Literature DB >> 24554341

Refracture of osteoporotic vertebral body concurrent with cement fragmentation at the previously treated vertebral level after balloon kyphoplasty: a case report.

Xigong Li1, Xianfeng Lou, Xiangjin Lin, Junhua Du.   

Abstract

Kyphoplasty has been shown to provide symptomatic relief of vertebral compression fractures refractory to medical therapy. However, few reports have focused on refracture of cemented vertebrae after kyphoplasty. The presence of cemented vertebrae refracture concurrent with cement fragmentation is an extremely rare condition. We reported an 86-year-old man with a T12 osteoporotic compression fracture undergoing the kyphoplasty treatment. The patient postoperatively continued to have back pain at the same level. The solid lumped polymethylmethacrylate (PMMA) mass and inadequate use and insufficient filling of PMMA cement were observed in postoperative radiographs and magnetic resonance image (MRI) examination. He refused to receive the surgical intervention, but had not strict compliance with oral anti-osteoporotic medications. Ten months postoperatively, refracture of osteoporotic vertebral body concurrent with cement fragmentation occurred at the previously kyphoplasty-treated vertebral level. Bone mineral analysis showed severe osteoporosis with a T-score of -4.0. The patient finally obtained therapeutic benefit of pain relief and bony union of T12 vertebral body by consistently adhering to anti-osteoporotic medication treatment. This case illustrated that patients who underwent kyphoplasty to treat osteoporotic vertebral compression fractures with intravertebral fracture should be strictly followed up and supervised in their anti-osteoporotic medication treatment. The interdigitation injection pattern of PMMA and sufficient PMMA filling with trabeculae in the kyphoplasty procedure also might prevent refracture of the cemented vertebrae concurrent with PMMA fragmentation.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24554341     DOI: 10.1007/s00198-014-2626-4

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  13 in total

1.  Is insufficient use of polymethylmethacrylate a cause for vertebroplasty failure necessitating repeat vertebroplasty?

Authors:  Louis Gilula
Journal:  AJNR Am J Neuroradiol       Date:  2003 Nov-Dec       Impact factor: 3.825

2.  Comparison of kyphoplasty and vertebroplasty for treatment of painful osteoporotic vertebral compression fractures: twelve-month follow-up in a prospective nonrandomized comparative study.

Authors:  Xigong Li; Huilin Yang; Tiansi Tang; Zhonglai Qian; Liang Chen; Zhigang Zhang
Journal:  J Spinal Disord Tech       Date:  2012-05

3.  Repeated fracture of a vertebral body after treatment with balloon kyphoplasty: case illustration.

Authors:  Thabele Leslie-Mazwi; H Gordon Deen
Journal:  J Neurosurg Spine       Date:  2006-03

4.  Refracture with cement extrusion following percutaneous vertebroplasty of a large interbody cleft.

Authors:  A L Wagner; E Baskurt
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

5.  Vertebroplasty versus kyphoplasty: biomechanical behavior under repetitive loading conditions.

Authors:  Mi Jung Kim; Derek P Lindsey; Matthew Hannibal; Todd F Alamin
Journal:  Spine (Phila Pa 1976)       Date:  2006-08-15       Impact factor: 3.468

6.  Repeated percutaneous vertebroplasty for refracture of cemented vertebrae.

Authors:  Lih-Huei Chen; Ming-Kai Hsieh; Jen-Chung Liao; Po-Liang Lai; Chi-Chien Niu; Tsai-Sheng Fu; Tsung-Ting Tsai; Wen-Jer Chen
Journal:  Arch Orthop Trauma Surg       Date:  2010-12-30       Impact factor: 3.067

Review 7.  Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies.

