L A Kurban1, L Gomersall, J Weir, P Wade. 1. Department of Radiology, Aberdeen Royal Infirmary, Aberdeen, UK. lutfi.kurban@abdn.ac.uk
Abstract
BACKGROUND: Computed tomography (CT) fluoroscopy nowadays is the most preferred method of guidance to perform percutaneous lung biopsy of pulmonary masses. Conventional fluoroscopy is an increasingly forgotten technique that still can be used to perform lung biopsies, with many advantages. PURPOSE: To compare the accuracy, safety, and effective dose (ED) of conventional fluoroscopy-guided needle lung biopsy (FNLB) with CT-guided needle lung biopsy procedures (CTNLB) reported in the literature. MATERIAL AND METHODS: 100 consecutive patients who underwent FNLB were reviewed retrospectively. Using the final histological diagnoses and the clinical and radiological course of the disease as references, the accuracy and sensitivity of FNLB were calculated. The complication rates of FNLB were assessed. Using computer software (XDOSE), the ED was calculated. The accuracy, complication rates, and the ED of FNLB were compared with CTNLB reported in the literature. RESULTS: The overall accuracy rate and sensitivity of FNLB were both 87%, which are comparable to the range of accuracies reported in the literature for CTNLB (74-97%). The complication rates of FNLB were also comparable to the complication rates reported for CTNLB. The commonest complication was pneumothorax, at a rate of 25%. The ED of FNLB was small, significantly lower than reported in the literature for CT-guided procedures. The mean ED of FNLB was 0.029 mSv, which is approximately equivalent to one chest X-ray. CONCLUSION: Conventional fluoroscopy is an accurate, safe, and low-dose alternative modality to CT to obtain an image-guided histological diagnosis of pulmonary lesions.
BACKGROUND: Computed tomography (CT) fluoroscopy nowadays is the most preferred method of guidance to perform percutaneous lung biopsy of pulmonary masses. Conventional fluoroscopy is an increasingly forgotten technique that still can be used to perform lung biopsies, with many advantages. PURPOSE: To compare the accuracy, safety, and effective dose (ED) of conventional fluoroscopy-guided needle lung biopsy (FNLB) with CT-guided needle lung biopsy procedures (CTNLB) reported in the literature. MATERIAL AND METHODS: 100 consecutive patients who underwent FNLB were reviewed retrospectively. Using the final histological diagnoses and the clinical and radiological course of the disease as references, the accuracy and sensitivity of FNLB were calculated. The complication rates of FNLB were assessed. Using computer software (XDOSE), the ED was calculated. The accuracy, complication rates, and the ED of FNLB were compared with CTNLB reported in the literature. RESULTS: The overall accuracy rate and sensitivity of FNLB were both 87%, which are comparable to the range of accuracies reported in the literature for CTNLB (74-97%). The complication rates of FNLB were also comparable to the complication rates reported for CTNLB. The commonest complication was pneumothorax, at a rate of 25%. The ED of FNLB was small, significantly lower than reported in the literature for CT-guided procedures. The mean ED of FNLB was 0.029 mSv, which is approximately equivalent to one chest X-ray. CONCLUSION: Conventional fluoroscopy is an accurate, safe, and low-dose alternative modality to CT to obtain an image-guided histological diagnosis of pulmonary lesions.
Authors: De Chao Jiao; Teng Fei Li; Xin Wei Han; Gang Wu; Ji Ma; Ming Ti Fu; Qi Sun; Janina Beilner Journal: Diagn Interv Radiol Date: 2014-11 Impact factor: 2.630
Authors: Kum Ju Chae; Hyunsook Hong; Soon Ho Yoon; Seokyung Hahn; Gong Yong Jin; Chang Min Park; Jin Mo Goo Journal: Sci Rep Date: 2019-08-27 Impact factor: 4.379
Authors: Soon Ho Yoon; Sang Min Lee; Chul Hwan Park; Jong Hyuk Lee; Hyungjin Kim; Kum Ju Chae; Kwang Nam Jin; Kyung Hee Lee; Jung Im Kim; Jung Hee Hong; Eui Jin Hwang; Heekyung Kim; Young Joo Suh; Samina Park; Young Sik Park; Dong Wan Kim; Miyoung Choi; Chang Min Park Journal: Korean J Radiol Date: 2020-11-19 Impact factor: 3.500
Authors: Geoffrey Hohert; Renelle Myers; Sylvia Lam; Andrei Vertikov; Anthony Lee; Stephen Lam; Pierre Lane Journal: J Biomed Opt Date: 2020-10 Impact factor: 3.170