Literature DB >> 18636218

Recollapse of previous vertebral compression fracture after percutaneous vertebroplasty.

D H Heo1, D K Chin, Y S Yoon, S U Kuh.   

Abstract

UNLABELLED: This study was undertaken to investigate the incidence rate, characteristics, and predisposing factors associated with recollapse of the same vertebrae after percutaneous vertebroplasty (PVP). Recollapse of the same vertebra after PVP is the one of the complications of the procedure, and the incidence rate in our study was 3.21%. The most important predisposing factor was pre-operative osteonecrosis. Recollapse was not related to trauma.
INTRODUCTION: PVP using polymethylmethacrylate has become a popular treatment for osteoporotic vertebral compression fracture. Recollapse of the same vertebrae after PVP has rarely been reported. This study was undertaken to investigate the incidence, characteristics, and predisposing factors associated with recollapse of the same vertebrae after PVP.
METHODS: Eleven patients (seven females and four males; mean age, 69.91 +/- 5.49 years), out of a total of 343 patients, developed recollapse of the same vertebra after PVP. The 11 patients who developed recollapse comprised the "recollapse group", while the remaining 332 patients comprised the "well-maintained group".
RESULTS: Pre-operative magnetic resonance imaging revealed that the incidence of osteonecrosis was significantly higher in the recollapse group than the well-maintained group (p < 0.05). The degree of re-expansion of the compressed vertebral body after PVP was significantly higher in the recollapse group than in the well-maintained group (p < 0.05).
CONCLUSIONS: The most important predisposing factor for recollapse was pre-operative osteonecrosis. Recollapse was not related to trauma. Osteoporotic vertebral compression fracture with osteonecrosis or pseudoarthrosis has been regarded as a relative indication for PVP; however, the findings of this study suggest that this disease category may be a relative contraindication for PVP.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18636218     DOI: 10.1007/s00198-008-0682-3

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  31 in total

1.  Repeated fracture of a vertebral body after treatment with balloon kyphoplasty: case illustration.

Authors:  Thabele Leslie-Mazwi; H Gordon Deen
Journal:  J Neurosurg Spine       Date:  2006-03

Review 2.  Delayed post-traumatic osteonecrosis of a vertebral body (Kummell's disease).

Authors:  W F Young; D Brown; A Kendler; D Clements
Journal:  Acta Orthop Belg       Date:  2002-02       Impact factor: 0.500

3.  Efficacy of postural reduction in osteoporotic vertebral compression fractures followed by percutaneous vertebroplasty.

Authors:  Dong-Kyu Chin; Young-Soo Kim; Yong-Eun Cho; Jun-Jae Shin
Journal:  Neurosurgery       Date:  2006-04       Impact factor: 4.654

4.  The therapeutic benefit of repeat percutaneous vertebroplasty at previously treated vertebral levels.

Authors:  John R Gaughen; Mary E Jensen; Patricia A Schweickert; William F Marx; David F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2002 Nov-Dec       Impact factor: 3.825

5.  Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects.

Authors:  M E Jensen; A J Evans; J M Mathis; D F Kallmes; H J Cloft; J E Dion
Journal:  AJNR Am J Neuroradiol       Date:  1997 Nov-Dec       Impact factor: 3.825

6.  Radiological follow-up of new compression fractures following percutaneous vertebroplasty.

Authors:  Noboru Tanigawa; Atsushi Komemushi; Shuji Kariya; Hiroyuki Kojima; Yuzo Shomura; Satoshi Sawada
Journal:  Cardiovasc Intervent Radiol       Date:  2006 Jan-Feb       Impact factor: 2.740

7.  Thermal characterization of PMMA-based bone cement curing.

Authors:  Chaodi Li; James Mason; Don Yakimicki
Journal:  J Mater Sci Mater Med       Date:  2004-01       Impact factor: 3.896

8.  Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis.

Authors:  Anita A Uppin; Joshua A Hirsch; Luis V Centenera; Bernard A Pfiefer; Artemis G Pazianos; In Sup Choi
Journal:  Radiology       Date:  2003-01       Impact factor: 11.105

Review 9.  Evolution of vertebroplasty: a biomechanical perspective.

