-05-28       Impact factor: 2.549

5.  Harmonic versus LigaSure hemostasis technique in thyroid surgery: A meta-analysis.

Authors:  Arun Upadhyaya; Tianpeng Hu; Zhaowei Meng; Xue Li; Xianghui He; Weijun Tian; Qiang Jia; Jian Tan
Journal:  Biomed Rep       Date:  2016-05-26

6.  Blood loss and contributing factors in femoral fracture surgery.

Authors:  I Kajja; G S Bimenya; B Eindhoven; H Jan Ten Duis; C T S Sibinga
Journal:  Afr Health Sci       Date:  2010-03       Impact factor: 0.927

7.  Clipless and sutureless endoscopic thyroidectomy using only the harmonic scalpel.

Authors:  Yoon Woo Koh; Jae Hong Park; Jae Wook Kim; Seung Won Lee; Eun Chang Choi
Journal:  Surg Endosc       Date:  2009-12-08       Impact factor: 4.584

8.  Use of BiClamp decreased the severity of hypocalcemia after total thyroidectomy compared with LigaSure: a prospective study.

Authors:  Elie Oussoultzoglou; Fabrizio Panaro; Edoardo Rosso; Ion Zeca; Philippe Bachellier; Patrick Pessaux; Daniel Jaeck
Journal:  World J Surg       Date:  2008-09       Impact factor: 3.352

9.  Use of a collagen-sealing device in hepatic resection: a comparative analysis to standard resection technique.

Authors:  T Cheang; S S Hanna; F C Wright; C H L Law
Journal:  HPB (Oxford)       Date:  2006       Impact factor: 3.647

10.  The impact of the Harmonic FOCUS™ on complications in thyroid surgery: a prospective multicenter study.

Authors:  Gabriele Materazzi; Giuseppe Caravaglios; Valeria Matteucci; Aleksandr Aghababyan; Mario Miccoli; Paolo Miccoli
Journal:  Updates Surg       Date:  2013-06-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.