Literature DB >> 18585609

Imaging of bone transplants in the maxillofacial area by NewTom 9000 cone-beam computed tomography: a quality assessment.

Florian G Draenert1, Florian Gebhart, Christoph Neugebauer, Eva Coppenrath, Ulrich Mueller-Lisse.   

Abstract

OBJECTIVES: This study evaluates the definability and usability of bone transplant imaging with the NewTom 9000 cone-beam computed tomography (CBCT) device in a retrospective evaluation.
METHODS: CBCT data of 21 patients were analyzed in 2 steps. Step 1: transplants of cancellous bone (n = 6) and transplants of cortico-cancellous bone (n = 15). Step 2: The second group was further divided into nonvasculated transplants (n = 8) and microvascular transplants (n = 7). NewTom 9000 CBCT data sets were reconstructed and converted into DICOM data (spatial resolution: 0.25 mm, axial slice thickness: 0.3 mm). The OsiriX program was used to establish cross-sections in all 3 dimensions. Image quality assessment of the cross-sections was performed by 4 dentists.
RESULTS: CBCT scans of cortical bone transplants showed clear borders. All cancellous transplants were poorly defined and showed little x-ray contrast. In most cases these differences seen in the descriptive evaluation were not significant in the statistical analysis of the imaging quality assessment with Fisher's exact test.
CONCLUSIONS: Subjectively, the NewTom 9000 was considered by the authors to be of limited value for the evaluation of cancellous bone grafts, but to show good contrast for cortical bone grafts. The authors' subjective opinion was not supported by statistical analysis.

Entities:  

Mesh:

Year:  2008        PMID: 18585609     DOI: 10.1016/j.tripleo.2008.03.006

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  3 in total

1.  Comparison of cone-beam and conventional multislice computed tomography for image-guided dental implant planning.

Authors:  Paul W Poeschl; Nina Schmidt; Godoberto Guevara-Rojas; Rudolf Seemann; Rolf Ewers; Harald T Zipko; Kurt Schicho
Journal:  Clin Oral Investig       Date:  2012-03-14       Impact factor: 3.573

2.  Evaluation of demineralized bone and bone transplants in vitro and in vivo with cone beam computed tomography imaging.

Authors:  F G Draenert; F Gebhart; M Berthold; M Gosau; W Wagner
Journal:  Dentomaxillofac Radiol       Date:  2010-07       Impact factor: 2.419

3.  Calibrated segmentation of CBCT and CT images for digitization of dental prostheses.

Authors:  Veerle Wouters; Wouter Mollemans; Filip Schutyser
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-05-03       Impact factor: 2.924

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.