Authors:  Kay Sun; Michael A K Liebschner
Journal:  Ann Biomed Eng       Date:  2004-01       Impact factor: 3.934

10.  Intravertebral vacuum phenomenon in osteoporotic compression fracture: report of 67 cases with quantitative evaluation of intravertebral instability.

Authors:  Dong-Yun Kim; Sang-Ho Lee; Jee Soo Jang; Sang Ki Chung; Ho-Yeon Lee
Journal:  J Neurosurg       Date:  2004-01       Impact factor: 5.115

View more
  58 in total

1.  Evaluation of pain reduction and height restoration post vertebral augmentation using a polyether ether ketone (PEEK) polymer implant for the treatment of split (Magerl A2) vertebral fractures: a prospective, long-term, non-randomized study.

Authors:  Georgios Velonakis; Dimitrios Filippiadis; Stavros Spiliopoulos; Elias Brountzos; Nikolaos Kelekis; Alexis Kelekis
Journal:  Eur Radiol       Date:  2018-12-03       Impact factor: 5.315

2.  The retrial of percutaneous vertebroplasty for the treatment of vertebral compression fracture.

Authors:  Han Woong Kim; Austin Kwon; Min Cheol Lee; Jae Wook Song; Sang Kyu Kim; In Hwan Kim
Journal:  J Korean Neurosurg Soc       Date:  2010-04-30

3.  Bone Cement-Augmented Percutaneous Short Segment Fixation: An Effective Treatment for Kummell's Disease?

Authors:  Seon Joo Park; Hyeun Sung Kim; Seok Ki Lee; Seok Won Kim
Journal:  J Korean Neurosurg Soc       Date:  2015-07-31

4.  What is the importance of "halo" phenomenon around bone cement following vertebral augmentation for osteoporotic compression fracture?

Authors:  K H Kim; S U Kuh; J Y Park; K S Kim; D K Chin; Y E Cho
Journal:  Osteoporos Int       Date:  2012-01-21       Impact factor: 4.507

5.  Analysis of risk factors of subsequent fractures after vertebroplasty.

Authors:  Gang Sun; Hai Tang; Min Li; Xunwei Liu; Peng Jin; Li Li
Journal:  Eur Spine J       Date:  2013-11-20       Impact factor: 3.134

6.  Short-term outcomes of percutaneous pedicle screw fixation combined with vertebroplasty: A minimally invasive treatment for Kümmell's disease with intravertebral instability.

Authors:  Chao Lou; Weiyang Yu; Zhenzhong Chen; Jiawei Gao; Feijun Liu; Dengwei He
Journal:  Acta Orthop Traumatol Turc       Date:  2020-11       Impact factor: 1.511

7.  Pedicle screw fixation with kyphoplasty decreases the fracture risk of the treated and adjacent non-treated vertebral bodies: a finite element analysis.

Authors:  Pan Yang; Ying Zhang; Huan-Wen Ding; Jian Liu; Lin-Qiang Ye; Jin Xiao; Qiang Tu; Tao Yang; Fei Wang; Guo-Gang Sun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2016-12-07

8.  Refracture of osteoporotic vertebral body concurrent with cement fragmentation at the previously treated vertebral level after balloon kyphoplasty: a case report.

Authors:  Xigong Li; Xianfeng Lou; Xiangjin Lin; Junhua Du
Journal:  Osteoporos Int       Date:  2014-02-20       Impact factor: 4.507

9.  Vertebroplasty and Kyphoplasty Can Restore Normal Spine Mechanics following Osteoporotic Vertebral Fracture.

Authors:  Jin Luo; Michael A Adams; Patricia Dolan
Journal:  J Osteoporos       Date:  2010-06-20

10.  Morphological changes of injected calcium phosphate cement in osteoporotic compressed vertebral bodies.

Authors:  H D Heo; Y J Cho; S H Sheen; S U Kuh; S M Cho; S M Oh
Journal:  Osteoporos Int       Date:  2009-12       Impact factor: 4.507

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.