Literature DB >> 18599429

Design and fabrication of PZN-7%PT single crystal high frequency angled needle ultrasound transducers.

Qifa Zhou, Dawei Wu, Jing Jin, Chang-hong Hu, Xiaochen Xu, Jay Williams, Jonathan M Cannata, Leongchew Lim, K Kirk Shung.   

Abstract

A high-frequency angled needle ultrasound transducer with an aperture size of 0.4 x 0.56 mm2 was fabricated using a lead zinc niobate-lead titanate (PZN- 7%PT) single crystal as the active piezoelectric material. The single crystal was bonded to a conductive silver particle matching layer and a conductive epoxy backing material through direct contact curing. A parylene outer matching layer was formed by vapor deposition. Angled needle probe configuration was achieved by dicing at 45 degrees to the single crystal poling direction to satisfy a clinical request for blood flow measurement in the posterior portion of the eye. The electrical impedance magnitude and phase of the transducer were 42 Omega and -63 degrees , respectively. The measured center frequency and the fractional bandwidth at -6 dB were 43 MHz and 45%, respectively. The two-way insertion loss was approximately 17 dB. Wire phantom imaging using fabricated PZN-7%PT single crystal transducers was obtained and spatial resolutions were assessed.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18599429      PMCID: PMC2717903          DOI: 10.1109/TUFFC.2008.804

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Elastic, piezoelectric, and dielectric properties of 0.955Pb(Zn(1/3)Nb(2/3))O(3)-0.45PbTiO(3 ) single crystal with designed multidomains.

Authors:  J Yin; B Jiang; W Cao
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2000       Impact factor: 2.725

2.  Single crystal PZN/PT-polymer composites for ultrasound transducer applications.

Authors:  T Ritter; X Geng; K Kirk Shung; P D Lopath; S E Park; T R Shrout
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2000       Impact factor: 2.725

3.  A high-frequency pulsed-wave Doppler ultrasound system for the detection and imaging of blood flow in the microcirculation.

Authors:  D A Christopher; P N Burns; B G Starkoski; F S Foster
Journal:  Ultrasound Med Biol       Date:  1997       Impact factor: 2.998

4.  PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application.

Authors:  Qifa Zhou; Xiaochen Xu; Emanuel J Gottlieb; Lei Sun; Jonathan M Cannata; Hossein Ameri; Mark S Humayun; Pengdi Han; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-03       Impact factor: 2.725

5.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

  5 in total
  8 in total

1.  Saturation effect in functional photoacoustic imaging.

Authors:  Jing Wang; Tan Liu; Shuliang Jiao; Ruimin Chen; Qifa Zhou; K Kirk Shung; Lihong V Wang; Hao F Zhang
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

2.  Relaxor-based ferroelectric single crystals: growth, domain engineering, characterization and applications.

Authors:  Enwei Sun; Wenwu Cao
Journal:  Prog Mater Sci       Date:  2014-08-01

3.  Relaxor-PT single crystals: observations and developments.

Authors:  Shujun Zhang; Thomas Shrout
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-10       Impact factor: 2.725

4.  A high-frequency, high frame rate duplex ultrasound linear array imaging system for small animal imaging.

Authors:  Lequan Zhang; Xiaochen Xu; Changhong Hu; Lei Sun; Jesse T Yen; Jonathan M Cannata; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-07       Impact factor: 2.725

5.  20 MHz forward-imaging single-element beam steering with an internal rotating variable-angle reflecting surface: Wire phantom and ex vivo pilot study.

Authors:  David T Raphael; Xiang Li; Jinhyoung Park; Ruimin Chen; Hamid Chabok; Arthur Barukh; Qifa Zhou; Mahmoud Elgazery; K Kirk Shung
Journal:  Ultrasonics       Date:  2012-10-12       Impact factor: 2.890

6.  Feasibility of rotational scan ultrasound imaging by an angled high frequency transducer for the posterior segment of the eye.

Authors:  Dong-Guk Paeng; Jin Ho Chang; Ruimin Chen; Mark S Humayun; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-03       Impact factor: 2.725

7.  Implementation of a rotational ultrasound biomicroscopy system equipped with a high-frequency angled needle transducer--ex vivo ultrasound imaging of porcine ocular posterior tissues.

Authors:  Tae-Hoon Bok; Juho Kim; Jinho Bae; Chong Hyun Lee; Dong-Guk Paeng
Journal:  Sensors (Basel)       Date:  2014-09-24       Impact factor: 3.576

8.  A 40-MHz Ultrasound Transducer with an Angled Aperture for Guiding Percutaneous Revascularization of Chronic Total Occlusion: A Feasibility Study.

Authors:  Junsu Lee; Jin Ho Chang
Journal:  Sensors (Basel)       Date:  2018-11-21       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.