Literature DB >> 18642881

Labeless immunosensor assay for prostate specific antigen with picogram per milliliter limits of detection based upon an ac impedance protocol.

Andrew C Barton1, Frank Davis, Séamus P J Higson.   

Abstract

This paper describes the development of labeless immunosensors for the prostate cancer marker prostate specific antigen (PSA). Poly(1,2-diaminobenzene) was electrodeposited onto screen-printed carbon electrodes, and this modified surface was sonochemically ablated to form a microelectrode array. Polyaniline was electropolymerized within these pores to form a microarray of conductive polyaniline protrusions. Two methods were utilized to immobilize antibodies for prostate specific antigen (APSA). The first involved entrapment of APSA during electropolymerization of the polyaniline. The second utilized a polyaniline array as a substrate to immobilize a biotinylated APSA using a classical avidin-biotin affinity approach. Microelectrode arrays were interrogated using ac impedance protocols before and following exposure to PSA solutions. Our preliminary results show that concentration/ac response relationships were recorded over very different ranges; sensors fabricated using an affinity approach exhibited detection limits 1000 times lower than those formulated by the entrapment method. This demonstrates that assembly protocols have major effects on immunosensor performance.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18642881     DOI: 10.1021/ac800491m

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2010-06-15       Impact factor: 6.986

2.  Autonomous magnetically actuated continuous flow microimmunofluorocytometry assay.

Authors:  Lawrence A Sasso; Akif Undar; Jeffrey D Zahn
Journal:  Microfluid Nanofluidics       Date:  2010-08-01       Impact factor: 2.529

3.  Continuous monitoring of inflammation biomarkers during simulated cardiopulmonary bypass using a microfluidic immunoassay device - a pilot study.

Authors:  Lawrence A Sasso; Kiana Aran; Yulong Guan; Akif Ündar; Jeffrey D Zahn
Journal:  Artif Organs       Date:  2013-01       Impact factor: 3.094

4.  Sonochemically fabricated microelectrode arrays for use as sensing platforms.

Authors:  Stuart D Collyer; Frank Davis; Séamus P J Higson
Journal:  Sensors (Basel)       Date:  2010-05-24       Impact factor: 3.576

5.  Use of data processing for rapid detection of the prostate-specific antigen biomarker using immunomagnetic sandwich-type sensors.

Authors:  Camila A Proença; Tayane A Freitas; Thaísa A Baldo; Elsa M Materón; Flávio M Shimizu; Gabriella R Ferreira; Frederico L F Soares; Ronaldo C Faria; Osvaldo N Oliveira
Journal:  Beilstein J Nanotechnol       Date:  2019-11-06       Impact factor: 3.649

Review 6.  Biosensors in clinical chemistry - 2011 update.

Authors:  Paul D'Orazio
Journal:  Clin Chim Acta       Date:  2011-06-26       Impact factor: 3.786

7.  Sensitive detection and glycoprofiling of a prostate specific antigen using impedimetric assays.

Authors:  D Pihíková; Š Belicky; P Kasák; T Bertok; J Tkac
Journal:  Analyst       Date:  2015-12-09       Impact factor: 4.616

8.  Aberrant sialylation of a prostate-specific antigen: Electrochemical label-free glycoprofiling in prostate cancer serum samples.

Authors:  Dominika Pihikova; Peter Kasak; Petra Kubanikova; Roman Sokol; Jan Tkac
Journal:  Anal Chim Acta       Date:  2016-07-01       Impact factor: 6.558

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.