Importance: The current assessment of visual field loss in diseases such as glaucoma is affected by the subjectivity of patient responses and the lack of portability of standard perimeters. Objective: To describe the development and initial validation of a portable brain-computer interface (BCI) for objectively assessing visual function loss. Design, Setting, and Participants: This case-control study involved 62 eyes of 33 patients with glaucoma and 30 eyes of 17 healthy participants. Glaucoma was diagnosed based on a masked grading of optic disc stereophotographs. All participants underwent testing with a BCI device and standard automated perimetry (SAP) within 3 months. The BCI device integrates wearable, wireless, dry electroencephalogram and electrooculogram systems and a cellphone-based head-mounted display to enable the detection of multifocal steady state visual-evoked potentials associated with visual field stimulation. The performances of global and sectoral multifocal steady state visual-evoked potentials metrics to discriminate glaucomatous from healthy eyes were compared with global and sectoral SAP parameters. The repeatability of the BCI device measurements was assessed by collecting results of repeated testing in 20 eyes of 10 participants with glaucoma for 3 sessions of measurements separated by weekly intervals. Main Outcomes and Measures: Receiver operating characteristic curves summarizing diagnostic accuracy. Intraclass correlation coefficients and coefficients of variation for assessing repeatability.
Results: Among the 33 participants with glaucoma, 19 (58%) were white, 12 (36%) were black, and 2 (6%) were Asian, while among the 17 participants with healthy eyes, 9 (53%) were white, 8 (47%) were black, and none were Asian. The receiver operating characteristic curve area for the global BCI multifocal steady state visual-evoked potentials parameter was 0.92 (95% CI, 0.86-0.96), which was larger than for SAP mean deviation (area under the curve, 0.81; 95% CI, 0.72-0.90), SAP mean sensitivity (area under the curve, 0.80; 95% CI, 0.69-0.88; P = .03), and SAP pattern standard deviation (area under the curve, 0.77; 95% CI, 0.66-0.87; P = .01). No statistically significant differences were seen for the sectoral measurements between the BCI and SAP. Intraclass coefficients for global and sectoral parameters ranged from 0.74 to 0.92, and mean coefficients of variation ranged from 3.03% to 7.45%. Conclusions and Relevance: The BCI device may be useful for assessing the electrical brain responses associated with visual field stimulation. The device discriminated eyes with glaucomatous neuropathy from healthy eyes in a clinically based setting. Further studies should investigate the feasibility of the BCI device for home-based testing as well as for detecting visual function loss over time.

Entities:  

Mesh:

Year:  2017        PMID: 28448641      PMCID: PMC5772598          DOI: 10.1001/jamaophthalmol.2017.0738

Source DB:  PubMed          Journal:  JAMA Ophthalmol        ISSN: 2168-6165            Impact factor:   7.389


  43 in total

1.  Removing electroencephalographic artifacts by blind source separation.

Authors:  T P Jung; S Makeig; C Humphries; T W Lee; M J McKeown; V Iragui; T J Sejnowski
Journal:  Psychophysiology       Date:  2000-03       Impact factor: 4.016

Review 2.  Multifocal VEP and ganglion cell damage: applications and limitations for the study of glaucoma.

Authors:  Donald C Hood; Vivienne C Greenstein
Journal:  Prog Retin Eye Res       Date:  2003-03       Impact factor: 21.198

3.  Contrast-response functions of the multifocal steady-state VEP (MSV).

Authors:  S N Abdullah; M Y Boon; T Maddess
Journal:  Clin Neurophysiol       Date:  2012-03-22       Impact factor: 3.708

4.  A practical VEP-based brain-computer interface.

Authors:  Yijun Wang; Ruiping Wang; Xiaorong Gao; Bo Hong; Shangkai Gao
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2006-06       Impact factor: 3.802

5.  An online multi-channel SSVEP-based brain-computer interface using a canonical correlation analysis method.

Authors:  Guangyu Bin; Xiaorong Gao; Zheng Yan; Bo Hong; Shangkai Gao
Journal:  J Neural Eng       Date:  2009-06-03       Impact factor: 5.379

Review 6.  Steady-state visually evoked potentials: focus on essential paradigms and future perspectives.

