Literature DB >> 18594348

Glaucoma affects steady state VEP contrast thresholds before psychophysics.

Anmar M A Rahman, Gordon F Sanderson.   

Abstract

PURPOSE: Frequency doubling technology (FDT) is a recent psychophysical test for glaucoma. It measures the contrast threshold to low spatial frequency, high temporal frequency sinusoidal luminance profile bars. We wanted to confirm, with stricter controls, Vaegan and Hollow's report that contrast thresholds of steady state visual evoked potentials (ssVEPs) to a stimulus resembling the central field of the FDT test was more sensitive to glaucoma than the subjective threshold to the same stimulus and to start to optimize the technique.
METHODS: A double masked trial using 57 eyes of 42 subjects. Both thresholds were estimated by modified binary search. In psychophysical testing, subjects were given a two alternative forced choice task. In ssVEP testing a significant signal in any one of eight channels was deemed to be a detection. In some subjects electrode positions were compared, both eyes were tested, tests were repeated to estimate reliability, stimulus frequencies were varied or full contrast functions were obtained.
RESULTS: Thresholds and percent abnormal increased as a function of glaucoma severity for ssVEPs but not for psychophysics. Both threshold measures were reliable. Interocular correlations were low. SsVEP amplitude against contrast functions had similar thresholds to those found by modified binary search. The data was too irregular for individual thresholds to be estimated from a fitted exponential. Amplitudes were greatest at 7 to 10 Hz, < or =6 cm above inion and least laterally. Noise was similar across electrodes.
CONCLUSIONS: SsVEP contrast thresholds to a stimulus like the central field of the FDT test detected glaucoma better than corresponding psychophysical thresholds at 18.29 Hz, when formal controls were used, as they had in a less controlled previous study at 7.14 Hz.

Entities:  

Mesh:

Year:  2008        PMID: 18594348     DOI: 10.1097/OPX.0b013e31817dba51

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  4 in total

1.  Steady-state multifocal visual evoked potential (ssmfVEP) using dartboard stimulation as a possible tool for objective visual field assessment.

Authors:  Folkert K Horn; Franziska Selle; Bettina Hohberger; Jan Kremers
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-11-09       Impact factor: 3.117

2.  Detecting Glaucoma With a Portable Brain-Computer Interface for Objective Assessment of Visual Function Loss.

Authors:  Masaki Nakanishi; Yu-Te Wang; Tzyy-Ping Jung; John K Zao; Yu-Yi Chien; Alberto Diniz-Filho; Fabio B Daga; Yuan-Pin Lin; Yijun Wang; Felipe A Medeiros
Journal:  JAMA Ophthalmol       Date:  2017-06-01       Impact factor: 7.389

3.  Visual evoked potential and psychophysical contrast thresholds in glaucoma.

Authors:  Siti Nurliyana Abdullah; Gordon F Sanderson; Andrew C James; Ted Maddess
Journal:  Doc Ophthalmol       Date:  2014-03-11       Impact factor: 2.379

4.  Steady-State Visually Evoked Potentials Elicited by Multifrequency Pattern-Reversal Stimulation.

Authors:  Bettina Hohberger; Jan Kremers; Folkert K Horn
Journal:  Transl Vis Sci Technol       Date:  2019-02-28       Impact factor: 3.283

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.