Literature DB >> 1859755

Comparison of invasive and non-invasive measurements of continuous arterial pressure using the Finapres.

D N Stokes1, T Clutton-Brock, C Patil, J M Thompson, P Hutton.   

Abstract

A comparison was made of arterial pressures measured invasively from a radial arterial cannula and non-invasively from the middle finger using the 2300 Finapres (Ohmeda) during induction and maintenance of anaesthesia. Digital outputs of both pressures were captured directly onto computer hard disk; data recorded during flushing of the arterial line were excluded from analysis. We studied 53 patients undergoing cardiac, major vascular and neurosurgical procedures; 17705 comparisons of systolic, diastolic and mean pressure were analysed. Overall correlations between Finapres and invasive pressures were poor (r = 0.82, 0.68 and 0.78 for systolic, diastolic and mean pressures, respectively). The Finapres exhibited a high level of accuracy and precision in some recordings. However, patient data sets showed marked variability in average pressure differences (invasive minus Finapres) when examined individually or grouped by operation type. Unexplained variations in pressure difference with time and absolute pressure were observed also. Whilst providing useful beat-to-beat information on arterial pressure trends, the Finapres cannot be recommended as a universal substitute for invasive arterial pressure monitoring.

Entities:  

Mesh:

Year:  1991        PMID: 1859755     DOI: 10.1093/bja/67.1.26

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  10 in total

1.  Evaluation of noninvasive blood pressure recording by photoplethysmography in clinical studies using angiotensin challenges.

Authors:  T Buclin; C Buchwalder-Csajka; H R Brunner; J Biollaz
Journal:  Br J Clin Pharmacol       Date:  1999-10       Impact factor: 4.335

2.  Assessment of short-term blood pressure variability in anesthetized children: a comparative study between intraarterial and finger blood pressure.

Authors:  I Constant; D Laude; J L Elghozi; I Murat
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

3.  Beta-adrenergic receptor desensitization in man: insight into post-exercise attenuation of cardiac function.

Authors:  Emma Hart; Ellen Dawson; Peter Rasmussen; Keith George; Niels H Secher; Greg Whyte; Rob Shave
Journal:  J Physiol       Date:  2006-09-14       Impact factor: 5.182

4.  The reproducibility of cardiac baroreceptor activity assessed non-invasively by spectral sequence techniques.

Authors:  S L Dawson; T G Robinson; J H Youde; M A James; A Martin; P Weston; R Panerai; J F Potter
Journal:  Clin Auton Res       Date:  1997-12       Impact factor: 4.435

5.  Clinical evaluation of continuous noninvasive blood pressure monitoring: accuracy and tracking capabilities.

Authors:  C C Young; J B Mark; W White; A DeBree; J S Vender; A Fleming
Journal:  J Clin Monit       Date:  1995-07

6.  Accuracy of beat-to-beat noninvasive measurement of finger arterial pressure using the Finapres: a spectral analysis approach.

Authors:  V Novak; P Novak; R Schondorf
Journal:  J Clin Monit       Date:  1994-03

7.  Yohimbine in neurally mediated syncope. Pathophysiological implications.

Authors:  R Mosqueda-Garcia; R Fernandez-Violante; J Tank; M Snell; G Cunningham; R Furlan
Journal:  J Clin Invest       Date:  1998-11-15       Impact factor: 14.808

8.  Automated, continuous and non-invasive assessment of pulse pressure variations using CNAP® system.

Authors:  Matthieu Biais; Laurent Stecken; Aurélie Martin; Stéphanie Roullet; Alice Quinart; François Sztark
Journal:  J Clin Monit Comput       Date:  2016-06-16       Impact factor: 2.502

9.  Assessment of non-invasive ICP during CSF infusion test: an approach with transcranial Doppler.

Authors:  D Cardim; M Czosnyka; J Donnelly; C Robba; B C T Cabella; X Liu; M T Cabeleira; P Smielewsky; C Haubrich; M R Garnett; J D Pickard; Z Czosnyka
Journal:  Acta Neurochir (Wien)       Date:  2015-12-23       Impact factor: 2.216

10.  Inter-Day Reliability of Finapres ® Cardiovascular Measurements During Rest and Exercise.

Authors:  Mark Waldron; Stephen David Patterson; Owen Jeffries
Journal:  Sports Med Int Open       Date:  2017-11-17
  10 in total