Authors:  François-Benoît Vialatte; Monique Maurice; Justin Dauwels; Andrzej Cichocki
Journal:  Prog Neurobiol       Date:  2009-12-04       Impact factor: 11.685

7.  An evaluation of optic disc and nerve fiber layer examinations in monitoring progression of early glaucoma damage.

Authors:  H A Quigley; J Katz; R J Derick; D Gilbert; A Sommer
Journal:  Ophthalmology       Date:  1992-01       Impact factor: 12.079

Review 8.  Practical recommendations for measuring rates of visual field change in glaucoma.

Authors:  B C Chauhan; D F Garway-Heath; F J Goñi; L Rossetti; B Bengtsson; A C Viswanathan; A Heijl
Journal:  Br J Ophthalmol       Date:  2008-01-22       Impact factor: 4.638

9.  Generating visual flickers for eliciting robust steady-state visual evoked potentials at flexible frequencies using monitor refresh rate.

Authors:  Masaki Nakanishi; Yijun Wang; Yu-Te Wang; Yasue Mitsukura; Tzyy-Ping Jung
Journal:  PLoS One       Date:  2014-06-11       Impact factor: 3.240

10.  Assessing the feasibility of online SSVEP decoding in human walking using a consumer EEG headset.

Authors:  Yuan-Pin Lin; Yijun Wang; Tzyy-Ping Jung
Journal:  J Neuroeng Rehabil       Date:  2014-08-09       Impact factor: 4.262

View more
  12 in total

1.  Home perimetry. Is possible?

Authors:  F J Muñoz-Negrete; J Moreno-Montañés; G Rebolleda
Journal:  Arch Soc Esp Oftalmol (Engl Ed)       Date:  2021-05-15

Review 2.  Precision medicine to prevent glaucoma-related blindness.

Authors:  Sayoko E Moroi; David M Reed; David S Sanders; Ahmed Almazroa; Lawrence Kagemann; Neil Shah; Nakul Shekhawat; Julia E Richards
Journal:  Curr Opin Ophthalmol       Date:  2019-05       Impact factor: 3.761

3.  Preferential Loss of Contrast Decrement Responses in Human Glaucoma.

Authors:  Anthony M Norcia; Alexandra Yakovleva; Naz Jehangir; Jeffrey L Goldberg
Journal:  Invest Ophthalmol Vis Sci       Date:  2022-10-03       Impact factor: 4.925

Review 4.  Review of brain encoding and decoding mechanisms for EEG-based brain-computer interface.

Authors:  Lichao Xu; Minpeng Xu; Tzyy-Ping Jung; Dong Ming
Journal:  Cogn Neurodyn       Date:  2021-04-10       Impact factor: 3.473

5.  Rapid Campimetry-A Novel Screening Method for Glaucoma Diagnosis.

Authors:  Fabian Müller; Khaldoon O Al-Nosairy; Francie H Kramer; Christian Meltendorf; Nidele Djouoma; Hagen Thieme; Michael B Hoffmann; Friedrich Hoffmann
Journal:  J Clin Med       Date:  2022-04-12       Impact factor: 4.964

Review 6.  Novel Means of Clinical Visual Function Testing among Glaucoma Patients, Including Virtual Reality.

Authors:  Simon E Skalicky; George Yx Kong
Journal:  J Curr Glaucoma Pract       Date:  2019 Sep-Dec

7.  Comparison of head-mounted perimeter (imo®) and Humphrey Field Analyzer.

Authors:  Tairo Kimura; Chota Matsumoto; Hiroki Nomoto
Journal:  Clin Ophthalmol       Date:  2019-03-14

8.  Objective assessment of impulse control disorder in patients with Parkinson's disease using a low-cost LEGO-like EEG headset: a feasibility study.

Authors:  Yuan-Pin Lin; Hsing-Yi Liang; Yueh-Sheng Chen; Cheng-Hsien Lu; Yih-Ru Wu; Yung-Yee Chang; Wei-Che Lin
Journal:  J Neuroeng Rehabil       Date:  2021-07-02       Impact factor: 4.262

9.  Cost-efficient and Custom Electrode-holder Assembly Infrastructure for EEG Recordings.

Authors:  Yuan-Pin Lin; Ting-Yu Chen; Wei-Jen Chen
Journal:  Sensors (Basel)       Date:  2019-10-02       Impact factor: 3.576

10.  Usefulness of virtual reality-based training to diagnose strabismus.

Authors:  Hyun Sik Moon; Hyeon Jeong Yoon; Sang Woo Park; Chae Yeon Kim; Mu Seok Jeong; Sung Min Lim; Jee Heon Ryu; Hwan Heo
Journal:  Sci Rep       Date:  2021-03-15       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.