Authors:  Paul A Hulme; Jörg Krebs; Stephen J Ferguson; Ulrich Berlemann
Journal:  Spine (Phila Pa 1976)       Date:  2006-08-01       Impact factor: 3.468

8.  Recompression of vertebral body after balloon kyphoplasty for osteoporotic vertebral compression fracture.

Authors:  Young-Yul Kim; Kee-Won Rhyu
Journal:  Eur Spine J       Date:  2010-06-18       Impact factor: 3.134

9.  Prophylactic vertebroplasty may reduce the risk of adjacent intact vertebra from fatigue injury: an ex vivo biomechanical study.

Authors:  Chun-Kai Chiang; Yao-Hung Wang; Chung-Yi Yang; Been-Der Yang; Jaw-Lin Wang
Journal:  Spine (Phila Pa 1976)       Date:  2009-02-15       Impact factor: 3.468

10.  Recollapse of previous vertebral compression fracture after percutaneous vertebroplasty.

Authors:  D H Heo; D K Chin; Y S Yoon; S U Kuh
Journal:  Osteoporos Int       Date:  2008-07-18       Impact factor: 4.507

View more
  9 in total

1.  Lateral wedging of the cemented vertebra after balloon kyphoplasty: a case report.

Authors:  Heng Wang; Zhenzhong Sun; Joshi Nitesh; Huilin Yang; Weimin Jiang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

2.  Short-term outcomes of percutaneous pedicle screw fixation combined with vertebroplasty: A minimally invasive treatment for Kümmell's disease with intravertebral instability.

Authors:  Chao Lou; Weiyang Yu; Zhenzhong Chen; Jiawei Gao; Feijun Liu; Dengwei He
Journal:  Acta Orthop Traumatol Turc       Date:  2020-11       Impact factor: 1.511

3.  Anterior spinal fixation for recollapse of cemented vertebrae after percutaneous vertebroplasty.

Authors:  Narihito Nagoshi; Kentaro Fukuda; Masanobu Shioda; Masafumi Machida
Journal:  BMJ Case Rep       Date:  2016-03-18

4.  The impact of endplate fracture on postoperative vertebral height loss and kyphotic deformity during treatment of osteoporotic vertebral compression fractures with balloon kyphoplasty.

Authors:  Qingqing Li; Long Xiao; Jianwei Zhang; Jin Fan; Wei Zhou; Guoyong Yin; Yongxin Ren
Journal:  J Biomed Res       Date:  2016-07-20

5.  Kyphosis and canal compromise due to refracturing of an L1 cemented vertebra managed with posterior surgery alone.

Authors:  Abolfazl Rahimizadeh
Journal:  Surg Neurol Int       Date:  2019-11-01

6.  Prophylactic Percutaneous Kyphoplasty Treatment for Nonfractured Vertebral Bodies in Thoracolumbar for Osteoporotic Patients.

Authors:  Fei Lei; Wen He; Xinggui Tian; Zhongyang Li; Lipeng Zheng; Jianping Kang; Daxiong Feng
Journal:  Biomed Res Int       Date:  2020-04-09       Impact factor: 3.411

7.  Application of Titanium Alloy 3D-Printed Artificial Vertebral Body for Stage III Kümmell's Disease Complicated by Neurological Deficits.

Authors:  Chunke Dong; Hongyu Wei; Yuting Zhu; Jun Zhou; Haoning Ma
Journal:  Clin Interv Aging       Date:  2020-12-02       Impact factor: 4.458

8.  Relationship between sarcopenia/paravertebral muscles and the incidence of vertebral refractures following percutaneous kyphoplasty: a retrospective study.

Authors:  Qi Chen; Chenyang Lei; Tingxiao Zhao; Zhanqiu Dai; Jun Zhang; Yongming Jin; Chen Xia
Journal:  BMC Musculoskelet Disord       Date:  2022-09-22       Impact factor: 2.562

Review 9.  Refracture of osteoporotic vertebral body after treatment by balloon kyphoplasty: Three cases report.

Authors:  Xigong Li; Yang Lu; Xiangjin Lin
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.